Operation Manual                                                                                                                                                                                                                                         
 

BinTrac Breeder Control Operation Manual

 

Ver. 1.01 Rev 1.04

 

Part # MAN-000008

 

 
Thank you for purchasing a BinTrac Breeder Control from Herdstar, LLC.  

Overview 

Your BinTrac Breeder Control provides a cost effective way to automatically monitor bin level and batch a programmed 
load or unload amount.   

Components 

A BinTrac Breeder Control consists of four basic components:

 

 

                                  

BinTrac Breeder Control  

This is the main unit of the BinTrac system. The BinTrac Breeder Control communicates  
with the Smart Summing Boxes to register the weight of material in the bins. The material  
level is computed and displayed on the LED bar graph.   
     

 

 

 

 

 

 

 

 

 

    

Load Cell Bracket 

Four or more loadcell brackets allow the BinTrac to accurately measure the material weight in your bins. The Smart 
Summing Box averages the signals from all brackets to minimize errors that could result from voids (holes) in the 
material.   

 

Smart Summing Box 

A single Smart Summing Box per bin communicates the current reading on the leg brackets to the Bintrac Breeder 
Control. 

 

BinTrac Power Supply 

This provides the power for the BinTrac Breeder Control. The power supply converts the line voltage to low voltage. 
 
 

Features 

 

Weight Display 

The Bintrac Breeder Control displays the gross weight of the bin and its level. 
 

Batch Run 

The Bintrac Breeder Control features a relay to enable a load or unload system for batching a programmed amount. 
 

Fill Events 

The Bintrac Breeder Control records the net weight increase of the last four fill events for each enabled bin. 
 

24hr Usage 

The Bintrac Breeder Control records the last four operational 24 hour usage amounts.  
 

Remote Display 

A Bintrac Breeder Control can be configured as a Remote Display which will display the same updated weight 
information from the host BinTrac Indicator. 
 

Содержание Bintrac

Страница 1: ...Operation Manual 12 1 2012 Breeder Control Operation Manual Patented U S Patent No 7 980 129 and Patents Pending...

Страница 2: ...n Option in Setup mode 5 Options in Setup Mode 6 Setup Version 1 0 and higher 6 Serial Data Command Set 6 Batch 7 Rated 7 Capacity 7 Increment Value 8 Full Value 8 Zero Value 8 Year 9 Month 9 Date 9 H...

Страница 3: ...es the signals from all brackets to minimize errors that could result from voids holes in the material Smart Summing Box A single Smart Summing Box per bin communicates the current reading on the leg...

Страница 4: ...key for approximately 8 10 seconds The bin level gauge will go blank and all of the bin selector indicators will illuminate showing their current status 1 Press the SELECT key to select the desired bi...

Страница 5: ...ce is powered up it will automatically enter SETUP mode and display the Ver 2 This method requires you to hold the SELECT button down for approximately 10 seconds at which time SETUP mode will be disp...

Страница 6: ...roadcast ASCII weight data will be serially broadcast approximately once ever second RUN Enable communications to peripheral devices Must be enabled when BinTrac Monitor is connected to BinTrac Remote...

Страница 7: ...ad cells DO NOT CHANGE unless necessary Every standard load cell has a rated output specified in mV V If using load cells other than the Herdstar load cells adjust this value appropriately 1 Press the...

Страница 8: ...units Segmented display Figure 2 Full Value Sets the maximum weight of a full bin either in pounds or kilograms It is how much material the bin can hold This is for calibration of the LED bar graph le...

Страница 9: ...the current Minute Segmented display Station ID Value Sets the Station ID of the device For devices interfacing with a Site Console the Station ID must be set within 100 131 When interfacing the devic...

Страница 10: ...CT key to see the software version number Segmented display Smart Summing Box Software Version Version 3 0 and higher Displays each of the connected Smart Summing Boxes programmed software version num...

Страница 11: ...h run control status run or Stop 6 Use the or keys to enable or disable batch run control 7 Press SELECT to start Batching if run was selected The batch run will begin immediately Scheduled Batch Run...

Страница 12: ...while a batch is running and the weight increases by 50 lbs or more in the bin the BinTrac WBBS will pause the batch and switch to FILL batching mode until FILL is completed 4 The unit will remain in...

Страница 13: ...oadcell no bin This means that the Smart Summing Box for the selected bin is not communicating Check for broken wires or loose connections or Smart Summing Box is not correctly configured or faulty lo...

Страница 14: ...ranty sets forth Buyer s sole and exclusive remedies for any defect in the goods The rights and obligation under this warranty may not be assigned or delegated to a third party by Buyer without the pr...

Отзывы: