background image

Operation Manual                                                                                                                                                                                                                                         
 

BinTrac Breeder Control Operation Manual

 

Ver. 1.01 Rev 1.04

 

Part # MAN-000008

 

200. 

100. 

50. 

….. 

10. 

5. 

2. 

1. 

500. 

Increment Value 

Sets the increment that the bin weight will display at.  The reading from a bin is  
rounded to the nearest multiple of the increment, using standard rounding rules. 
The possible values are: 1, 2, 5, 10, 20, 50, 100, 200, 500, 1., 2.,5.,10.,20.,50..   

    

See figure 2.   
 ** Example: If a

n increment of 10 is selected and the net value of a bin’s weight is  

18,582 lbs.; the segmented display will read 18580.    

Note:

  When the increment number is followed by a 

“.”

 the displayed weight  

value is then scaled by 10.  (120462 is displayed as 12046.)  This is required 
when the displayed weight will exceed five digits.  

 

1.  Press the SELECT key to select the desired bin. 

2.  Use the 

 key to increase the value to the nearest 10 units. 

3.  Use the 

 key to decrease the value to the nearest 10 units. 

 

Segmented display: 

 

 

 

       

Figure 2 

Full Value 

Sets the maximum weight of a full bin either in pounds or kilograms.   It is how much material the bin can hold.   This is 
for calibration of the LED bar graph level.  The value says at what net weight the bar graph will display completely full 
(all 16 LEDs lit).  

 

      

 

 

 

 

 

 

1.  Press the SELECT key to select the desired Bin. 

2.  Use the 

 key to increase the value by 1 unit. 

3.  Use the 

 key to decrease the value by 1 unit. 

 
 

Segmented display: 

 

 

 

 

 

 

 

 

 

 

Zero Value 

Sets the weight of the empty bin either in pounds or kilograms.  This value can also be set in the Operation Settings. 
This is used to compensate for the empty weight of the bin to give an accurate value for the net weight of the material 
inside the bin. ** Example: A bin weighs 1,200 lbs. empty.  This is then set to the zero value: the BinTrac then 
calculates the material weight as the total weight less the zero weight value.   

 

1.  Press the SELECT key to select the desired Bin. 

2.  Use the 

 key to increase the value by 1 unit. 

3.  Use the 

 key to decrease the value by 1 unit. 

 

Segmented display: 

 

 

 
 

fULL 

ZEro 

inc 

Содержание Bintrac

Страница 1: ...Operation Manual 12 1 2012 Breeder Control Operation Manual Patented U S Patent No 7 980 129 and Patents Pending...

Страница 2: ...n Option in Setup mode 5 Options in Setup Mode 6 Setup Version 1 0 and higher 6 Serial Data Command Set 6 Batch 7 Rated 7 Capacity 7 Increment Value 8 Full Value 8 Zero Value 8 Year 9 Month 9 Date 9 H...

Страница 3: ...es the signals from all brackets to minimize errors that could result from voids holes in the material Smart Summing Box A single Smart Summing Box per bin communicates the current reading on the leg...

Страница 4: ...key for approximately 8 10 seconds The bin level gauge will go blank and all of the bin selector indicators will illuminate showing their current status 1 Press the SELECT key to select the desired bi...

Страница 5: ...ce is powered up it will automatically enter SETUP mode and display the Ver 2 This method requires you to hold the SELECT button down for approximately 10 seconds at which time SETUP mode will be disp...

Страница 6: ...roadcast ASCII weight data will be serially broadcast approximately once ever second RUN Enable communications to peripheral devices Must be enabled when BinTrac Monitor is connected to BinTrac Remote...

Страница 7: ...ad cells DO NOT CHANGE unless necessary Every standard load cell has a rated output specified in mV V If using load cells other than the Herdstar load cells adjust this value appropriately 1 Press the...

Страница 8: ...units Segmented display Figure 2 Full Value Sets the maximum weight of a full bin either in pounds or kilograms It is how much material the bin can hold This is for calibration of the LED bar graph le...

Страница 9: ...the current Minute Segmented display Station ID Value Sets the Station ID of the device For devices interfacing with a Site Console the Station ID must be set within 100 131 When interfacing the devic...

Страница 10: ...CT key to see the software version number Segmented display Smart Summing Box Software Version Version 3 0 and higher Displays each of the connected Smart Summing Boxes programmed software version num...

Страница 11: ...h run control status run or Stop 6 Use the or keys to enable or disable batch run control 7 Press SELECT to start Batching if run was selected The batch run will begin immediately Scheduled Batch Run...

Страница 12: ...while a batch is running and the weight increases by 50 lbs or more in the bin the BinTrac WBBS will pause the batch and switch to FILL batching mode until FILL is completed 4 The unit will remain in...

Страница 13: ...oadcell no bin This means that the Smart Summing Box for the selected bin is not communicating Check for broken wires or loose connections or Smart Summing Box is not correctly configured or faulty lo...

Страница 14: ...ranty sets forth Buyer s sole and exclusive remedies for any defect in the goods The rights and obligation under this warranty may not be assigned or delegated to a third party by Buyer without the pr...

Отзывы: