6.2.7 Global Parameters Mode
Overview
Global parameters mode allows the user to: 1.) modify the factory set global parameters and 2.)
reset the rotary dispense station to its factory default setting for the global parameters
and
all
programs.
Key Definition
MODE – to cycle between different modes. Pressing the button in global parameters mode will
bring you to auto mode.
NEXT - which allows you to toggle between the four global parameters.
UP ARROW – increases the value for a global parameter.
DOWN ARROW – decreases the value for a global parameter.
Notice:
If it is desired to return to the factory default settings for the global parameters and
all programs, hold both the up and down arrow at the same time for 5 seconds or until you see
the following message appear on the display screen, “All program and global parameters reset”.
Once this message appears you are automatically put into auto mode.
24