Helo 1118-60-0405 Скачать руководство пользователя страница 1

 

Main switch

INSTALLATION AND USER INSTRUCTIONS 

 
ELECTRICAL SAUNA HEATER:

   1118-60-0405 

   1118-90-0405 

 

C

 

an be connected to the following control unit: 

 RA 18  Midi control unit  
 RA 12  Digi II control unit 
 RA 13  Digi I control unit 
 RA 16  Easy control unit 
 

INSTALLATION OF THE SAUNA HEATER 

The following points have to be observed when installing the heater: 

Adhere to the given installation measurements. 

Wood panelling is recommended as material for the walls and ceiling of the sauna. 

Ensure that the panel wall has been reinforced at the point of the fixing screws. 

Only one heater may be installed into a sauna. 

The heater must only be connected to the mains by a qualified person as defined by current 
electricity regulations. 

 

NOTE! 

Prior to switching the heater on, ensure that the sauna room is ready for heating.

 

 
CONNECTING THE HEATER TO THE MAINS 

The heater is semi-connected to the mains with H07RN-F (VSN) or A07BB-F(VSB) rubber cable.  

 
HEATER STONES 

We recommend that the heater stones are cleaned before placing them onto the heater. The largest stones are placed 
at the bottom and the smallest on the top. Stones must not be structured too tightly, or air circulation is inhibited. Nor 
must the stones be placed so that heat resistance elements become wedged together or against the heater body. The 
stones must completely cover the heat resistance elements. The stones have to be replaced at the latest when they 
start to crumble, because otherwise the air circulation through the stones is affected. When replacing the stones, new 
stones have to be of a high quality. 

 
NOTE!  
- The heater stones MUST NOT be placed in the space between the front soapstones and the first resistance 
element. 
- Before use it must be checked that the soapstones in the heater are undamaged and installed according to 
instructions.

 

Otherwise the use of the heater is prohibited. The guarantee does not cover faults due to poor 

air circulation caused by small and tightly packed stones.

 

Ceramic stones may damage the heater.

 

The 

guarantee of the heater does not cover any damage caused by their use. 

 

INSTALLATION OF THE CONTROL UNIT AND SENSOR ELEMENTS

 

The control unit is electrically connected via a cable to the heater. The control unit is intended for installation in the 
sauna room or outside of it, depending on the model of the control unit. Check the control unit location from the control 
unit installation and user instructions. 
The sensor is fixed to the wall of the sauna, directly on the middle line of the heater, 40mm from the ceiling. Any 
deviation from the given installation measurements will cause a risk of burns. 
The temperature limiter in the sensor element cuts off all the heating energy to the heater if the heater temperature 
increases to a level where it causes a danger to the wooden parts of the sauna. Once the temperature is reduced the 
limiter can be restored by pressing the restore button. 

Before pressing restore, the reason for the triggering of the temperature limiter must always be clarified!

 

Restore

Sensor OLET 19

 

 

7013482   314 SKLT 3 B 
 
 
 

Содержание 1118-60-0405

Страница 1: ...crumble because otherwise the air circulation through the stones is affected When replacing the stones new stones have to be of a high quality NOTE The heater stones MUST NOT be placed in the space b...

Страница 2: ...locking pieces for the heater A 2 pieces wall fastener B 1 piece metal screw 4 2 x 13mm 2 pieces cover screw 6 x 40mm 2 pieces Fit the locking pieces A for the heater into the holes in the back plate...

Страница 3: ...ot crack even at high temperatures 1 The first heating Set the heater to approx a 50 C setting for about an hour Then disconnect the heater and let the stones cool down 2 The second heating Set the he...

Страница 4: ...ple through the wall the entry valve is placed in area B and the exit valve at least 1m higher and as far as possible from the heater Due to the sensor element OLET 19 location placing of the entry va...

Страница 5: ...aunabeleuchtung Sauna light max 100W 3 Tuuletin Fl kt Ventilator Fan max 100W 4 S hk l mmityksen vuorottelu El f rregling av annan el f rbrukare Signal kontakt Signal contact 5 Ohjauskeskus Styrpanel...

Страница 6: ...II 2002 Sensor Input 400V 3N Heater Principal wiring diagram N N 55 Sauna light 230V 100W Fan 230V 100W Electrical heating Control 230V NOTE Not with the RA 18 Midi control centre or RA 16 Easy contro...

Страница 7: ...e placed Install the intermediate pieces 8 of the soapstones so that the projection will always stay on the stone i e there will always be an air gap between the stones The metal pieces are placed on...

Страница 8: ...ed Install the support rods between the vertical limiters The soapstones also remain between the vertical limiters End limiter The illustration shows the installed support rods The soapstones are inst...

Страница 9: ...the back remain where they are The illustration shows both the vertical and horizontal limiters of the soapstones Install the middle stones The length of the middle stones is 405mm Push the stone fir...

Отзывы: