![Henny Penny EPC-2 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/henny-penny/epc-2/epc-2_operators-manual_2124130012.webp)
Model EPC-2, EPC-3 & EPC-4
The EPC-2 is available from the factory as a 120 or 208 VAC,
1 phase, 60 hz. unit, or a 230V, 1 phase, 50 hz. unit.
The EPC-3 & EPC-4 is available from the factory as a 208 or
240 VAC, 3 phase, 60 hz. unit, or a 400V, 3 phase, 50/60 hz. unit.
The data plate, located on the rear, interior of the unit, specifies the
correct electrical supply. The unit requires a grounded receptacle
with a separate electrical line protected by a fuse or circuit breaker
of the proper rating.
To avoid electrical shock, the cabinet must be adequately
and safely grounded (earthed) according to local electri-
cal codes, and this appliance must be equipped with an
external circuit breaker which will disconnect all un-
grounded (unearthed) conductors. The main power
switch on this appliance does not disconnect all line
conductors.
(FOR EQUIPMENT WITH CE MARK ONLY!)
To prevent electric shock hazard this appliance must be
bonded to other appliances or touchable metal surfaces in
close proximity to this appliance with an equipotential
bonding conductor. This appliance is equipped with an
equipotential lug for this purpose. The equipotential lug is
marked with the following symbol
2-5. ELECTRICAL
CONNECTION
2-6
1109
Содержание EPC-2
Страница 2: ......
Страница 9: ...Model EPC 2 EPC 3 EPC 4 408 2 3 2 4 CABINET DIMENSIONS EPC 2 ...
Страница 10: ...Model EPC 2 EPC 3 EPC 4 2 4 CABINET DIMENSIONS Continued EPC 3 In Line short EPC 3 tall 2 4 408 ...
Страница 11: ...Model EPC 2 EPC 3 EPC 4 2 4 CABINET DIMENSIONS Continued EPC 4 In Line short EPC 4 tall 408 2 5 ...