11
-
30
-
10
FM07-8
64
-A
McDonald’s Alert Guide
FILTER ERROR “IS POT FILLED?”
= During the AIF procedure, the display may
show “IS POT FILLED?”. If the vat is full, press the
button to resume normal
operation. If the vat is not full, press the X button for “NO” and the fryer will pump
for 30 seconds more, then the display again shows “IS POT FILLED?”.
Note: To avoid getting this message make sure filter pan is cleaned at least daily,
filter pad is changed, JIB is full, and “O” rings are in good condition.
“CHECK PAN”
= Filter pan is not locked in place.
“CHANGE FILTER PAD”
= Filter pad has not been changed within 25 hour time
period.
ELECTRIC FRYERS ONLY! “E-31” “HEATING ELEMENTS ARE UP”
= Heating
elements have been left up during maintenance filter. Lower heating elements.
ELECTRIC FRYERS. “E-10” “HI LIMIT TRIPPED”
= Allow heating elements to cool
for 15-20 minutes and r
eset high limit by pressing down and releasing raised side
of the switch for the vat that is not operating. Switches are located behind right
door next to JIB. If high limit does not reset, call for service. See ELECTRIC
FRYERS photo below.
GAS FRYERS. “E-10” “HI LIMIT TRIPPED”
= Allow fryer to cool for 15-20 minutes
and r
eset high limit by pressing
red reset button under right side of the controls
; if
high limit does not reset, call for service. See GAS FRYERS photo below.
ELECTRIC FRYERS
GAS FRYERS
GAS FRYERS ONLY! “E-20” “NO DRAFT” “CHECK FAN
”
=
Check the fryer flue and
hood system for obstructions; have the vacuum switch checked
FRYER ON BUT NOT HEATING OR “E-22” “NO HEAT”
= Vat unplugged or circuit
breaker off
Henny Penny Technical Support Hotline:
1-800-417-8405
or 937-456-8405