BPK
–
Probe™
Shaft Voltage Detection Device
Страница 1: ...Page 1 of 7 BPK Probe Shaft Voltage Detection Device ...
Страница 2: ...urces of danger When using electrically powered or controlled machines the equipment as well as the electrical system itself must be properly grounded High pressure systems too need careful inspection and maintenance to prevent possible failure from pulsation vibration or leaks Such a failure could cause among other things explosions or flying objects While never a substitute for appropriate machi...
Страница 3: ...real time visual test results On Board memory stores test data plus the Probe includes a BNC output for closer analysis of captured test data on an included Tablet Oscilloscope Thin Sensor Tip design for ease of accessability with field replaceable Sensor Tips Two quick exchange Extension Tubes for hard to access motor shafts USB Memory Stick and Micro SD Card and Reader for downloading test resul...
Страница 4: ...rding downloading test results For a more detailed analysis of the data captured by the BPK Probe it includes a BNC output and cable that are easily connected to the included tablet oscilloscope To Start a Verify the motor shaft contact area is clear of debris oils and contamination b Using the rubber flap side of the Probe Preparation Tool Figure 3 identify a contact area on the shaft for measure...
Страница 5: ...To Test a With the ground clamp safely secured press and release the Trigger Switch to activate the Probe Verify the rocker switch is off LED not lit and there is no Ground ICON displayed at the top of the screen This disables the embedded grounding brush Figure 7 To capture test data ensure the SD ICON is active b Note The BPK Probe will automatically shut off after 30 seconds of idle time To rea...
Страница 6: ...th the BPK Probe sensor tips against the motor shaft press and hold the trigger switch The Helwig Carbon logo will show Figure 10 Next a sampling screen will appear Figure 11 continue to hold the trigger switch When sampling is complete the screen will show a real time test result Figure 12 Release the trigger Figure 10 Figure 11 Figure 12 g Carefully remove the probe from the motor shaft note the...
Страница 7: ...ed to show the effectiveness of the Helwig grounding solution Figure 14 Figure 12 Figure 13 Figure 14 b If when testing with the embedded Ground Switch enabled green LED lit the result is a Grounding Error Figure 15 please verify the ground wire and clamp are properly and securely connected to a ground source If the Grounding Error persists have a qualified electrician verify the motor and motor d...