TW-820T
9
5.Attachment of TW-820T
<Attachment to wrenches>
①
Attachment of the harness connector with limit switch
The harness connector is attached to the transmitter at factory. When it is removed for maintenance or
replacement, securely connect the harness connector with limit switch so that the black cable sits on the outer
side, as shown below.
The connector cannot be inserted in the wrong orientation.
②
Attachment of the limit switch to the wrench base
Fix the limit switch to the wrench base by using the two supplied limit switch fixing bolts and flat washers.
When operating the wrench, make sure the movable range of the wrench lever matches the working range of
the limit switch.
◆
The attention and the check method on limit switch attachment
When the wrench lever working range of a wrench is small, a limit switch cannot be struck and a transmitter
may not send. In limit switch attachment, be careful enough and carry out.
It is recommended to check the attached condition of the limit switch by using a tester.
Wrench lever
The hex socket head cap bolt requires a washer.
Apply screw lock agent to the bottom 2 to 3 threads of the
hex socket head cap.
Wrench base
Limit switch