Declaration of Performance EN

__________________________________________________________________________________________________________________________________

Regulation No. 305/2011

DOP-Scan-Line 500 serien-2354-2018-EN

1. Unique identification code of product-type

Stove

2. Product name

Scan-Line 500, 510, 520, 520B, 550, 551, 560S, 560B, 590, 
Turin Classic, Turin Modern, Napoli, 10-20-30,Tour 10-20-30, 
40-50

3. Intended use or uses of the construction product, in 
    accordance with the applicable technical specification

Room heater burning solid fuel without hot water supply

4. Name and contact address of the manufacturer

Heta A/S, Jupitervej 22, DK-7620 Lemvig. heta

@

heta.dk

5. Where applicable, name and contact address of 
    authorized representative. E-mail.

Martin Bach, E-mail: martin.bach

@

heta.dk

6. System of assessment and verification of constancy of 
    performance of the construction product

System 3

7. Notified body relevant to the assessment and
    verification of constancy of performance

Teknologisk Institut, DK-8000 Aarhus
Notified body No. 1235
Rapport nr. 300-ELAB-2354-EN

  

8. Declared Performance

Harmonized technical specification

EN 13240:2001/A2:2004

Emission

CO                                0,0394% / 493 mg/Nm

3

Nox                               90 mg/Nm

3

Dust                              22 mg/Nm

3

Dust (NS3058/3059)    
OGC (CEN/TS 15883)  51 mgC/Nm

3

 - 13% O

2

  

  Fire safety

Reaction to fire

A1

Test of fire safety in connection with the burning of wood

Approved

Distance to combustible materials
Rear
Sides distance to combustible materials
Furniture distance

Minimum distances in mm
150
350
1000

  

  Safety

Mechanical resistance (to carry a chimney / flue)

Not tested (NPD)

Electrical safety

NA

Surface temperature

Approved

Cleanability

No specification

  Thermal output

Nominal heat output

6,1 kW

Room heat output

6,1 kW

Energy efficiency

Ƞ

 83%

Fluegas temperature at nominal heat output

T 246

o

C

Water heating output

NA

Maximum water operating pressure

NA

  9.

The performance of the product identified in points1 and 2 is in conformity with the declared performance in point 8. This
declaration of performance is issued under the sole responsibility of the manufacturer.

   Signed on behalf the manufacturer of   04.12.2018

____________________________________________________________________________________________________________________

In case of any change of the above-mentioned production type this Declaration of Performance becomes invalid.

Heta A/S, Jupitervej 22, DK-7620 Lemvig, Tlf. +45 9663 0600, www.heta.dk

Page 1 of 1

Certifikat nr. 2354

Содержание Scan-line 500 Series

Страница 1: ...1 OPERATING AND INSTALLATION INSTRUCTIONS DANISH DESIGN DANISH QUALITY DANISH PRODUCTION www heta dk EN ECODESIGN READY SCAN LINE NAPOLI CLASSIC SCAN LINE NAPOLI MODERN...

Страница 2: ...ecification EN 13240 2001 A2 2004 Emission CO 0 0394 493 mg Nm3 Nox 90 mg Nm3 Dust 22 mg Nm3 Dust NS3058 3059 OGC CEN TS 15883 51 mgC Nm3 13 O2 Fire safety Reaction to fire A1 Test of fire safety in c...

Страница 3: ...Heta is a registered trademark of Heta A S 25 11 2020 0037 1224 Version 1 4 Printed in Denmark Subject to printing errors and changes Operating Instructions Contents Declaration of Performance 2 Befo...

Страница 4: ...a good logistics network which transports Heta products with great care for our dealers Neverthe less when in transport or handling damage of the often heavy stoves can occur It is important that upon...

Страница 5: ...s hot after about 3 5 minutes closed door and regulate the air into operating position We re commend all of the first fuel is burned with the combustion air fully open in the operating po sition This...

Страница 6: ...the operating air during firing Be aware that the stove will naturally soot if the operating air is too low This is not good for the environment There is also a risk for the glass the chimney and oth...

Страница 7: ...mney for the surroundings for ex the ridge and trees may cause turbulence Good draft occurs when The difference in temperature in the chimney warmer and outside temperature colder It is clear weather...

Страница 8: ...the use of a NACS natio nal association of chimney sweeps registered chimney sweep In the event of smoke or malodorous fumes are being produced you must first check to see whether the chimney is block...

Страница 9: ...chamber is visible Too rapid combustion Too much chimney draft To test you can open the cleaning hatch but remember to close it again Measure the chimney draft and install a damper in the flue pipe i...

Страница 10: ...re Autum Daily 1 week 30 days 60 90 days 1st Year 2st Year Cleaning the chimney see Chimney C Cleaning the chimney and stove C C Cleaning the stoves firebox C VI C Cleaning combustion air intake C C C...

Страница 11: ...aning after sweeping or before replacing vermiculite stones Note it may be necessary to clean vaccum the holes and air ducts behind the rear stone Order of removing Fire bricks 2 1 3 4 The stove is pr...

Страница 12: ...to a strict quality control during production and before delivery to the dealer Therefore the stoves guarantee is FOR FIVE YEARS Against defects in manufacturing The guarantee does not cover Wearing...

Страница 13: ...andards Installation Instructions Contents 2 Installation instructions 14 2 1 Distance requirements 14 2 2 Floor 14 2 3 Chimney connection 14 2 4 Combustion air and ventilation 15 2 5 Stovedrawings me...

Страница 14: ...front of the fireplace insert the substrate must consist of non combustible material for ex Steel glass plate stone or tile floor The size of the non combustible surface must follow the applicable na...

Страница 15: ...his respect the following requirements must be met Only approved materials may be used from the ventilation unit to the air inlet vent The air inlet vent must be fitted correctly and insulated to prev...

Страница 16: ...the back outlet Fig 4 Remove the bolts holding the top flue outlet Fig 5 Lift the top flue outlet off the stove Fig 6 Insert the flue outlet through the back panel and place against the combu stion ch...

Страница 17: ...ix steel springs E A ceramic top panel F Six ceramic sides G A base panel for the ash door H A radius panel for the ash door 2 7 Clearances for installation EN 13 240 Stove Minimum dimensions Distance...

Страница 18: ...1 If the stove is connected using the top flue pipe metal grate B must be installed before the flue pipe is connected 1 1 1 1 1 2 1 1 2 Before the ceramic cladding is affixed the side base plates C mu...

Страница 19: ...nd loosen the hex screws on the holding brackets Insert the radius panel H from above between the holding brackets and re tighten them 1 2 6 Place the top panel E on the stove If the flue pipe is conn...

Страница 20: ...n 15 of the Deregulation Act 2015 Similarly in Scotland appliances are exempted by publication on a list by Scottish Ministers under section 50 of the Re gulatory Reform Scotland Act 2014 In Wales and...

Отзывы: