200.
100.
50.
…..
10.
5.
2.
1.
500.
Increment Value
Sets the increment that the bin weight will display at. The reading from a bin is
rounded to the nearest multiple of the increment, using standard rounding rules.
The possible values are: 1, 2, 5, 10, 20, 50, 100, 200, 500, 1., 2.,5.,10.,20.,50..
See figure 2.
** Example: If a
n increment of 10 is selected and the net value of a bin’s weight is
18,582 lbs.; the segmented display will read 18580.
Note:
When the increment number is followed by a
“.”
the displayed weight
value is then scaled by 10. (120462 is displayed as 12046.) This is required
when the displayed weight will exceed five digits.
1. Press the SELECT key to select the desired bin.
2. Use the
key to increase the value to the nearest 10 units.
3. Use the
key to decrease the value to the nearest 10 units.
Segmented display:
Figure 2
Full Value
Sets the maximum weight of a full bin either in pounds or kilograms. It is how much material the bin can hold. This is
for calibration of the LED bar graph level. The value says at what net weight the bar graph will display completely full
(all 16 LEDs lit).
1. Press the SELECT key to select the desired Bin.
2. Use the
key to increase the value by 1 unit.
3. Use the
key to decrease the value by 1 unit.
Segmented display:
Zero Value
Sets the weight of the empty bin either in pounds or kilograms. This value can also be set in the Operation Settings.
This is used to compensate for the empty weight of the bin to give an accurate value for the net weight of the material
inside the bin. ** Example: A bin weighs 1,200 lbs. empty. This is then set to the zero value: the BinTrac then
calculates the material weight as the total weight less the zero weight value.
1. Press the SELECT key to select the desired Bin.
2. Use the
key to increase the value by 1 unit.
3. Use the
key to decrease the value by 1 unit.
Segmented display:
fULL
ZEro
inc