![HESCH HE 5712 Compact Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/hesch/he-5712-compact/he-5712-compact_operating-instructions-manual_2127268026.webp)
26
HE 5712 Operating Instructions
# 372048 | Version 1.4
6.3
Offset for Zeroing
1.
Press PARA key.
2.
Use the UP / DOWN keys to select the "Zeroing" parameter.
3.
Confirm with the ENTER key. The display flashes.
4.
Press UP / DOWN simultaneously for 2 seconds. The currently
measured value is inverted and accepted as the offset.
5.
If the UP / DOWN keys are pressed independently, the offset value
can be set manually.
6.4
Parameterisation with Service PC
When parameterising several devices, parameterisation with a service PC is recommended.
The USB / TTL adapter required for this is available from HESCH. The parameters can be
changed via PC and the "EasyTool Controls" program. The program can be used to save a
configuration or to restore a saved configuration.
1.
Connect the PC to the operating unit via USB cable.
2.
Start "EasyTool Controls" to transfer the files or data.
Note!
Instructions for the most important program functions are available from
HESCH.
6.5
Enable / Disable Precoating
Enable:
Press the TEST key and the UP key simultaneously.
PrE" is displayed alternately with other information.
Disable:
Press the TEST key and the DOWN key simultaneously.
After reaching the first cleaning threshold (increased by the precoating), the precoating is
automatically disabled.