background image

8

CONNECT ELECTRICAL WIRING

Connect all remaining wires (power supply, engine 
start-stop, etc.) according to the wiring diagram of the 
crane/machine and the radio remote control.

Quick-Disconnect Plugs

Hetronic offers a plug receptacle kit, which contains 
two 12-pin quick-disconnect plugs with wedges and 28 
contacts. The installer must wire the female 
quick-disconnect plugs and terminate them to the 
crane/machine controls.

Quick-Disconnect Plug Wire Terminations

Refer to the wiring diagram on this page, which is also 
provided with your system.

The male and female connector module pins are 
labeled. The 12 pin connectors use numeric 
numbering, i.e. 1, 2, 3, 4, etc. 

Receiver Wiring Diagram and Pin Layout

Each Hetronic radio remote control system is delivered 
with two alkaline batteries. These are inserted in the 
battery compartment located in the handle of the 
transmitter. 

Please note that the actual configuration of each radio 
remote control system may vary from the illustrations 
shown in this manual. Refer to the technical 
documentation provided with each system for the 
actual design, layout and components.

FREQUENCY AND ADDRESS SETTINGS

Each Hetronic radio remote control system contains a 
radio frequency (RF) unit. Each system consists of a 
transmitter RF unit and a receiver RF unit.

Both Frequency and Address settings are uploaded to 
the system using the new H-Link wireless technology. 
These are preset at the factory and are password 
protected. Refer to the HH-MFSHL H-Link 
Programming Manual for more details.

IMPORTANT: 

 The Address and Frequency settings for 

both the transmitter and receiver must match; 
otherwise, the system will not function.

RRaaddiioo  RReem

moottee  RReecceeiivveerr

M

MFFSSH

HLL--D

DCC1166--PPW

WM

M

++11

22  //

  2244

VVDD

CC

CCoonnttrrooll

CCiirrccuuiitt

FF11  1100AA

KK00

GGNN

DD  

((--))

PPWW

MM

11

PPWW

MM

22

KK33

KK44

KK55

KK66

KK77

KK88

KK99

KK11

00

MM

CC

Inputs

AA

BB

KK11

11

KK11

22

KK11

33

KK11

44

UUBB

22

KK11

KK22

KK11

55

KK11

66

IINN

11

IINN

22

w

ww

ww

w..hheettrroonniicc..ccoom

m

BB77

BB66

BB44

BB55

BB33

AA

66

AA

77

AA

55

AA

88

AA

44

AA

99

AA

33

AA

1100

((A

A))

AA

22

AA

1111

AA

11

AA

1122

BB11

00

BB11

22

BB11

BB11

11

BB22

BB99

BB88

(A)

77

88

99

1100

1111

1122

66

55

44

33

22

11

11

22

33

44

55

66

1122

1111

1100

99

88

77

A

Addddrreessss

  LLeeaarrnn

HAND-HELD TRANSMITTERS

CAUTION: 

AVOID INJURY OR DAMAGE - 

Operating the transmitter without its antenna 
could destroy the final stage of the RF 
module. DO NOT attempt to change the 
Hetronic pre-set frequency or the 20-bit 
address. Personal injury and property 
damage could result from transmission 
interference and may void the warranty.

PRELIMINAR

Y COPY

Содержание HH-L-MFSHL TS7P

Страница 1: ...r Avenue Halton Hills Ontario L7G 4X4 1 800 816 4459 Fax 1 905 702 0501 2005 Hetronic Inc All rights reserved No part of this publication may be reproduced transmitted transcribed stored in a retrieva...

Страница 2: ...er 6 Receiver Housing 7 External Antenna Installation 7 Standard Antenna Extension 7 Top Mount Antenna Extension 7 Connect Electrical Wiring 8 Quick Disconnect Plug 8 Quick Disconnect Plug Wire Termin...

Страница 3: ...arising out of the use of unauthorized replacement parts BEFORE ATTEMPTING TO OPERATE THIS SYSTEM 1 Make sure all installation has been properly completed 2 Understand all safety precautions provided...

Страница 4: ...ess code This code allows the operation of multiple systems in the same general vicinity The receiver only accepts commands from the transmitter with the same address code MFS Transmission Technology...

Страница 5: ...pment PRACTICES AND LAWS Practice usual and customary safe working precautions for the benefit of yourself and others Understand and follow all safety messages Be alert to unsafe conditions and the po...

Страница 6: ...e gases or liquids Receiver must be protected from ambient temperatures outside the range of 18 to 158 F 25 to 75 C Receiver Production Number Locate the Hetronic Production number decal on the receiv...

Страница 7: ...g 4 Insert the mounting screws through the holes in the housing block and tighten into the mounting surface 5 Bundle any excess antenna cable and secure with tie wraps or equivalent IMPORTANT DO NOT r...

Страница 8: ...system using the new H Link wireless technology These are preset at the factory and are password protected Refer to the HH MFSHL H Link Programming Manual for more details IMPORTANT The Address and F...

Страница 9: ...P DK9 S0 S t o p S t o p DK1 DK2 DK3 DK4 DK5 DK6 DK7 DK8 DK9 DK10 DK11 DK12 DK13 DK14 S1 S2 S3 S4 S5 S6 S7 HH L MFSHL TS7P S t o p S t o p S0 TEST PROCEDURES WARNING FAILURE TO FOLLOW INSTRUCTIONS cou...

Страница 10: ...cates that the E Stop contact is open crane machine motions will NOT operate The LED on the receiver should flash yellow 5 Activate the motion toggle switches There should be NO movement of the crane...

Страница 11: ...that the transmitter batteries are fully charged and inserted into the transmitter handle If any control is NOT in the Off neutral position when the battery is inserted the transmitter will not turn...

Страница 12: ...a switch is active when the batteries are inserted the unit will go into an error state The red LED will come on and stay on until the active switch is turned off LED DESCRIPTION Transmit Mode Green...

Страница 13: ...sposed of with typical refuse Contact a professional hazardous waste disposal service MAINTENANCE WARNING The transmitter will switch to the EMERGENCY STOP condition after the set amount of time expir...

Страница 14: ...fter normal start up procedure E Stop switch engaged Pull out E Stop switch Batteries fully discharged Check batteries to ensure a full charge Replace with new batteries if necessary No power to the r...

Страница 15: ...AA batteries Operation time Up to 500 hours Functions E Stop pushbutton 6 motion toggle switches Proportional grey code trigger switch Antenna Internal HH L MFSHL TS7P TRANSMITTER Weight 1 3 lbs 590g...

Страница 16: ...operator is responsible for understanding and following all safety precautions in this and other applicable operator manuals INSTALLATION AND SAFETY TEST DATA Crane machine Data Manufacturer Model Num...

Страница 17: ...the crane machine controls Maintained control The function activates when the control is placed in the ON position The function stops when the control is placed in the OFF position Momentary control T...

Страница 18: ...c Millisecond MHz Megahertz MOV Metal Oxide Varistor type of surge suppressor mW Milliwatt NiCd Nickel Cadmium NiMH Nickel Metal Hydride PLC Programmable logic controller PLL Phased locked loop PTO Pr...

Страница 19: ...any Company supplied items or materials List prices or discounts are subject to change without notice Quoted prices will be honored for a period of 90 days from the date of the written quotation unles...

Отзывы: