Hewalex KS2100F Скачать руководство пользователя страница 5

EN

* does not apply to options: Am, TAC

INSTALLATION GUIDE - FLAT PLATE SOLAR COLLECTORS

KS2100F / KS2200F / KS2400F / KS2600F

Fig.1. 

Explanatory drawing of the collector (dimensions)

TECHNICAL DATA

  1    

.2016

22.12

2

PURPOSE

1

Collectors are used for:

3

•   heating domestic hot water
•   supporting space heating 
•   heating pool water 
•   supporting industrial processes 

Pressure drop*, mbar

* Value of the pressure drop at nominal flow, rate for aqueous propylene glycol solution at concentration of 44% 
and temperature of  40°C.

Recommended flow rate per collector, 
l/min

(minimum / 

nominal

 / maximum)

 

Collector

Dimensions, mm:

2

Total area, m

2

Aperture area, m

Weight (without fluid), kg

Liquid capacity, l

Max. operating pressure, bar

L

W

H

(see Fig. 1.)

TRANSPORT AND STORAGE

Collectors are transported in a lying position, the glass upwards. The maximum of 15 pieces of collectors can be 
stacked on a wooden pallet. Collectors without the factory packaging are stacked on the pads. Transportation of 
collectors in a standing position. That is, the short side horizontally, is allowed only when having the pallet full of 
collectors or when having solar sets factory packaged. During transport protect the collectors from moving.

H

L

W

1,2 / 

1,8 

/

 

2,5 

1,3 / 

2,0

 / 2,8 

16

15

16

16,5

KS2100F

KS2200F

KS2400F

KS2600F

2022

1019 

90 

2,06 

1,93

35 

0,85

10

 

2022 

1111 

90 

2,25

2,11

38 

0,92

10 

2022

1203

90 

2,43

2,29

40 

1,00

10

2022 

1219 

 90 

2,62 

2,47 

43 

1,09

10  

1,5 / 

2,2

 / 3,0 

Содержание KS2100F

Страница 1: ...w pozycji le cej szyb do g ry Stosy kolektor w uk adane na paletach drewnianych mog liczy maksymalnie 15 sztuk Kolektory bez opakowa fabrycznych uk ada na przek adkach Transport kolektor w w pozycji...

Страница 2: ...e zawartych w instrukcjach do czonych do mocowa Budowa kolektora s onecznego i systemu monta owego zapewnia odporno na ci nienie wiatru i obci enie niegiem co najmniej 1000 Pa UWAGA Monta na nieodpowi...

Страница 3: ...ktor w w cza w obieg rur elastyczn lub sztywn z zastosowaniem odpowiedniej kompensacji W obiegach solarnych stosowa rury z nast puj cych materia w mied stal nierdzewna stal w glowa Stosowa odpowiedni...

Страница 4: ...zy czeniowego grozi trwa ym uszkodzeniem kolektora Instalacj nape nia tylko przy braku bezpo redniego promieniowania s onecznego lub gdy kolektor jest os oni ty W czasie nape niania instalacji zachowa...

Страница 5: ...2 Aperture area m Weight without fluid kg Liquid capacity l Max operating pressure bar L W H see Fig 1 TRANSPORT AND STORAGE Collectors are transported in a lying position the glass upwards The maxim...

Страница 6: ...ounting one should be guided by available installation options recommended orientation of the collectors and the base type Follow the recommendations that are provided with the mounting systems The co...

Страница 7: ...should be connected to installation either through elastic tubes or rigid pipes in case of the latter adequate compensation should be used In solar circuits one should use pipes of the following mater...

Страница 8: ...l Nuts of the collector s connections are to be tightened until a slight resistance is felt max 5 Nm 3 7 lb ft Overtighteningtheconnectionmayresultinapermanentdamageofthecollector Installationshouldno...

Страница 9: ...RU Am TAC KS2100F KS2200F KS2400F KS2600F 1 2 2 1 2016 22 12 2 1 3 15 1 44 40 C KS2100F KS2200F KS2400F KS2600F 2022 1019 90 2 06 1 93 35 0 85 10 2022 1111 90 2 25 2 11 38 0 92 10 2022 1203 90 2 43 2...

Страница 10: ...2 22 12 2016 4 1000 4 1 4 2 5 90 90 90 A B 90 45 S 45 90 30 45...

Страница 11: ...DN15 DN20 DN25 KS2100F KS2200F KS2400F KS2600F 1 4 1 3 1 3 5 8 4 7 4 6 9 12 8 10 7 9 A B C D E 4 3 4 4 3 22 12 2016 B a b D a 8 a b 8 a 8 a 8 b 8 a 5...

Страница 12: ...4 6 5 5 4 22 12 2016 4 5 TERMSOL EKO CORACON SOL 5F...

Страница 13: ...pile di collettori sistemati sui pallet di legno possono essere al massimo di 15 pezzi I collettori senza l imballaggio originale vanno impilati con distanziatori Il trasporto dei collettori in posiz...

Страница 14: ...ndicazioni contenute nelle istruzioni allegate ai fissaggi La costruzione del collettore solare e sistema di montaggio forniscono resistenza alla pressione del vento e carico di neve min 1000 Pa ATTEN...

Страница 15: ...ie applicare i regolatori di portata Connessione D non permette lo svuotamento dei collettori dal glicole ATTENZIONE Unire i collettori in batteria con l uso degli originali kit di connessione disponi...

Страница 16: ...materialenontrasparente Riempirel impiantosoloinmancanzadiradiazionesolaredirettaoquandoilcollettore coperto Durante il riempimento dell impianto osservare tutte le precauzioni consigliate dal produtt...

Страница 17: ...rdern Auf Holzpaletten d rfen maximal bis zu 15 Kollektoren bereinander gestapelt werden Kollektoren ohne Herstellerverpackung sind auf Zwischenlagen zu stapeln Der Transport von Kollektoren in der s...

Страница 18: ...en Sie die Empfehlungen der den Befestigungen beigef gten Anleitungen ein Der Aufbau des Solar Kollektors und einem Befestigungssystem sorgen Widerstand gegen Winddruck und Schneelast von 1000 Pa min...

Страница 19: ...n Verbindung D macht kein Entleeren der Kollektoren vom W rmetr germedium m glich ACHTUNG Die Kollektoren sind mithilfe der Original Anschlusssets in Batterien zu verbinden die im Herstellerangebot er...

Страница 20: ...hrtzunichtwiedergutzumachendenInnensch dendesKollektors Die Installation darf nur bei Mangel an direkter Sonneneinstrahlung bzw wenn der Kollektor abgedeckt ist gef llt werden W hrend der Auff lldaue...

Страница 21: ...nsporter les collecteurs dans la position horizontale le verre vers le haut Des piles de collecteurs stock es sur des palettes en bois peuvent compter jusqu 15 unit s Mettre les collecteurs sans embal...

Страница 22: ...prescriptions dans les notices des supports La construction du collecteur solaire et du syst me de montage offre une r sistance la pression du vent et la charge de neige de min 1000 Pa ATTENTION Le m...

Страница 23: ...r gulateurs de d bit La liaison D ne permet pas la vidange de l agent du collecteur ATTENTION Relier les collecteurs en batteries en utilisant les ensembles de connexion d origine disponibles chez le...

Страница 24: ...xionpeutcauserdesdommagespermanentsaucollecteur Remplirlesyst meuniquementenl absencedelalumi redirectedusoleiloulorsquelecollecteurestcouvert Pendant le remplissage du syst me garder toutes les pr ca...

Отзывы: