background image

7. Remove the HPE Persistent Memory module.

8. Install the new HPE Persistent Memory module, and review the persistent memory configuration of the server.

For more information, see 

Configuring the server for HPE Persistent Memory.

9. If you are relocating the HPE Persistent Memory module to or from another server, see the HPE Persistent Memory

module relocation guidelines.

HPE Persistent Memory module-processor compatibility

HPE Persistent Memory modules are supported only in servers with second-generation Intel Xeon Scalable processors
installed.

Configuring the server for HPE Persistent Memory

After installing HPE Persistent Memory modules, configure the server for HPE Persistent Memory.

IMPORTANT: Always follow recommendations from your software application provider for high-availability best
practices to ensure maximum uptime and data protection.

A number of configuration tools are available, including:

• UEFI System Utilities—Access System Utilities through the Remote Console to configure the server by pressing the 

F9

key during POST.

• iLO RESTful API—Use the iLO RESTful API through tools such as the RESTful Interface Tool (ilorest) or other third-

party tools.

• HPE Persistent Memory Management Utility—The HPE Persistent Memory Management Utility is a desktop

application used to configure the server for HPE Persistent Memory, as well as evaluate and monitor the server
memory configuration layout.

For more information, see the HPE Persistent Memory User Guide on the Hewlett Packard Enterprise website (

https://

www.hpe.com/info/persistentmemory-docs).

HPE Persistent Memory module relocation guidelines

Observe the relocation guidelines when doing the following:

60

Removal and replacement procedures

Содержание HPE ProLiant XL170r Gen10

Страница 1: ...tion and maintenance procedures diagnostic tools specifications and requirements for hardware components and software This guide is for an experienced service technician Hewlett Packard Enterprise ass...

Страница 2: ...lid license from Hewlett Packard Enterprise required for possession use or copying Consistent with FAR 12 211 and 12 212 Commercial Computer Software Computer Software Documentation and Technical Data...

Страница 3: ...ler spare parts 14 Media Module adapter spare parts 14 HPE Trusted Platform Module 2 0 spare part 14 SUV cable spare part 15 OPA adapter cable spare kit 15 Smart Array controller cable spare part 15 C...

Страница 4: ...module 59 HPE Persistent Memory module processor compatibility 60 Configuring the server for HPE Persistent Memory 60 HPE Persistent Memory module relocation guidelines 60 HPE Persistent Memory module...

Страница 5: ...Smart Array controller cables 90 Onboard S100i SR Gen10 controller cabling SATA only 91 Smart Array type p controller cabling SAS SATA 91 Storage controller backup power cabling 92 Secondary riser ca...

Страница 6: ...Acronyms and abbreviations 128 6...

Страница 7: ...terprise PartSurfer website Item Description 1 Air baffle spare part Air baffle spare part Customer self repair Mandatory Description Spare part number Air baffle 879858 001 System components Hewlett...

Страница 8: ...Processor spare parts First generation Intel Xeon Scalable Processor spare parts Customer self repair No Description Spare part number Intel Xeon Bronze series processors 1 70 GHz Intel Xeon Bronze 31...

Страница 9: ...875722 001 2 60 GHz Intel Xeon Gold 6142 16C 150 W 874733 001 3 00 GHz Intel Xeon Gold 6136 12C 150 W 875724 001 3 20 GHz Intel Xeon Gold 6134 8C 130 W 875723 001 3 40 GHz Intel Xeon Gold 6128 6C 115...

Страница 10: ...tel Xeon Gold 5215 10C 85 W P11610 001 2 50 GHz Intel Xeon Gold 6248 20C 150 W P11618 001 2 60 GHz Intel Xeon Gold 6240 18C 150 W P11615 001 2 70 GHz Intel Xeon Gold 6226 12C 125 W P12008 001 2 80 GHz...

Страница 11: ...rank x4 PC4 2933Y R P06189 001 64 GB dual rank x4 PC4 2933Y R P06192 001 64 GB quad rank x4 PC4 2933Y L P06190 001 128 GB dual rank x4 PC4 2933Y L P06191 001 HPE Persistent Memory module spare parts...

Страница 12: ...le for servers 1 and 2 in the Apollo r2600 Gen10 Chassis Apollo r2800 Gen10 Chassis 1U server NVMe cable 2U server NVMe cable 879840 001 Server options Hewlett Packard Enterprise continually improves...

Страница 13: ...tional Description Spare part number FlexibleLOM riser board 879854 001 Secondary riser board for processor 1 879856 001 Secondary riser board for processor 2 879857 001 Primary riser board spare part...

Страница 14: ...e kit P10330 001 Ethernet adapter spare part Customer self repair Optional Description Spare part number HPE Ethernet 100Gb 1P 842QSFP28 Adapter 877697 001 Smart Array controller spare parts Customer...

Страница 15: ...acing the SUV cable OPA adapter cable spare kit Customer self repair Optional Description Spare part number OPA adapter sideband cable OPA adapter IFP cable P01290 001 Smart Array controller cable spa...

Страница 16: ...rprise within a defined period of time normally five 5 business days The defective part must be returned with the associated documentation in the provided shipping material Failure to return the defec...

Страница 17: ...tamente dal cliente CSR Customer Self Repair Se in fase di diagnostica Hewlett Packard Enterprise o un centro di servizi o di assistenza Hewlett Packard Enterprise identifica il guasto come riparabile...

Страница 18: ...rziel am folgenden Gesch ftstag geliefert F r bestimmte Standorte ist eine Lieferung am selben Tag oder innerhalb von vier Stunden gegen einen Aufpreis verf gbar Wenn Sie Hilfe ben tigen k nnen Sie da...

Страница 19: ...aquellos casos en los que sea necesario devolver alg n componente a Hewlett Packard Enterprise deber hacerlo en el periodo de tiempo especificado normalmente cinco d as laborables Los componentes def...

Страница 20: ...meer informatie over het Customer Self Repair programma van Hewlett Packard Enterprise Informatie over Service Partners vindt u op de Hewlett Packard Enterprise website Garantieservice Parts Only Het...

Страница 21: ...Packard Enterprise paga todas as despesas de transporte e de devolu o da pe a e determina a transportadora servi o postal a ser utilizado Para obter mais informa es sobre o programa de reparo feito pe...

Страница 22: ...22 Customer self repair...

Страница 23: ...Customer self repair 23...

Страница 24: ...24 Customer self repair...

Страница 25: ...ded surface before removing them from their containers Avoid touching pins leads or circuitry Always be properly grounded when touching a static sensitive component or assembly Server warnings and cau...

Страница 26: ...le power supply This device protects the hardware from damage caused by power surges and voltage spikes and keeps the system in operation during a power failure CAUTION Do not operate the server for l...

Страница 27: ...ng down the server for any upgrade or maintenance procedures perform a backup of critical server data and programs IMPORTANT When the server is in standby mode auxiliary power is still being provided...

Страница 28: ...er to carry the server or server blank Procedure 1 Power down the server 2 Disconnect all peripheral cables from the server 3 Remove the server from the chassis a Loosen the release lever thumbscrew b...

Страница 29: ...ewdriver available Procedure 1 Power down the server 2 Disconnect all peripheral cables from the server 3 Remove the server from the chassis 4 Remove the air baffle 5 Remove the bayonet board a Remove...

Страница 30: ...ooling and thermal damage do not operate the server unless either riser blank or riser cage is installed Prerequisites Before you perform this procedure make sure that you have a T 10 Torx screwdriver...

Страница 31: ...e make sure that you have a T 10 Torx screwdriver available Procedure 1 Power down the server 2 Disconnect all peripheral cables from the server 3 Remove the server from the chassis 4 Remove the air b...

Страница 32: ...re make sure that you have a T 10 Torx screwdriver available Procedure 1 Power down the server 2 Disconnect all peripheral cables from the server 3 Remove the server from the chassis 4 If a secondary...

Страница 33: ...nect all peripheral cables from the server 3 Remove the server from the chassis 4 Remove the air baffle 5 If a secondary riser option is installed remove the bayonet board 6 Do one of the following Re...

Страница 34: ...ure make sure that you have a T 10 Torx screwdriver available Procedure 1 Install the primary riser blank 2 Do one of the following Install the secondary riser blank Install the secondary riser cage 3...

Страница 35: ...ly seated in its system board the connector 2 Do one of the following Install the secondary riser blank Install the secondary riser cage 3 If removed install the bayonet board 4 If removed install the...

Страница 36: ...ver 4 Power up the server Install the secondary riser cage Prerequisites Before you perform this procedure make sure that you have a T 10 Torx screwdriver available Procedure 1 Install the secondary r...

Страница 37: ...p the server Install the bayonet board Prerequisites Before you perform this procedure make sure that you have a T 10 Torx screwdriver available Procedure 1 Install the bayonet board a Connect all the...

Страница 38: ...c Install the bayonet board cover and then install the screws to secure it to the server tray d Install the screws to secure the cover to the bayonet board 38 Removal and replacement procedures...

Страница 39: ...onnect all peripheral cables to the server 5 Power up the server Install the air baffle Procedure 1 Install the air baffle 2 Install the server into the chassis 3 Connect all peripheral cables to the...

Страница 40: ...lever thumbscrew 4 Connect all peripheral cables to the server 5 Power up the server Power up the server The SL XL chassis firmware initiates an automatic power up sequence when the servers are insta...

Страница 41: ...re 1 Disconnect the peripheral devices connected to the SUV cable 2 Disconnect the SUV cable a Press and hold both sides of the SUV connector b Disconnect the cable from the SUV port To replace the co...

Страница 42: ...PCA components due to a perceived hardware error make sure first that the component is firmly seated in the slot Do not bend or flex circuit boards when reseating components Prerequisites Before you p...

Страница 43: ...has internal cabling disconnect these internal cables from the expansion board 7 Remove an expansion board Primary riser cage Secondary riser cage 8 If you do not intend to replace the expansion boar...

Страница 44: ...y card An HPE InfiniBand HDR Ethernet 200 GB 1 port 940QSFP56 x16 adapter is installed in slot 1 and auxiliary card is installed in slot 2 Prerequisites Before you perform this procedure make sure tha...

Страница 45: ...iser cage 8 Remove the auxiliary card from slot 2 Retain the secondary riser retention cover and screw for future use 9 Disconnect the cables from the auxiliary card a Open the retention clip and slid...

Страница 46: ...step 9 To replace the component 1 If installed remove the full height bracket from the adapter Retain the full height bracket and screws for future use 2 Install the low profile bracket provided in t...

Страница 47: ...e and black cables from the auxiliary card connect to the adapter board ports labeled WHITE CABLE and BLACK CABLE respectively The cable latch door must be open when connecting the cables Close the ca...

Страница 48: ...sily damaged To avoid damaging the connector pins do not use excessive force when connecting the cables 5 Push the clip down and slide the cable retention clip on the adapter 6 Install the adapter in...

Страница 49: ...rd in slot 2 11 Install the secondary riser cage 12 Install the bayonet board 13 Install the air baffle 14 Install the server into the chassis 15 Connect all peripheral cables to the server 16 Connect...

Страница 50: ...might be necessary to limit the number of drives installed in the chassis For more information see List of components with temperature requirements Procedure 1 Power down the server 2 Disconnect all p...

Страница 51: ...dware error make sure first that the component is firmly seated in the slot Do not bend or flex circuit boards when reseating components Prerequisites Before you perform this procedure make sure that...

Страница 52: ...secondary riser board CAUTION Before replacing a DIMM expansion board or other similar PCA components due to a perceived hardware error make sure first that the component is firmly seated in the slot...

Страница 53: ...board 7 If present disconnect the storage controller backup power cables from the riser board 8 Remove the riser board Secondary riser board for processor 1 Secondary riser board for processor 2 Flex...

Страница 54: ...rcuit boards when reseating components Prerequisites Before you perform this procedure make sure that you have a T 15 Torx and Phillips No 1 screwdrivers available Procedure 1 Power down the server 2...

Страница 55: ...6 Remove all installed M 2 SSDs from the riser board 7 If you do not intend to replace the M 2 SSD riser board install the DIMM guard Removal and replacement procedures 55...

Страница 56: ...erequisites Before you perform this procedure make sure that you have a T 15 Torx screwdriver available Procedure 1 Power down the server 2 Disconnect all peripheral cables from the server 3 Remove th...

Страница 57: ...8 Remove the Media Module adapter 9 If you do not intend to replace the adapter install the Media Module blank Removal and replacement procedures 57...

Страница 58: ...t supported Install either all DDR4 2666 DIMMs or all DDR4 2933 DIMMs in the server Removing and replacing a DIMM CAUTION Before replacing a DIMM expansion board or other similar PCA components due to...

Страница 59: ...following alerts CAUTION Electrostatic discharge can damage electronic components Be sure you are properly grounded before beginning this procedure CAUTION Failure to properly handle HPE Persistent Me...

Страница 60: ...plication provider for high availability best practices to ensure maximum uptime and data protection A number of configuration tools are available including UEFI System Utilities Access System Utiliti...

Страница 61: ...ing Manually back up the persistent memory data before relocating HPE Persistent Memory modules to another server Relocate the HPE Persistent Memory modules to another server Sanitize all HPE Persiste...

Страница 62: ...urrently user addressable such as bad blocks and over provisioned areas Purge Overwrite or erase all storage space that might have been used to store data using dedicated device sanitize commands such...

Страница 63: ...emove the server from the chassis 4 Remove the bayonet board 5 Do one of the following Remove the secondary riser blank Remove the secondary riser cage 6 Do one the following Remove the primary riser...

Страница 64: ...on a work surface with the processor facing up e Install the dust cover 12 Remove the system board Replacing the system board Prerequisites Before you perform this procedure make sure that you have a...

Страница 65: ...until it sits evenly on the socket The heatsink alignment posts are keyed The processor will only install one way A standard heatsink is shown your heatsink might look different CAUTION Be sure to ti...

Страница 66: ...peripheral cables to the server 9 Power up the server 10 Access System Utilities and Re enter the server serial number and product ID If the server is using Intel Xeon Gold 6244 processors select an...

Страница 67: ...server is using Intel Xeon Gold 6244 processors do the following a Select System Configuration BIOS Platform Configuration RBSU Advanced Options Fan and Thermal Options Thermal Configuration b Select...

Страница 68: ...server 2 Disconnect all peripheral cables from the server 3 Remove the server from the chassis 4 Remove the air baffle 5 If a secondary riser option is installed remove the bayonet board 6 Do one of...

Страница 69: ...ted Platform Module 2 0 Gen10 Option The HPE Trusted Platform Module 2 0 Gen10 Option is not a customer removable part CAUTION If the TPM is removed from the original server and powered up on a differ...

Страница 70: ...he iLO Virtual NMI feature Troubleshooting resources Troubleshooting resources are available for HPE Gen10 server products in the following documents Troubleshooting Guide for HPE ProLiant Gen10 serve...

Страница 71: ...ure Boot that enables the system firmware option card firmware operating systems and software collaborate to enhance platform security UEFI Graphical User Interface GUI An Embedded UEFI Shell that pro...

Страница 72: ...l signature to execute during the boot process Operating systems must support Secure Boot and have an EFI boot loader signed with one of the authorized keys to boot For more information about supporte...

Страница 73: ...er to change the mode that launches when you boot to F10 Intelligent Provisioning prepares the system for installing original licensed vendor media and Hewlett Packard Enterprise branded versions of O...

Страница 74: ...ystem Utilities HPE Smart Storage Administrator HPE SSA is the main tool for configuring arrays on HPE Smart Array SR controllers It exists in three interface formats the HPE SSA GUI the HPE SSA CLI a...

Страница 75: ...performance monitoring of Active Health System AHS and HPE iLO to optimize performance and predict and prevent problems Provides automatic collection and analysis of the sensor and telemetry data fro...

Страница 76: ...abled 2 The Media Module adapter is a hardware option Serial number iLO information pull tab The serial number iLO information pull tab is double sided One side shows the server serial number and the...

Страница 77: ...Flashing red System critical 4 Do not remove LED Flashing white Do not remove the server Removing the server may terminate the current operation and cause data loss Off The server can be removed 5 UI...

Страница 78: ...to locate a particular server when it is deployed in a dense chassis with other equipment Activating the UID LED helps an onsite technician to quickly identify a server for maintenance tasks UID butt...

Страница 79: ...exists Blinking amber 4 Hz blinking amber indicates a problem with the physical link Solid green A valid logical data activity link exists with no active traffic Blinking green A valid logical link e...

Страница 80: ...connector 3 13 x4 SATA port 14 System maintenance switch 15 x8 SATA port 16 Secondary PCIe x24 riser connector 2 17 TPM connector 18 microSD slot System maintenance switch descriptions Position Defaul...

Страница 81: ...nce switch position 6 is set to the On position and Secure Boot is enabled some configurations cannot be restored For more information see Secure Boot DIMM label identification To determine DIMM chara...

Страница 82: ...RDIMM LRDIMM V CAS 22 19 19 for 3DS TSV LRDIMM Y CAS 21 21 21 for RDIMM LRDIMM Y CAS 24 21 21 for 3DS TSV LRDIMM 7 DIMM type R RDIMM registered L LRDIMM load reduced E Unbuffered ECC UDIMM For more i...

Страница 83: ...128 GB 256 GB 512 GB 4 QR code Includes part number and serial number For more information about product features specifications options configurations and compatibility see the product QuickSpecs on...

Страница 84: ...ard components This section identifies the riser slots compatible with specific types of expansion options supported by the server The following riser options are supported Primary riser Secondary ris...

Страница 85: ...adapter1 InfiniBand adapter 2 Storage controller backup power connector 1 Intel Omni Path Architecture Secondary riser board components The server supports multiple riser options in the secondary pos...

Страница 86: ...ions 1 Storage controller backup power connector 2 2 PCIe3 x16 16 8 4 1 Smart Array type p controller Low profile expansion boards Auxiliary adapter P2 secondary riser board components Processor 2 is...

Страница 87: ...nnector 2 2 PCIe3 x16 16 8 4 1 Smart Array type p controller Low profile expansion boards Auxiliary adapter P1 P2 secondary riser port numbering M 2 SSD riser bay numbering The arrow points toward the...

Страница 88: ...940QSFP56 x16 adapter component Item Description 1 QSFP56 port 2 Black cable connector 3 White cable connector HPE InfiniBand HDR PCIe G3 Auxiliary card Item Description 1 Black cable connector 2 Whit...

Страница 89: ...ce to verify the length of the cable Use the internal cable management features to properly route and secure the cables When routing cables be sure that the cables are not in a position where they can...

Страница 90: ...s Controller type Cable kit part number Cable part number From To port Embedded controller 874305 B21 870527 001 System board Bayonet port Type p standup plug in controller 874785 B211 870539 001 Cont...

Страница 91: ...Onboard S100i SR Gen10 controller cabling SATA only Smart Array type p controller cabling SAS SATA Smart Array type p controller cabling in the primary riser slot Cabling 91...

Страница 92: ...oller cabling in the secondary riser slot Storage controller backup power cabling Storage controller backup power cabling in the primary riser slot Storage controller backup power cabling in the P1 se...

Страница 93: ...4 B21 870531 0011 Riser port 1 or 2 Bayonet port 1 or 2 870532 0012 1 The 870531 001 cable included in the 874304 B21 cable kit is a 16NVMe long cable 2 The 870532 001 cable included in the 874304 B21...

Страница 94: ...FlexibleLOM riser cabling OPA adapter cabling Cable color Description Blue OPA adapter sideband cable Orange OPA adapter IFP cable 94 Cabling...

Страница 95: ...InfiniBand and auxiliary adapter cabling Cable color Description Orange White cable Blue Black cable Cabling 95...

Страница 96: ...41 F to 50 F and 35 C to 40 C 95 F to 104 F at sea level with an altitude derating of 1 0 C per every 175 m 1 8 F per every 574 ft above 900 m 2953 ft to a maximum of 3050 m 10 000 ft 40 C to 45 C 104...

Страница 97: ...led Thermal limitations for components in systems with the Enhanced Processor Performance feature disabled The following drive options have drive capacities greater than or equal to 10 TB but their th...

Страница 98: ...AS expander Redundant and nonredundant 0 to 24 drives 30 C 86 F Apollo r2800 Gen10 Chassis 16 NVMe backplane Redundant and nonredundant 0 to 4 drives 30 C 86 F Intel Xeon Gold 6244 Apollo r2200 Gen10...

Страница 99: ...lled in drive bays 1 2 and 2 2 Similarly if the component is installed in server 3 or server 4 and the server is installed in the Apollo r2200 Gen10 Chassis drive blanks must be installed in drive bay...

Страница 100: ...35 C 95 F Apollo r2800 Gen10 Chassis 24 SFF backplane with SAS expander Redundant 0 to 24 drives 35 C 95 F Apollo r2800 Gen10 Chassis 16 NVMe backplane Redundant 0 to 4 drives 35 C 95 F 128 GB LRDIMM...

Страница 101: ...st be installed in drive bays 1 2 and 2 2 Similarly if the component is installed in server 3 or server 4 and the server is installed in the Apollo r2200 Gen10 Chassis drive blanks must be installed i...

Страница 102: ...n10 Chassis 16 NVMe backplane Redundant and nonredundant 0 to 4 drives Not supported P408e p Controller1 Apollo r2200 Gen10 Chassis 12 LFF backplane Redundant and nonredundant 3 drives2 Not supported...

Страница 103: ...Redundant and nonredundant 3 drives2 28 C 82 4 F 3 drives3 Not supported 0 to 2 drives4 35 C 95 F Apollo r2600 Gen10 Chassis 24 SFF or 16 SFF 8 NVMe backplane Redundant and nonredundant 0 to 6 drives...

Страница 104: ...t supported 3 drives2 Not supported 0 to 2 drives3 22 C 71 F Apollo r2600 Gen10 Chassis 24 SFF or 16 SFF 8 NVMe backplane Redundant and nonredundant 0 to 6 drives Not supported Apollo r2800 Gen10 Chas...

Страница 105: ...or server 4 and the server is installed in the Apollo r2200 Gen10 Chassis drive blanks must be installed in drive bays 3 2 and 4 2 Ethernet and InfiniBand adapters Description Chassis Fan configuratio...

Страница 106: ...24 SFF or 16 SFF 8 NVMe backplane Redundant and nonredundant 0 to 6 drives Optical cable Not supported Copper cable 28 C 82 4 F Apollo r2800 Gen10 Chassis 24 SFF backplane with SAS expander Redundant...

Страница 107: ...940QSFP56 Apollo r2200 Gen10 Chassis 12 LFF backplane Redundant and nonredundant 3 drives1 Not supported 3 drives2 Not supported 0 to 2 drives3 Not supported 0 to 2 drives4 Optical cable 22 C 71 6 F C...

Страница 108: ...2 Similarly if the component is installed in server 3 or server 4 and the server is installed in the Apollo r2200 Gen10 Chassis drive blanks must be installed in drive bays 3 2 and 4 2 4 If the compon...

Страница 109: ...es Optical cable Not supported Copper cable 30 C 86 F 1 The drive capacity must be less than 10 TB 2 The drive capacity must be greater than or equal to 10 TB 3 If the component is installed in server...

Страница 110: ...ckplane with SAS expander Redundant and nonredundant 0 to 24 drives 30 C 86 F Apollo r2800 Gen10 Chassis 16 NVMe backplane Redundant and nonredundant 0 to 4 drives 30 C 86 F 1 The drive capacity must...

Страница 111: ...ives2 25 C 77 F 0 to 2 drives3 35 C 95 F Apollo r2600 Gen10 Chassis 24 SFF or 16 SFF 8 NVMe backplane Redundant and nonredundant 0 to 6 drives 35 C 95 F Apollo r2800 Gen10 Chassis 24 SFF backplane wit...

Страница 112: ...alled in server 3 or server 4 and the server is installed in the Apollo r2200 Gen10 Chassis drive blanks must be installed in drive bays 3 2 and 4 2 DIMMs In nonredundant fan mode the 32 GB RDIMM 64 G...

Страница 113: ...r2800 Gen10 Chassis 16 NVMe backplane Redundant 0 to 4 drives 35 C 95 F 128 GB LRDIMM Apollo r2200 Gen10 Chassis 12 LFF backplane Redundant 3 drives1 Not supported 3 drives2 Not supported 0 to 2 driv...

Страница 114: ...server 1 or server 2 and the server is installed in the Apollo r2200 Gen10 Chassis bezel blanks must be installed in drive bays 1 2 and 2 2 Similarly if the component is installed in server 3 or serve...

Страница 115: ...ler Apollo r2200 Gen10 Chassis 12 LFF backplane Redundant and nonredundant 3 drives1 22 C 71 6 F 3 drives2 22 C 71 6 F 0 to 2 drives3 30 C 86 F Apollo r2600 Gen10 Chassis 24 SFF or 16 SFF 8 NVMe backp...

Страница 116: ...r2600 Gen10 Chassis 24 SFF or 16 SFF 8 NVMe backplane Redundant and nonredundant 0 to 6 drives 35 C 95 F Apollo r2800 Gen10 Chassis 24 SFF backplane with SAS expander Redundant and nonredundant 0 to...

Страница 117: ...10 Chassis 24 SFF backplane with SAS expander Redundant and nonredundant 0 to 24 drives 25 C 77 F Apollo r2800 Gen10 Chassis 16 NVMe backplane Redundant and nonredundant 0 to 4 drives 25 C 77 F CNA Ap...

Страница 118: ...he server is installed in the Apollo r2200 Gen10 Chassis drive blanks must be installed in drive bays 3 2 and 4 2 Ethernet and InfiniBand adapters Description Chassis Fan configuration Number of drive...

Страница 119: ...2600 Gen10 Chassis 24 SFF or 16 SFF 8 NVMe backplane Redundant and nonredundant 0 to 6 drives Optical cable 22 C 71 6 F Copper cable 35 C 95 F Apollo r2800 Gen10 Chassis 24 SFF backplane with SAS expa...

Страница 120: ...drives1 Not supported 3 drives2 Not supported 0 to 2 drives3 Not supported 0 to 2 drives4 Optical cable 25 C 77 F Copper cable 35 C 95 F Apollo r2600 Gen10 Chassis 24 SFF or 16 SFF 8 NVMe backplane Re...

Страница 121: ...server is installed in the Apollo r2200 Gen10 Chassis drive blanks must be installed in drive bays 3 2 and 4 2 4 If the component is installed in server 1 or server 2 and the server is installed in t...

Страница 122: ...Gen10 Chassis 16 NVMe backplane Redundant and nonredundant 0 to 4 drives Optical cable 25 C 77 F Copper cable 35 C 95 F 1 The drive capacity must be less than 10 TB 2 The drive capacity must be great...

Страница 123: ...Apollo r2600 Gen10 Chassis 24 SFF or 16 SFF 8 NVMe backplane Redundant and nonredundant 0 to 6 drives 30 C 86 F Apollo r2800 Gen10 Chassis 24 SFF backplane with SAS expander Redundant and nonredundant...

Страница 124: ...OCK Storage compatibility matrix www hpe com storage spock Storage white papers and analyst reports www hpe com storage whitepapers For additional general support websites see Support and other resour...

Страница 125: ...essing updates Some software products provide a mechanism for accessing software updates through the product interface Review your product documentation to identify the recommended software update met...

Страница 126: ...d on your product s service level Hewlett Packard Enterprise strongly recommends that you register your device for remote support If your product includes additional remote support details use search...

Страница 127: ...ormation report for this product can be found at https www hpe com info reach For Hewlett Packard Enterprise product environmental and safety information and compliance data including RoHS and REACH s...

Страница 128: ...tform Management HPE SSA HPE Smart Storage Administrator iLO Integrated Lights Out IML Integrated Management Log ISO International Organization for Standardization IFP Internal faceplate to processor...

Страница 129: ...ack Consolidation Management RoHS Restriction of Hazardous Substances SAS serial attached SCSI SATA serial ATA SFF small form factor SPP Service Pack for ProLiant UEFI Unified Extensible Firmware Inte...

Отзывы: