background image

HELLENBRAND, INC.

404 Moravian Valley Road 

Waunakee, Wisconsin 53597-0187

Phone (608) 849-3050

Fax (608) 849-7398

Arsenic Facts

Arsenic  (As)  is  a  naturally  occurring  contaminant  found  in  many  ground  waters.  It  generally 

occurs  in  two  forms  (valences  or  oxidation  states):  pentavalent  arsenic  (also  known  as 

As(V),  As(+5),  or  arsenate)  and  trivalent  arsenic  (also  known  as  As(III),  As(+3),  or  arsenite). 

In  natural  ground  water,  arsenic  may  exist  as  trivalent  arsenic,  pentavalent  arsenic,  or  a 

combination of both. Although both forms of arsenic are potentially harmful to human health, 

trivalent arsenic is considered more harmful than pentavalent arsenic. More information about 

arsenic and its toxicity can be found on the U.S. Environmental Protection Agency website at:

http://www.epa.gov/safewater/arsenic.html.

This system is designed to remove only pentavalent arsenic. This treatment system does not

provide a feature for conversion of trivalent arsenic to pentavalent arsenic. The system may 

remove some trivalent arsenic; however, it has not been evaluated for its ability to remove 

trivalent arsenic.

Trivalent arsenic is generally more difficult to remove from drinking water than pentavalent arsenic. 

Trivalent arsenic can be converted to pentavalent arsenic in the presence of an effective oxidant 

such as free chlorine. The arsenic in water containing detectable free chlorine or that has been 

treated  with  another  effective  oxidant  will  be  in  the  pentavalent  arsenic  form.  Treatment  with 

chloramine (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic 

to pentavalent arsenic.

Consumers using public water supplies can contact their utility to verify whether free chlorine 

treatment chemicals are being used. Private water supplies and waters that do not have detectable 

free chlorine residuals should be analyzed to determine the form(s) of arsenic present and the 

potential need for oxidation of trivalent arsenic to pentavalent arsenic.

Arsenic does not generally impart color, taste or smell to water, therefore, it can only be detected 

by a chemical analytical test. Public water supplies are required to monitor treated water for total 

arsenic (trivalent arsenic plus pentavalent arsenic) and the results are available to the public from 

the utility. Consumers using private water sources will need to make arrangements for testing. A 

total arsenic test usually costs about $15-$30 and it is recommended the test be conducted by 

a certified laboratory. Local health departments or environmental protection agencies can help 

provide consumers with a list of certified laboratories. Some laboratories may also be able to analyze 

specifically for (speciate) the two forms of arsenic present in a water sample if requested. 

This treatment system was tested under laboratory conditions as defined in NSF/ANSI 58 Reverse 

Osmosis Drinking Water Treatment Systems and was found to reduce 0.30 mg/L influent arsenic 

challenge  concentration  in  the  test  water  to  less  than  0.010  mg/L,  under  standard  testing 

conditions.  Actual  performance  of  the  system  may  vary  depending  on  specific  water  quality 

conditions  at  the  consumer’s  installation.  Following  installation  of  this  system,  the  consumer 

should have the treated water tested for total arsenic to verify arsenic reduction is being achieved 

and the system is functioning properly.

The pentavalent arsenic removal component of this system (the R.O. membrane) must be replaced 

at the end of its useful life. Typical membrane life expectancy is three years. Local conditions may 

dictate more frequent changes. For replacement parts contact the local dealer who supplied the 

unit or contact the factory for the dealer nearest you.