4.3.1
Three-phase power connection
The unit is delivered without a power cable and with a three-phase terminal
connection.
1.
Prepare the connection cable (cable type H07RN-F compliant with
EN-Norm).
2.
Remove the back panel.
3.
Pass the connection cable through the strain relief screws into the
unit.
4.
Tighten the strain-relief screws securely so that the power cable
cannot be pulled out.
5.
Connect the power cable to the terminals.
6.
Remount the back panel.
4.3.2
Single-phase power connection (only SpaceSaver)
The unit is delivered without a power cable and with a three-phase terminal
connection.
NOTICE
Size 605 units in the 380 V, 400 V and 415 V versions can also be
single-phase connected.
The unit's connected output is reduced with a single-phase connection
(see
Chapter “Specifications, power supply”, Page 13
Global Foodservice Solutions
Planning and installation instructions
24
Space
$aver
™
Electricity