Select Weight Display 

Press the SELECT key to select between Gross weight and Batch amount. The Gross Weight 
is the total material remaining in the bin. The bar graph indicates the approximate level of the 
bin. The Batch amount is remaining weight left to batch to reach the Batch Target. Note: Batch 
Weight always starts at the Batch Target 

and counts down to “0” weight.  This provides the best 

means to display the amount left to batch. 
 

Manual Batch Run 

1.  Press  

  

key until “

bAtch

 is displayed.  

2.  Press SELECT to view the Batch Target Weight value. 

3.  Use the 

 key to increase the value by 1. 

4.  Use the 

 key  to decrease the value by 1 

5.  Press SELECT to display the batch run control 

status ( “

run

”  or “

Stop

” ) 

6.  Use the 

 or  

 keys to enable or disable batch run control.    

7.  Press SELECT to start Batching if run was selected. The batch run will begin immediately.  

Scheduled Batch Run 

1.  Press  

  

key until “

bAtch

 is displayed.  

2.  Use the 

 

key to select “

SchdL

”. 

3.  Use the 

 key to select hour and minute to schedule batch.  

Note: This is a 24 hour clock. ie. 13:00 = 1:00 p.m. 

4.  Press SELECT to view the Batch Target Weight value. 

5.  Use the 

 key to increase the value by 1. 

6.  Use the 

 key  to decrease the value by 1 

7. 

Press SELECT to display the batch run control status ( “

run

”  or “

Stop

” ) 

8.  Use the 

 or  

 keys to enable or disable batch run control.    

9.  Press SELECT 

with “

run

” displayed. The Indicator will then display the batch amount and a countdown to the 

next batch run.  

10.  To stop a scheduled batch run use the 

 

key and “

StOP

” will be displayed. Press the SELECT key once to 

stop and again on the batch amount. The Indicator will then return to display the gross amount in the bin. 

 

 

Содержание Bintrac

Страница 1: ...Operation Manual 12 1 2012 Breeder Control Operation Manual Patented U S Patent No 7 980 129 and Patents Pending...

Страница 2: ...n Option in Setup mode 5 Options in Setup Mode 6 Setup Version 1 0 and higher 6 Serial Data Command Set 6 Batch 7 Rated 7 Capacity 7 Increment Value 8 Full Value 8 Zero Value 8 Year 9 Month 9 Date 9 H...

Страница 3: ...es the signals from all brackets to minimize errors that could result from voids holes in the material Smart Summing Box A single Smart Summing Box per bin communicates the current reading on the leg...

Страница 4: ...key for approximately 8 10 seconds The bin level gauge will go blank and all of the bin selector indicators will illuminate showing their current status 1 Press the SELECT key to select the desired bi...

Страница 5: ...ce is powered up it will automatically enter SETUP mode and display the Ver 2 This method requires you to hold the SELECT button down for approximately 10 seconds at which time SETUP mode will be disp...

Страница 6: ...roadcast ASCII weight data will be serially broadcast approximately once ever second RUN Enable communications to peripheral devices Must be enabled when BinTrac Monitor is connected to BinTrac Remote...

Страница 7: ...ad cells DO NOT CHANGE unless necessary Every standard load cell has a rated output specified in mV V If using load cells other than the Herdstar load cells adjust this value appropriately 1 Press the...

Страница 8: ...units Segmented display Figure 2 Full Value Sets the maximum weight of a full bin either in pounds or kilograms It is how much material the bin can hold This is for calibration of the LED bar graph le...

Страница 9: ...the current Minute Segmented display Station ID Value Sets the Station ID of the device For devices interfacing with a Site Console the Station ID must be set within 100 131 When interfacing the devic...

Страница 10: ...CT key to see the software version number Segmented display Smart Summing Box Software Version Version 3 0 and higher Displays each of the connected Smart Summing Boxes programmed software version num...

Страница 11: ...h run control status run or Stop 6 Use the or keys to enable or disable batch run control 7 Press SELECT to start Batching if run was selected The batch run will begin immediately Scheduled Batch Run...

Страница 12: ...while a batch is running and the weight increases by 50 lbs or more in the bin the BinTrac WBBS will pause the batch and switch to FILL batching mode until FILL is completed 4 The unit will remain in...

Страница 13: ...oadcell no bin This means that the Smart Summing Box for the selected bin is not communicating Check for broken wires or loose connections or Smart Summing Box is not correctly configured or faulty lo...

Страница 14: ...ranty sets forth Buyer s sole and exclusive remedies for any defect in the goods The rights and obligation under this warranty may not be assigned or delegated to a third party by Buyer without the pr...

Отзывы: