Owner’s Guide
Installation & Operation
Fryer
HFR Series
Hestan Commercial Corporation
3375 E. La Palma Ave
Anaheim, CA 92806
(888) 905-7463
RETAIN THIS MANUAL FOR FUTURE REFERENCE
P/N 002137 REV 1
Страница 1: ...Owner s Guide Installation Operation Fryer HFR Series Hestan Commercial Corporation 3375 E La Palma Ave Anaheim CA 92806 888 905 7463 RETAIN THIS MANUAL FOR FUTURE REFERENCE P N 002137 REV 1...
Страница 2: ...NTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPE...
Страница 3: ...lation 5 Statutory Regulations 5 United States of America 5 Canada 5 Appliances Equipped with Casters 6 Gas Supply 7 Gas Pressure Regulator 8 Ventilation Air Flue Connections 9 Model Serial Rating Pla...
Страница 4: ...be kept free and clear of combustible materials Clearances The following minimum clearances must be followed COMBUSTIBLE NON COMBUSTIBLE Model BACK SIDE BACK SIDE Fryer 6 6 0 0 NOTE For use on combus...
Страница 5: ...allation of this appliance must be carried out by a properly trained and qualified installer and in accordance with the relevant regulations codes of practice and the related publications of the Count...
Страница 6: ...ANSI Z21 69 CSA 6 16 or latest edition and a quick disconnect device that complies with Standard for Quick Disconnect of Use with Gas Fuel ANZI Z21 41 CSA 6 9 or latest edition 2 Adequate means must...
Страница 7: ...is fitted or the automatic system can be reset this notice must be posted ALL DOWNSTREAM BURNER AND PILOT VALVES MUST BE TURNED OFF PRIOR TO ATTEMPTING TO RESTORE THE SUPPLY AFTER EXTENDED SHUT OFF P...
Страница 8: ...water solution Do not use an open flame After piping has been checked for leaks all piping receiving gas should be fully purged to remove air Ventilation Air Flue Connections The following notes are i...
Страница 9: ...2015 Hestan Commercial Corporation 9 Model Serial Rating Plate Locations Fryers Rating plate will be located above the front panel...
Страница 10: ...lit Release the dial the pilot should remain lit Repeat as needed until the pilot remains lit 3 To light the burners turn the gas valve dial to the ON position and turn thermostat to the desired tempe...
Страница 11: ...en the material then use a wood or nylon scraper All water must be removed before adding oil or shortening Not doing so can result in splattering of hot oil causing severe burns and burn hazard DO NOT...
Страница 12: ...fts Low gas pressure to unit Faulty pilot generator on gas valve Thermostat is set to very low temperature Check temperature setting and adjust to proper or desired values Fryer does not reach selecte...