background image

G-100ES

Duct Mount Humidifier

Installation • Operation • Maintenance 

CAUTION:
READ INSTALLATION, OPERATION, AND MAINTENANCE
INSTRUCTIONS CAREFULLY FOR SAFE OPERATION. 
EXERCISE EXTREME CAUTION WHEN WORKING WITH
ELECTRICITY.

252907-001 9/04

Содержание G-100ES

Страница 1: ...unt Humidifier Installation Operation Maintenance CAUTION READ INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS CAREFULLY FOR SAFE OPERATION EXERCISE EXTREME CAUTION WHEN WORKING WITH ELECTRICITY 2...

Страница 2: ...ntents Introduction 1 Specifications 2 Capacity Selection Guide 3 Operation 3 Installation 5 Mounting Locations 6 Maintenance 7 Troubleshooting 9 Description of Parts 11 Parts List 12 Unit Diagram 13...

Страница 3: ...at 71 to 72 F without controlled humidity Since every degree of temperature setback represents about 3 of your heating costs this can possibly represent a significant annual savings During the heatin...

Страница 4: ...mer shut down Be sure to install a new evaporator pad at the beginning of the heating season before starting the humidifier Like your heating system and air conditioning unit periodic maintenance and...

Страница 5: ...to control the flow of water by using the saddle valve It is designed to be either fully open or closed A felt pad located in the distribution tray distributes water evenly between the openings The d...

Страница 6: ...for the desired conditions 30 40 Relative Humidity is typically recommended but it is important to reduce the setting whenever extreme low outdoor temperatures occur in order to avoid excessive conden...

Страница 7: ...s using the auxiliary terminals interlocked to the furnace fan connect the primary of the supplied 120VAC 220 240VAC International to 24VAC transformer to the auxiliary terminals on the furnace Connec...

Страница 8: ...on the return duct It is recommended that when the unit is installed in this location it is supplied with hot water service 2 If the furnace has an air conditioning coil be sure the unit does not inte...

Страница 9: ...d be installed upstream of the conical mesh filter to reduce the frequency of cleaning Water softeners can be used to improve the quality of the supply water however deionized water is corrosive and c...

Страница 10: ...l not to disturb the drain connection Remove the old evaporator pad and discard 5 Inspect the interior of the humidifier and remove any mineral deposits and accumulation from the frame assembly and dr...

Страница 11: ...ould be an improper electrical installation The humidifier is designed to be used in conjunction with the furnace blower Q Water is constantly flowing out the humidifier drain and I am afraid that it...

Страница 12: ...Corrective Action Replace the evaporator pad Clean or replace conical mesh filter and fluid restrictor Increase the humidity setting on the humidistat Turn the saddle valve handle in a counterclockwi...

Страница 13: ...enoid valve Must be cleaned or replaced when water flow is impeded or humidification is reduced Evaporator Pad Allows water to evaporate as warm dry air is drawn through it Must be replaced on a regul...

Страница 14: ...120VAC 24VAC Transformer 220 240VAC 24VAC Unit cover Water distribution tray Saddle valve assembly Humidistat Capacitor 120VAC Capacitor 220 240VAC 454275 002 251461 001 G 125 12 353226 001 G 116 6 G...

Страница 15: ...13 Unit Diagram 1 2 3 4 8 9 10 11 12 13 14 15 16 7 17 5 6...

Страница 16: ...edders com Humidifiers which have been installed or become part of real estate cannot be returned CareCo will receive freight prepaid only removable parts or components of such defective humidifiers 6...

Отзывы: