Herholdt Controls ECS1-125 Скачать руководство пользователя страница 1

Running tarif, called tarif

Displays capacitative, reactive
power

kWh / kvarh display

Displays inductive, reactive
power

1000 imp/kWh

Precision control LED

Consumption Bar display
(percentage of

Pmax

)

Full scale current indication

-

1

/ 12 -

“ECS1-125”

Herholdt Controls srl

- 20132 Milano (Italy)

A)

Device code and certification data indications

B)

Safety-sealing between upper and
lower housing part

B

Me

nu

SET

St

art

EC

SE

M1

17

MI

D

EC

S1

-12

5 M

M-B

us

10

00

Im

p/k

Wh

kWh

Cl

.B

(C

l.1

)

23

0V

50

Hz

0.2

5-5

(12

5)A

-25

°C

to

55

°C

A

A

kva

rh

MID calibrated

282351 - ECSEM107MID

ECSEM117MID

WARNING

Installation must be carried out and inspected by a specialist or under his supervision.

When working on the instrument, switch off the mains voltage!

Single-phase Digital Energy meters - Direct connection 125 A

ECS1-125

Installation and Operating Instructions

active and reactive energy-meter with measurement of active and reactive instantaneous power - 2 tariff - 2 S0

Code

Model

Description

ECSEM127

ECS1-125

single-phase digital active and reactive energy-meter with active and reactice power indication
direct connection 0.25-5 (125) A -

2 tariffs

-

2 S0

282351

ECS1-125 MID

d.to with

MID

certified

active and reactive energy-meter with measurement of active and reactive instantaneous power, and inbuilt communication M-Bus - 2 tariff

Code

Model

Description

ECSEM124

ECS1-125 M-Bus

single-phase digital active and reactive energy-meter with active and reactice power indication
direct connection 0.25-5 (125) A -

2 tariffs

-

2 S0

- and inbuilt communication

M-Bus

ECSEM117MID ECS1-125 MID M-Bus

d.to with

MID

certified

active and reactive energy-meter with measurement of active and reactive instantaneous power, and inbuilt communication Modbus RTU - 2 tariff

Code

Model

Description

ECSEM106

ECS1-125 Modbus

single-phase digital active and reactive energy-meter with active and reactice power indication
direct connection 0.25-5 (125) A -

2 tariffs

-

2 S0

- and inbuilt communication

Modbus RTU

ECSEM107MID ECS1-125 MID Modbus

d.to with

MID

certified

• This family of devices provides a set of single phase energy meters designed to be directly connected to system where high current is required. All the meters are equipped with an easy

to read LCD with green back light on which displays all the active and reactive energy counters, with a red light LED which blink in proportion to the measured active energy and with a
optocoupler that allows the storage of energy on two different tariffs. Depending on the model a insulated M-Bus communication interface or a insulated Modbus communication
interface are built in two solid state relay which generate pulses proportional to the measured energy. Both M-Bus and Modbus communication interfaces offers a set of 15 measures.

Dimension

64

45

6

90

44

L1

N

L1

1 2 3 4

6

5

54

Sealable terminal covers

125 A direct connection main terminals - Screw driver PZ2

Cable stripping length and max. terminal screw torque

15.5

2 Nm

Tariff and communication terminals
Screw driver blade 0.8x3.5 mm

9

0.8 Nm

Display

Energy value

Energy export (absorbed

)

Energy import (supplied

)

Menu key for reading

selection

Parameters set

Commands

IIST062-02

Stand 30-05-2013

Symbols

Measuring elements

Reversal preventing device

Protected by double insulation

Содержание ECS1-125

Страница 1: ...n M Bus ECSEM117MID ECS1 125 MID M Bus d to with MID certified active and reactive energy meter with measurement of active and reactive instantaneous power and inbuilt communication Modbus RTU 2 tarif...

Страница 2: ...equipped with M Bus In these pages the Secondary address appears These address can range from 1 to 99999999 hence requires 2 pages the 1st for the 4 highest digit the 2nd for 4 lowest digit In this e...

Страница 3: ...st Main Menu Main Menu 4 sec 4 sec 3 12 ECS1 125 Communication Address Modbus In the Address page by kept pushed for 4 sec the Start key the value of the Address blink on the display Push Start key or...

Страница 4: ...menu of the energy counters The zeroing menu is available only in the meter not MID certified When the display shows rESET the key must be released To do the reset press it again afterwards it will g...

Страница 5: ...nection A 0 020 125 0 020 125 Operating frequency Hz 48 62 48 62 Certified frequency Hz 50 50 Starting current for energy measurement Ist mA 20 20 Pulse output S0 acc to EN 62053 31 Pulse output for a...

Страница 6: ...6 12 ECS1 125 Herholdt Controls srl 20132 Milano Italy Note...

Страница 7: ...Tarife Kode Typ Beschreibung ECSEM124 ECS1 125 M Bus Wirk Blindenergiez hler mit Wirk Blindleistungsanzeige f r Direktanschlu 0 25 5 125 A 2 Tarife und eingebauter Kommunikation M Bus ECSEM117MID ECS1...

Страница 8: ...ngebauter M Bus Schnittstelle In diesen 2 Seiten wird die sekund re Adresse eingegeben Die Adressierung besteht aus einer Zahl zwischen 1 und 99999999 und kann daher auf 2 Seiten geschrieben werden Au...

Страница 9: ...Start Taste blinkt der einzustellende Wert Nach erreichten Baudrate uber die Tasten gleich mit der Haupttaste Men den Einstellwert best tigen ansonsten wird der Vorgang nach 5 Sekunden gel scht S0 Im...

Страница 10: ...ung Das Ger t ben tigt keinerlei Eichung w hrend seiner Lebenszeit Alle Bauteile haben keinen mechanischen Verschlei Die Sensorik f r Strom und Spannung mit sachgem en Gebrauch haben keine Abweichunge...

Страница 11: ...sungsfrequenz fn beglaubigt Hz 50 50 Frequenz Hz 48 62 48 62 Eingangswelligkeitsform AC AC Betriebsanlaufstrom Ist mA 20 20 S0 Schnittstelle nach EN 62053 31 Impulsausg nge nur f r Wirk u Blindenergie...

Страница 12: ...12 12 ECS1 125 Herholdt Controls srl 20132 Milano Italy Notizen...

Отзывы: