![Heng Hui IAD-H200 Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/heng-hui/iad-h200/iad-h200_user-manual_2123833023.webp)
Intelligence Aided Lifting Equipment
23
3.3 Description of signal cable pins of the host
3.4 Initial start
1.
When the power is turned on and the equipment detects power, “Starting...” is displayed
on the LCD.
2.
Release the emergency stop button on the front of the handle.
3. After the system startup is completed, “Position Data”, “Lockup Mode” and “Load Data”
are displayed on the LCD screen.
4.
Standard operation - sliding handle:
Hold the hand shank sliding handle and adjust
the device up and down, repeat it for several times to feel the moving of device. The
LCD shows “mode of manual hold” and the position data of the handle will be displayed
in the “position data” column. Affected by the acceleration, the load data value will
change slightly.
5.
Standard operation - CVT handle:
Hold the CVT handle and press the UP/DOWN
buttons to feel the movement of the equipment. The LCD shows “mode of manual hold”
and the position data of the handle will be displayed in the “position data” column.
Affected by the acceleration, the load data value will change slightly.
6.
Standard operation - full touch handle:
Apply an upward/downward force on the
handle operating end. When the force applied satisfies the set starting operating force
value, the system switches from “locking mode” to “mode of manual hold” and the
device starts to operate. The greater the force applied, the faster the equipment will
operate.
Pin No.
Pin
Description
1
D24V
Common power output
24v
2
CANO
H
CAN
communication
high signal
3
CANOL CAN
communication
low signal
4
COM
Common terminal
5
ESTOP
Emergency stop signal
6
PE
Grounding terminal
7
null
8
null