1. Be sure that all safety measures required by the
equipment manufacturer have been followed.
2. Turn on power to the receiver. The CPU Standby
LED (1) should flash yellow to indicate the
microprocessor is working properly.
3. Place the key switch on the transmitter in the
OFF position and the E-Stop pushbutton in the
OFF position (i.e. twist and pull it out).
4. Place a fully charged battery pack into the battery
compartment located at the back of the
transmitter.
5. Turn the key switch to the ON position. The
Power LED on the transmitter flashes GREEN
once and an acoustic pulse sounds to indicate
there is a diagnostic test in progress.The LED on
the transmitter continuously flashes GREEN and
a second acoustic pulse sounds to indicate
successful diagnostic testing.
6. Immediately following the diagnostic test, the
Receiver Transmission LED (2) should flash. This
indicates that the receiver is detecting a valid
signal from the transmitter.
7. Twist and pull out the E-Stop pushbutton. The
Receiver E-Stop Relay LED (5) should illuminate.
8. Push in the E-Stop pushbutton. The E-Stop Relay
LED should go off.
9. Twist and pull out the E-Stop pushbutton.
10. Press the Start/horn pushbutton on the
transmitter. The Start Relay LED should
illuminate. The main line contactor will activate at
this time (depending on crane wiring).
11. Activate the motion joysticks to test the
crane/machine functions.
IMPORTANT:
The crane/machine functions will
operate during this check. Be certain that there are no
obstacles near the crane/machine.
12. Confirm that the crane/machine moves
appropriately and that the correct LEDs illuminate
for each crane/machine motion.
13. Activate the Option pushbutton and Selector
toggle switch to test optional crane/machine
functions.
14. Push in the E-Stop pushbutton and turn the key
switch to the OFF position. The E-stop and relay
output LEDs in the receiver should turn off.
15. If transmitter and receiver function properly, the
system is ready for use.
16. Install the cover onto the receiver.
17. If the receiver or transmitter does not operate
properly, or if the crane/machine does not react
as directed, shut the entire system down and
refer to the Troubleshooting Section. If necessary,
contact Hetronic or your Dealer.
.
1 + 2
1
2
O
I
E-Stop Switch
Key
Switch
Power LED
Start/
Horn
Switch
WARNING:
The Receiver settings are set at
the factory and should be changed by
Hetronic service personnel only. Incorrectly
changing the settings of the receiver could
result in damage to equipment, serious injury
or death.
WARNING:
FAILURE TO FOLLOW
INSTRUCTIONS could result in personal
injury and/or damage to equipment. Read and
understand the safety instructions in all
manuals provided.
OPERATION