Heinrichs BGK Скачать руководство пользователя страница 1

 

 

 
 

 

Variable-Area Flowmeters 

 

 

KDS 
BGK

 

 

 

Operating Instructions 

 
 

 
 
 

 
 
 

BGK 

KDS-S 

KDS-K/C 

KDS-R

 

 
 
 
 

BGK 

Содержание BGK

Страница 1: ...Variable Area Flowmeters KDS BGK Operating Instructions KDS S KDS K C KDS R BGK...

Страница 2: ...cy 5 6 1 Reference conditions 5 6 2 Measured error 5 6 3 System deviation for KDS R 5 6 4 Repeatability 5 6 4 1 KDS R regulator 5 6 5 Influence of ambient temperature 5 6 6 Influence of fluid temperat...

Страница 3: ...Available accessories 11 13 Order information 11 14 Use in hazardous areas 12 14 1 Atmospheric conditions 12 14 2 Electrostatic charge of non conductive parts 12 14 3 Ground connection 12 14 4 Mechani...

Страница 4: ...ish equilibrium The height of the float is a measure of the flow quantity 3 2 BGK and KDS K C S system design The meter consists of a conical fitting pipe with a float that can move vertically The pos...

Страница 5: ...16 l h 48 480 l h 350 12 9 F 2 5 25 l h 75 750 l h 350 17 10 G 4 0 40 l h 120 1200 l h 350 25 11 H 6 0 60 l h 180 1800 l h 350 45 12 I 10 100 l h 300 3000 l h 350 95 15 only KDS S BGK J 16 160 l h 480...

Страница 6: ...dequately stable to rule out the possibility of vibration or swinging Do not use steel mounting parts on the device If there is risk of dirt or solid matter penetrating the process pipes flush them be...

Страница 7: ...BGK without limit transducer 40 C to 130 C with limit transducer 25 C to 100 C 7 3 2 Fluid temperature range KDS R 10 C to 100 C 7 3 3 Fluid pressure limit KDS K C PN 40 special version up to PN 160...

Страница 8: ...llic wetted parts are made of 1 4404 316L stainless steel The measured values are transmitted magnetically to the analog indicator unit mounted on the device KDS K process connections horizontally tow...

Страница 9: ...le area flowmeter with a setting valve and a differential pressure regulator mounted on the meter The measured value is displayed on the scale of the analog indicator unit The desired flow rate can be...

Страница 10: ...Heinrichs Messtechnik KDS BGK Operating Instructions Page 10 of 19 8 5 BGK with flange connection...

Страница 11: ...ant The mounting lengths may be differerent Other connections are available a special versions BGK Flanges DN15 25 ANSI 1 Other flanges are available as special versions 9 Electrical connection 9 1 Wi...

Страница 12: ...on Static charge possible At cleaning and maintenance works taking into account To clean these devices use a wet wiper 14 3 Ground connection In variable area flow meters it is possible under operatin...

Страница 13: ...eets the statutory requirements of the following EU directives Directive 94 9 EC Equipment and Protective Systems for Use in Potentially Explosive Atmospheres and Electromagnetic Compatibility EMC Dir...

Страница 14: ...its intended purpose However if cleaning is necessary to remove dirt from the measuring ring or the float take note of the following aspects Before removing a device make sure that the pipeline is fr...

Страница 15: ...measured medium Since this measured medium is dangerous in water poisonous corrosive flammable we have checked that all hollow spaces of the device are free of these materials neutralized and flushed...

Страница 16: ...Heinrichs Messtechnik KDS BGK Operating Instructions Page 16 of 19 23 EC Type Examination Certificate of the inductive sensor...

Страница 17: ...Heinrichs Messtechnik KDS BGK Operating Instructions Page 17 of 19...

Страница 18: ...Heinrichs Messtechnik KDS BGK Operating Instructions Page 18 of 19 24 Notes...

Страница 19: ...tmospheres Part 1 Basic method and requirements F r angebaute elektrische Sensoren For add on electrical sensors EN 60079 0 General requirements EN 60079 11 Intrinsic safety i EMV Richtlinie 2004 108...

Отзывы: