Mobile Evaporative Cooler

 

Use & Care Guide

 

MC26A

 

2100 CFM

 

General Safety Precautions

 

Unit must be in 

OFF

 position and 

UNPLUGGED

 from   

power receptacle before performing any maintenance /  

service or before 

REMOVING

 access panels.

 

Make sure the electrical power source conforms to the re-

quirement of the evaporative cooler as well as local codes.

 

To reduce risk of fire or electrical shock, do not expose 

electrical connections to water.

 

Do not touch electrically live components.

 

Ensure all power cords do not touch sharp edges, hot sur-

faces or chemicals.  Immediately replace damaged parts.

 

Never leave unit unattended.

 

Continuous fill not to be used indoors or unattended.

 

Read and follow all instructions, cautions        

and warnings.  Failure to do so could result  

in personal injury, death or property damage. 

Operation Tips

 

Hessaire coolers are highly recommended for outdoor use. 

If used indoors, position cooler in front of window or open 

door for fresh intake air.  Ensure there is an open door or 

window through which the air can exhaust from the room.

 

Clean media pads and tank frequently.

 

When shutting down unit, run without pump for 30 minutes 

to properly dry media pads.  

 

Prior to long term storage:

 

Drain tank and wipe clean

 

Dry and clean rigid media pads

 

 

1

 

Indoor Use:          

Do Not Use Garden 
Hose Attachment.

 

Содержание 2100 CFM

Страница 1: ...sure all power cords do not touch sharp edges hot sur faces or chemicals Immediately replace damaged parts Never leave unit unattended Continuous fill not to be used indoors or unattended Read and fol...

Страница 2: ...Cooler 5 Turn On Enjoy 2 Install Hose Adapter Not For Indoor Use Features Remote Control Functions Pump Timer Power Swing 3 Fan Speed Control Panel For MC26A With Humidity Control Swing Button Press t...

Страница 3: ...emedy Cooler won t turn on Ensure unit is plugged in and switched on Receptacle breaker may need to be reset If unit is equipped with a GFCI plug reset If unit has a timer ensure it is off May need ne...

Страница 4: ...sibility of the purchaser Hessaire does not cover labor costs associated with troubleshooting or cooler repairs regardless if the product is under warranty or not Damaged Shipments Hessaire is not res...

Страница 5: ...ordes afilados superficies calientes o productos qu micos Reemplace inmediatamente las piezas da adas Nunca deje la unidad desatendida Lea y siga todas las instrucciones precauciones y adverten cias E...

Страница 6: ...so en interiors Caracteristicas Funciones Bomba Temporizador Encendido Apagado Oscillaci n 3 Velocidad Bot n de oscilaci n presione para operar la funci n de oscilaci n Bot n del temporizador se encie...

Страница 7: ...eg rese de que la unidad est enchufada y encendida Es posible que sea necesario restablecer el disyuntor del recept culo Si la unidad est equipada con un enchufe GFCI rein cielo Si la unidad tiene un...

Страница 8: ...n la resolu ci n de problemas o las reparaciones de enfriadores independiente mente de si el producto est en garant a o no Env os da ados Hessaire no se hace responsable de los env os da ados o la esc...

Отзывы: