9

DK ASSIGNMENTS

Check the following list before turning on power to the 
receiver.

1. Be sure the motion toggle switches are in their 

Off (neutral) positions.

2. Be sure there are fully charged batteries in the 

transmitter. Refer to "Changing the Battery" on 
page 13.

HOLDING THE TRANSMITTER

Hold the transmitter with the control panel facing you. 
Be sure that you are able to easily read any text and 
understand operation symbols.

DK1

S1

DK2

DK7

DK8

S4

S5

DK9

DK10

DK5

DK6

S3

S2

DK3

DK4

S 0

S

to

p

HH-M-MFSHL TS5

S

to

p

DK1

DK2

DK3

DK4

DK5

DK6

DK7

DK8

DK10

S1

S2

S3

S4

S5

S6

DK11

DK12

HH-M-MFSHL TS6P

DK9

S 0

S

to

p

S

to

p

DK1

DK2

DK3

DK4

DK5

DK6

DK7

DK8

DK9

DK10

DK11

DK12

DK13

DK14

S1

S2

S3

S4

S5

S6

S7

HH-L-MFSHL TS7P

S

to

p

S

to

p

S 0

TEST PROCEDURES

WARNING: 

FAILURE TO FOLLOW 

INSTRUCTIONS could result in personal 
injury and/or damage to equipment. Read and 
understand the safety instructions in all 
manuals provided.

Testing or service must be performed by 
authorized personnel only.

There must be no load on the crane/machine.

Clear the crane/machine operating area of 
obstructions.

WARNING: 

FAILURE TO FOLLOW 

INSTRUCTIONS could result in personal 
injury and/or damage to equipment. Always 
hold the transmitter in the proper orientation. 
Holding the transmitter improperly while 
operating the crane/machine could result in 
unexpected crane/machine response.

PRELIMINAR

Y COPY

Содержание HH-L-MFSHL TS7P

Страница 1: ...r Avenue Halton Hills Ontario L7G 4X4 1 800 816 4459 Fax 1 905 702 0501 2005 Hetronic Inc All rights reserved No part of this publication may be reproduced transmitted transcribed stored in a retrieva...

Страница 2: ...er 6 Receiver Housing 7 External Antenna Installation 7 Standard Antenna Extension 7 Top Mount Antenna Extension 7 Connect Electrical Wiring 8 Quick Disconnect Plug 8 Quick Disconnect Plug Wire Termin...

Страница 3: ...arising out of the use of unauthorized replacement parts BEFORE ATTEMPTING TO OPERATE THIS SYSTEM 1 Make sure all installation has been properly completed 2 Understand all safety precautions provided...

Страница 4: ...ess code This code allows the operation of multiple systems in the same general vicinity The receiver only accepts commands from the transmitter with the same address code MFS Transmission Technology...

Страница 5: ...pment PRACTICES AND LAWS Practice usual and customary safe working precautions for the benefit of yourself and others Understand and follow all safety messages Be alert to unsafe conditions and the po...

Страница 6: ...e gases or liquids Receiver must be protected from ambient temperatures outside the range of 18 to 158 F 25 to 75 C Receiver Production Number Locate the Hetronic Production number decal on the receiv...

Страница 7: ...g 4 Insert the mounting screws through the holes in the housing block and tighten into the mounting surface 5 Bundle any excess antenna cable and secure with tie wraps or equivalent IMPORTANT DO NOT r...

Страница 8: ...system using the new H Link wireless technology These are preset at the factory and are password protected Refer to the HH MFSHL H Link Programming Manual for more details IMPORTANT The Address and F...

Страница 9: ...P DK9 S0 S t o p S t o p DK1 DK2 DK3 DK4 DK5 DK6 DK7 DK8 DK9 DK10 DK11 DK12 DK13 DK14 S1 S2 S3 S4 S5 S6 S7 HH L MFSHL TS7P S t o p S t o p S0 TEST PROCEDURES WARNING FAILURE TO FOLLOW INSTRUCTIONS cou...

Страница 10: ...cates that the E Stop contact is open crane machine motions will NOT operate The LED on the receiver should flash yellow 5 Activate the motion toggle switches There should be NO movement of the crane...

Страница 11: ...that the transmitter batteries are fully charged and inserted into the transmitter handle If any control is NOT in the Off neutral position when the battery is inserted the transmitter will not turn...

Страница 12: ...a switch is active when the batteries are inserted the unit will go into an error state The red LED will come on and stay on until the active switch is turned off LED DESCRIPTION Transmit Mode Green...

Страница 13: ...sposed of with typical refuse Contact a professional hazardous waste disposal service MAINTENANCE WARNING The transmitter will switch to the EMERGENCY STOP condition after the set amount of time expir...

Страница 14: ...fter normal start up procedure E Stop switch engaged Pull out E Stop switch Batteries fully discharged Check batteries to ensure a full charge Replace with new batteries if necessary No power to the r...

Страница 15: ...AA batteries Operation time Up to 500 hours Functions E Stop pushbutton 6 motion toggle switches Proportional grey code trigger switch Antenna Internal HH L MFSHL TS7P TRANSMITTER Weight 1 3 lbs 590g...

Страница 16: ...operator is responsible for understanding and following all safety precautions in this and other applicable operator manuals INSTALLATION AND SAFETY TEST DATA Crane machine Data Manufacturer Model Num...

Страница 17: ...the crane machine controls Maintained control The function activates when the control is placed in the ON position The function stops when the control is placed in the OFF position Momentary control T...

Страница 18: ...c Millisecond MHz Megahertz MOV Metal Oxide Varistor type of surge suppressor mW Milliwatt NiCd Nickel Cadmium NiMH Nickel Metal Hydride PLC Programmable logic controller PLL Phased locked loop PTO Pr...

Страница 19: ...any Company supplied items or materials List prices or discounts are subject to change without notice Quoted prices will be honored for a period of 90 days from the date of the written quotation unles...

Отзывы: