System Setup
The units are easily wired by a qualified technician using standard communication wiring. See Appendix A and
Appendix B drawings for detailed load and unload wiring information. The System setup has two levels of settings: 1)
Operation Settings: These are
settings that may be changed for normal use by an operator and 2) System Settings:
These are a one-time setup usually done at the time of installation.
Operation Settings
New BinTrac Breeder Control installations require a one-time system configuration procedure before use. In this mode
you can configure the batching method you wish to use.
Selecting Batching Method
This procedure will allow you to select the batching method you wish to use. On the BinTrac
Indicator, press and hold the SELECT key for approximately 8-10 seconds. The bin level gauge
will go blank, and all of the bin selector indicators will illuminate showing their current status.
1. Press the SELECT key to select the desired bin.
2. Press the
key
to proceed. The indicator for bin “A” will remain on, and all others will turn off. If the indicator
is on steady, “A” bin is being monitored. If it is flashing, the bin is not being monitored. Press the
or
key to toggle bin monitoring on or off.
3. Repeat steps 2-3 for additional bins.
4. Unit returns to Weight Display mode after this procedure or after 20 seconds of no activity (no keystrokes).
Calibrate Bin Empty (Zero)
This procedure will zero the BinTrac weight by correcting for the dead-load of the empty bin.
1. Press the SELECT key to select desired Bin.
2. Press the
and then the
key and hold for 5 seconds. While held, the bar graph and bin indicators will
flash until 5 seconds have passed and the indicated bin level has been zeroed.
3. Unit returns to Weight Display mode after this procedure or after