background image

1

www.heta.dk

SCAN-LINE

95/

100

OPER

ATING INSTRUC

TIONS

UK

www.heta.dk

Содержание SCAN-LINE100

Страница 1: ...1 www heta dk SCAN LINE95 100 OPERATING INSTRUCTIONS UK www heta dk...

Страница 2: ...mney connection The chimney opening must follow na tional and local regulations However the area of the opening should never of specifications and requirements in tended to ensure that the materials u...

Страница 3: ...ns regarding distance to flammable material must be followed It is important that the chimney is fitted with roof support so that the top panel of the stove is not required to bear the entire weight o...

Страница 4: ...at resistant coating which hardens at a temperature of approximately 250 C This hardening process causes the production of smoke and malodorous fumes so the room must be very well ventilated During th...

Страница 5: ...ou have used 1 kg normal wood Regulating the airflow To adjust combustion airflow use the handle at the front under the door Combustion air flow is fully open when the handle is as far as possible to...

Страница 6: ...combustion and damp wood fuel can cause a he avy sticky coat of soot to form which may cause the door seal to tear off next time the door is opened Risk of explosion After you add new fuel it is very...

Страница 7: ...the weather conditions In high winds the draft can become so powerful that it may be necessary to fit a damper in the flue gas pipe to regulate the draft When cleaning the chimney soot and other depos...

Страница 8: ...fire proof bricks in the combustion chamber The smoke baffle The glass The sealing rope The grate frame Damage resulting from incorrect use Transport costs in connection with repairs carried out under...

Страница 9: ...gure 4 and place the 100 connector on top Turn all 3 locking pins 90 until the connector is secured 6 When the 100 connector is fitted to the damper put the ring with the cord around down at the bot t...

Страница 10: ...ark screen and vacuum any ash in the bottom 2 Baffle Lift and turn the baffle slightly to one side and carefully remove 3 Side stones Turn carefully away from the side of the combustion chamber 4 Rear...

Страница 11: ...THOUT PEDESTAL Special conditions regarding Scan Line 95 100 without pedestal Make sure that the distance from the lower edge of the door to the floor is mini mum 350 mm for Sl95 And 460 for Sl100 Ple...

Страница 12: ...12 14 03 2013 0037 1366 TRANSPORTATION SAFETY DEVISE Regarding Scan Line 100 on a turnable pedestal The screw must be removed before the stove is used turned...

Отзывы: