• Do not disassemble, crush, puncture, short external contacts, or dispose the battery in fire or water.
• If the server no longer automatically displays the correct date and time, then replace the battery that provides power
to the real-time clock. Under normal use, battery life is 5 to 10 years.
Removing and replacing the system battery
Procedure
1.
2.
Disconnect all peripheral cables from the server.
3.
Remove the server from the chassis.
4.
5.
If a secondary riser option is installed,
6.
Do one of the following:
•
Remove the secondary riser blank.
•
Remove the secondary riser cage.
7.
Remove the primary riser cage.
8.
Locate the battery on the system board.
9.
Slightly push the metal tab, and then remove the system battery from the socket.
10. Slightly push the metal tab, and then install the new system battery in the socket.
68
Removal and replacement procedures
Содержание HPE ProLiant XL170r Gen10
Страница 6: ...Acronyms and abbreviations 128 6...
Страница 22: ...22 Customer self repair...
Страница 23: ...Customer self repair 23...
Страница 24: ...24 Customer self repair...
Страница 95: ...InfiniBand and auxiliary adapter cabling Cable color Description Orange White cable Blue Black cable Cabling 95...