7.2 Charging Unit   

The charger docking station base can be dismantled from the bench-top state to obtain a wall-mount charger instead. 
 
 
    

 

 

 

 

Figure 14. Bench-top or wall-mount variations 

7.2.1 Removing the grippers 

In order to obtain the wall-mount version and mount it to a wall/panel, the grippers must be removed by following the below steps: 

1. The gripper is to be pressed firmly downwards (towards the charger) until the gap is minimized as much as possible. 

 

Figure 15. Pressing the gripper downwards 

2. The gripper clip is to be pressed firmly inwards. 

 

Figure 16. Pressing the clip inwards 

3. The gripper is to be pulled upwards whilst keeping the clip pressed inwards. 

Содержание ERGO-S

Страница 1: ...USER S MANUAL ERGO S USER S OPERATION MANUAL 10 2019 www hetronic com...

Страница 2: ...ter Initialization with Graphic User Interface TFT and Standard Status LED Indicator 9 4 6 Turning OFF the Transmitter and Stopping the Radio Remote Control 9 4 7 LED Behaviour and Meanings 10 4 8 Bat...

Страница 3: ...Access Code 14 Figure 11 Information provided in the About screen 15 Figure 12 Inserting the Battery 17 Figure 13 Charging the ERGO S Battery 17 Figure 14 Bench top or wall mount variations 18 Figure...

Страница 4: ...es against a possible damage to the system in case of non observance of the working instructions TIP This symbol points to features and information which allow for an easier handling or operation 1 3...

Страница 5: ...ter by preventing it from being subject to knocks and scratches This helps to keep the unit s appearance longer and may also protect it from some internal damage should you accidentally knock or drop...

Страница 6: ...ontrol functions and operation of the machine and this radio remote control system When not in use turn the transmitter off and store in a safe place to prevent unauthorized use Ensure that the USB Do...

Страница 7: ...tch Minimum 100 m 300 ft range using CS4XX and CS8xx modules Minimum 60 m 196 ft range using CS2400 RF module Typically 100 m 300 ft range using on board MFS 2G4 radio Internal Antenna Auto power off...

Страница 8: ...ositioning when the TFT is also present on the transmitter Figure 3 Status and Feedback LEDs Feature Description 1 8 Up to 2 Detent Momentary Pushbutton S2 S9 9 11 Single Detent Momentary Pushbutton S...

Страница 9: ...al Operation Mode The Green LED 18 will blink at the baud rate i e the LED toggles on with every transmitted telegram frame All other LEDs switch off Test all machine functions Refer to your machine t...

Страница 10: ...warranty 4 7 LED Behaviour and Meanings The following table gives the meanings for the different behaviours of the Status LED 18 Result Meaning Red Green LED turns ON always Service Mode Green LED Bl...

Страница 11: ...e following standard cable options are available to choose from depending on the application However customized variants can also be ordered a 10m CAN cable without termination jumper 1051512510 b 10m...

Страница 12: ...s in Service Mode The four topmost buttons on the front panel are used to navigate through Service Mode and also to change setting parameters within the menus The menu selection changes with every scr...

Страница 13: ...the baud rate of a unit is changed the baud rate of the paired unit must be changed accordingly Note The coder still supports all other baud rates in cases when non standard radio modules are used 5 2...

Страница 14: ...2 Press button 1 to go to Brightness page 3 Press button 1 to increase brightness or button 2 to decrease brightness 4 Press button 3 to save the new setting and return to the General Settings menu O...

Страница 15: ...ch Italian or German 1 Press button 3 to enter General Settings menu 2 Press button 4 to go to next page of General Settings menu 3 Press button 3 to scroll through the list of available languages 4 P...

Страница 16: ...P function When the transmitter is turned on it performs a self test to confirm that communications are within designated parameters If an error is detected the transmitter will not transmit any signa...

Страница 17: ...are The user can choose to remove the battery from the transmitter and place it directly in the charging unit Else the user can opt to charge the battery by placing the whole transmitter unit in the c...

Страница 18: ...o obtain the wall mount version and mount it to a wall panel the grippers must be removed by following the below steps 1 The gripper is to be pressed firmly downwards towards the charger until the gap...

Страница 19: ...NTAL POLLUTION Recycle your rechargeable batteries according to local recycling rules and regulations If you have questions or problems operating your battery charger please contact your nearest Hetro...

Страница 20: ...stic LEDs in the receiver to be sure power is applied Ensure that the system is properly grounded Transmitter receiver frequency channels do not match Follow instructions under Setting Frequency and c...

Страница 21: ...Range 40 C 85 C 40 F 185 F Humidity Range 95 IEC 60068 2 78 Response Time Less than 100 msec Standard Features Fully programmable via Hetronic PC Link USB Type A Interface with 4Gb Memory key for conf...

Страница 22: ...zed modifications Faults resulting from incorrect installation and use Maintenance and Preventive Care Repairs and maintenance must be carried out by qualified personnel Only use original Hetronic spa...

Страница 23: ...hetronic com 11 2 North America FCC ID LW9 ERGOS2G4 FCC Recommendations This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not c...

Страница 24: ...se undesired operation of the device www hetronic com 2018 Hetronic All rights reserved No part of this publication may be reproduced transmitted transcribed stored in a retrieval system or translated...

Страница 25: ...mming distance A measurement of data transmission safety The amount of failures in the data stream which has to occur during the transmission in order to create a wrong signal A low hamming distance m...

Страница 26: ...ot allow any unauthorized person to operate the transmitter at any point 6 Do not operate the transmitter at a distance where the equipment and all surrounding objects are not visible Make sure that y...

Страница 27: ...tep 2 With JS 3 Full Duplex 3 With SS The table on the following page shows how the item number of an Ergo S unit is broken down and explains what each digit refers to with regards to different featur...

Страница 28: ...S 2G4 V2 W TFT 180mA 71691121 A ERGO S MFS 2G4 V2 W TFT JS 200mA 71691122 A ERGO S MFS 2G4 V2 W TFT SS 215mA 71692010 A 434 ERGO S V1 W O TFT 130mA 71692020 A 434 ERGO S V2 W O TFT 130mA 71692110 A 43...

Страница 29: ...her with their part number which by time may need to be replaced due to wear and tear Item Part number Notes USB Seal Cover 11625100 Yellow Ergo S Holster 11404570 Battery Li Ion 3 7V 3 4Ah 68303700 C...

Отзывы: