1.20 Parts - Scan-Line Napoli - Inside fire chamber
1.18 Stove data table in accordance with en 13240 testing
Tested as a freestanding oven and with uninsulated flue
Stove type
Scan-Line
Nominal
fluegas
temperature,
at 20°C
room tem-
perature
Flue
mm
Fuel
volume
kg
Draft
min.
mbar
Nominal
output
tested
kW
Actual
efficiency
%
Distance to flamable materials Stove
weight
kg
at the
sides
mm
rear the
stove
mm
to
furnitures
mm
Napoli
246
C°
ø150
1,2
0,11
6,1
83
350
150
1000
114-250
The nominal output is the output to which the stove has been tested.
Testing is conducted with the combustion air around 38% open.
1.19 Guarantee
Heta wood stoves, subjected to a strict quality
control during production and before delivery to
the dealer.
Therefore, the stoves guarantee is
FOR FIVE YEARS
Against defects in manufacturing
The guarantee does not cover:
Wearing parts / fragile parts such as:
- Vermiculite stones in the combustion
chamber, glass, seals and the casted bottom
or shaking grate.
- Damage caused by improper use.
- Transportation costs for warranty repair.
- Assembly / disassembly of warranty repair.
Should you have cause to make a complaint,
please quote our invoice no.
Warning
Any unauthorized alterations to the
stove and the use of non-original
parts will void the warranty.
Pos. No.
Name
Qty
1 0023-0075 Upper baffle
1
2 0023-0076 Right side stone
1
3 0023-0077 Left side stone
1
4 0023-0078 Back stone
1
5 1500-022221 Log retainer
1
6 0015-2013 Knob
1
7 1021-4062 Shake pin
1
8 0030-0201 Grate
1
9 0030-0013 Casted bottom
1