-
43
-
4.1
Home
NOTE This screenshot may not display the most current version
numbers. See Section 4.7 (Upgrade).
Spin Rate of the motor (revs per minute) = frame rate (Hz) * 60
GPS (PPS) Status
Lock
LiDAR's internal clock is in sync with GPS
Unlock
Not in sync
NMEA (GPRMC/GPGGA) Status
Lock
After receiving a valid NMEA message
Unlock
Not receiving a valid NMEA message
PTP Status
Free Run
No PTP master selected
Tracking
Slave is trying to sync with the selected PTP Master,
but the absolute offset is over 1 μs
Locked
Absolute offset between Slave and Master is < 1 μs
Frozen
(Holdover)
LiDAR has lost connection to the PTP master and is
attempting to recover it.
Meanwhile, LiDAR starts drifting from the previous
clock; when drifting out of specifications, it goes
back to the Free Run mode.
Device Log
Click to download a .JSON file containing the LiDAR's status, device
info, all configurable parameters, and upgrade log.
Содержание Pandar128E3X
Страница 1: ...www hesaitech com HESAI Wechat Pandar128E3X 128 Channel Mechanical LiDAR User Manual...
Страница 11: ...9 2 Setup 2 1 Mechanical Installation Figure 2 1 Front View Unit mm...
Страница 12: ...10 Figure 2 2 Bottom View Unit mm...
Страница 13: ...11 Quick Installation Figure 2 3 Quick Installation...
Страница 14: ...12 Stable Installation Figure 2 4 Stable Installation...
Страница 57: ...55 4 6 Monitor The LiDAR s input current voltage and power consumption are displayed...
Страница 60: ...58 4 9 Security Cyber Security Master Switch OFF Cyber Security Master Switch ON...
Страница 70: ...68 In case the following warnings appear select Trust this CA to identify websites...