Must be purchased separately:
Loctite Part Number
Syringe
Cartridge
Accessory
10 ml
30 ml
55 ml
300 ml
Mounting Bracket (required)
98316
98316
98316
98318
Syringe Adapter (required)
98320
N/A
N/A
N/A
Dispense Tip Connectors (required)
N/A
N/A
N/A
982644
97233
Air Line Adapter (required)
97208
97245
97245
98319
Clear Syringe Barrel Kit (optional)
97207
97244
98314
N/A
Black Syringe Barrel Kit (optional)
97263
97264
98315
N/A
1. Insert the ¼” tube x ¼” NPT fitting to the “DISPENSE OFF” connection.
Notice:
When installing fittings be sure to hold the silver bulkhead fitting in the back of
the unit with one wrench and tighten the fitting being installed with a second wrench.
2. Insert the ¼” tube plug in the “DISPENSE OFF” connection.
3. Insert the large black plastic quick disconnect fitting to the “DISPENSE ON” connection.
4. Insert the air line adapter into the quick disconnect fitting to the “DISPENSE ON” connection.
5. Connect the air line adapter to the syringe or cartridge.
6. Add the dispense tip onto the syringe or cartridge. For the cartridge, it will be necessary to install
the cartridge adapter Part No. 982644 and luer lock adapter Part No. 97233 before connecting the
dispense tip.
7. Slide the mounting bracket over the mounting rail on the slide assembly and secure it in position
with the white nylon thumbscrew.
8. Manually pull the slide down to the fully extended position.
9. Adjust the height and position of the mounting bracket to the approximate position desired. To
adjust the position, turn the handle on the clamp blocks counter clockwise, set the position and then
secure by turning the handle clockwise.
10. Slide the syringe or cartridge into the mounting bracket and secure it using the black thumbscrews.
Caution!
It is important to ensure that the dispense tip will not crash with the mounting
plate, fixture or part. Please ensure that the height is set to avoid crashes.
11. Set the “POWER” switch to off (in the position marked “0”), the “DISPENSE PRESSURE” to 0
psi (turn the knob counter-clockwise until it stops) and the “VACUUM” off (turn the knob
clockwise until it stops).
12. Reset the “EMERGENCY STOP” by rotating it in either direction and pulling it out.
Warning!
When the emergency stop is reset, the slide may retract. Be sure to keep
your hands and other objects clear of the slide before resetting the emergency stop.
13. The single rotary dispense station is now ready to be programmed.
4.3.2 98009 Light Cure and 98013 Cyanoacrylate Dispense Valves
Warning!
Before integrating any dispensing equipment, please press the “EMERGENCY
STOP” button. This will dump the pressure to all pneumatic devices and allow the slide to
advance eliminating the potential for pinch points. It will also allow the syringe, cartridge or
valve to be installed when the slide is advanced minimizing the potential for crashes.