5
Send
telegrams specification
Triton OMD CAN protocol / Rev.-No. 03
13
5.5
Sensor configuration data telegram
Command:
51
Data bytes:
8
Destination:
from master
individual sensor.
Timeout:
not periodical telegram
Activation:
automatic, if all the following conditions are fulfilled:
•
Sensor configuration is invalid;
•
Sensor configuration sequence is in process;
•
Sensor is online.
Command: 51
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
High byte
Low byte
High byte
Low byte
High byte
Low byte
High byte
Low byte
Data item
Configuration Parame-
ter 1 Value
Configuration Parame-
ter 2 Value
Configuration Parame-
ter 3 Value
Configuration Parame-
ter 4 Value
Tab. 5.5 Command 51
Telegram function details are described in section
7.4 Individual sensor configuration
5.6
Sensor internal function execution request telegram
Command:
84
Data bytes:
2
Destination:
common designated message from master to all sensors.
Timeout:
not periodical telegram
Activation:
It is masters responsibility to activate the transmission of this telegram.
In HEINZMANN OMD evaluator device it activated with DcDesk option
“Error – Clear errors” or corresponding GUI option.
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
High byte
Low byte
High byte
Low byte
High byte
Low byte
High byte
Low byte
Data item
Internal function exe-
cution command
-
-
-
-
-
-
Tab. 5.6 Command 84
Telegram function details are described in section
7.5 Sensor internal function execution re-
Содержание Triton OMD
Страница 2: ......
Страница 8: ......
Страница 12: ...2 System description 4 Triton OMD CAN protocol Rev No 03...
Страница 16: ...3 HEINZMANN CAN protocol 8 Triton OMD CAN protocol Rev No 03...
Страница 22: ...5 Send telegrams specification 14 Triton OMD CAN protocol Rev No 03...
Страница 26: ...6 Receipt telegram specification 18 Triton OMD CAN protocol Rev No 03...