![Helmholz 700-672-PNC01 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/helmholz/700-672-pnc01/700-672-pnc01_manual_2122269037.webp)
PN/CAN Gateway, PROFINET/CANopen Slave | Version 2 | 1/26/2021
37
10
Technical data
Order no.
700-672-PNC01
Name
PN/CAN Gateway, PROFINET/CANopen Slave
PROFINET interface
Protocol
PROFINET IO device as defined in IEC 61158-6-10
Transmission rate
100 Mbps full duplex
I/O image size
1440 bytes
Connection
2x RJ45, integrated switch
Features
PROFINET Conformance Class C,
Media redundancy (MRP client),
Automatic addressing,
Topology detection (LLDP, DCP),
Diagnosis alarms
CAN interface
Type
ISO/DIN 11898-2 CAN High-speed physical layer
Connection
9-pin D-sub male connector
Protocol
CANopen Slave as defined in DSP301 V4.2
Baud rate
10, 50, 100, 125, 250, 500, 800, 1000 kbps
TPDOs/RPDOs
16 / 16
Features
NMT, Nodeguarding/Heartbeat, Sync, Emergencies
Electrical isolated from CAN-bus
Yes; Isolation 5 kV
USB interface
Protocol
Full-speed USB 2.0 device
Connection
Mini-USB
Electrically isolated from USB
Yes; isolation 5 kV
Voltage supply
24 V DC, 18–28 V DC
Current draw
Max. 250mA
Dimensions (D x W x H)
35,5 x 83,5 x 76 mm
Weight
Approx. 160 g
Certifications
CE, PROFINET certification
Noise immunity
DIN EN 61000-6-2 “EMC Immunity”
Interference emission
DIN EN 61000-6-4 “EMC Emission”
Vibration and shock resistance
DIN EN 60068-2-6:2008 “Vibration”
DIN EN 60068-2-27:2010 “Shock”
Protection rating
IP 20
Relative humidity
95% without condensation
Installation position
Any
Permissible ambient temperature
0° C to 60° C
Transport and storage temperature
-20° C to 80° C