5. Do one of the following:
•
Remove the secondary riser blank.
•
Remove the secondary riser cage.
6. Remove the primary riser cage.
7. If installed, remove the expansion board from the riser board.
8. If present, disconnect the storage controller backup power cable from the riser board.
9. Remove the primary riser board.
To replace the component, reverse the removal procedure.
Removing and replacing the secondary riser board
CAUTION: Before replacing a DIMM, expansion board, or other similar PCA components due to a perceived
hardware error, make sure first that the component is firmly seated in the slot. Do not bend or flex circuit boards
when reseating components.
Prerequisites
Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available.
Procedure
2. Disconnect all peripheral cables from the server.
3. Remove the server from the chassis.
5. Remove the secondary riser cage.
52
Removal and replacement procedures