background image

 

11 

 

GASOLINE GENERATOR 

8

TROUBLESHOOTING 

 
The engine does not start: 

 

 
Is there fuel in the tank? 
 

NO 

 
Refill the fuel tank. 

 
 

 

YES 

 

 

 
Is there engine switch on? 
 

NO 

 
Turn the engine switch on. 

 
 

 

    YES 

 

 
Is the fuel valve on? 
 

NO 

 
Turn the fuel valve on. 

 
 

 

YES 

 

 

 
Is there enough oil in the engine? 

NO 
(The oil alert lamp goes on when pulling 
the start grip.)  

 
Add the recommended oil 

 

 

 

 

 

   

YES 

 

 

 
Is there a spark from the spark plug? 
 

NO 

 
Take the generator to an authorized 
dealer. 

 
 
 
 
 
 
 
 
 
 
 

 

YES 

 

 

 
Is the fuel reaching the carburetor? 
 

NO 

 

Clean the fuel filter cup. 

 
 

 

    YES 

 

 
If the engine still does not start, take the 
generator to an authorized dealer. 
 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

Replace the spark 

plug. 

WARNING!

  Be  sure  there  is  no  spilled 

fuel  around  the  spark  plug.  Spilled  fuel 
may ignite.  

To check: 
1) Remove the spark plug cap and clean 
any dirt from around the spark plug. 
2) Remove the spark plug and install the 
spark plug in the plug cap. 
3)  Set  the  plug  side  electrode  on  the 
cylinder head. 
4)  Pull  the  recoil  starter,  spark  should 
jump across the gap. 
  
 

To check: 
1) Turn on the fuel valve and remove the 
drain screw. 
2) Fuel should flow from the drain when 
the fuel valve is turned on. 
 

Содержание VGEN002

Страница 1: ...www heinner com VGEN002 Instructions GB Instruc iuni de utilizare RO...

Страница 2: ...om the generator set 4 Refilling of the generating sets are not allowed during the operation 5 If the generator will be mounted in a closed room relevant safety regulations against fire and explosion...

Страница 3: ...ing engine performance and life Use the 4 stroke oil SAE10W 40 is recommended for general all temperature use Other viscosities shown in the chart may be used when the average temperature in your area...

Страница 4: ...er part of fuel filter Fix the fuel tank cap 3 STARTING THE ENGINE 1 Disconnect any load from the AC socket and turn off the alternating current circuit breaker 2 Turn the fuel valve to ON position 3...

Страница 5: ...connection 2 Electrical equipment motor driven devices will produce lots of electric current when they start The following form will give you a reference when you connect them to generator Mode Amoun...

Страница 6: ...tion networks the total length of lines for a cross section of 1 5 mm2 should not exceed 60 m for a cross section of 2 5 mm2 this should not exceed 100 m Notice When you want to connect the generator...

Страница 7: ...h or operating hour interval whichever occurs first ITEM Daily First month or 20 Hrs Every 3 months or 50 Hrs Every 6 months or 100 Hrs Every year or 300 Hrs Engine oil Inspection Change Air cleaner e...

Страница 8: ...ase dispose of used motor oil in a manner that is compatible with the environment We suggest you take it in a sealed container to your local service station for reclamation Do not throw it in the tras...

Страница 9: ...spark plug must be properly gapped and free of deposits 1 Remove the spark plug cap 2 Clean any dirt from around the spark plug base 3 Use the wrench supplied in the tool kit to remove the spark plug...

Страница 10: ...y tightened plug can become very hot and possibly damage the generator Never use a spark plug with an improper heat range 4 Fuel filter service The filter prevents dirt or water which may be in fuel t...

Страница 11: ...remove and empty the filter cup b Turn the fuel valve ON and drain the gasoline in the fuel tank into a suitable container c Replace the filter cup and tighten securely d Loosen the carburetor drain s...

Страница 12: ...he fuel reaching the carburetor NO Clean the fuel filter cup YES If the engine still does not start take the generator to an authorized dealer Replace the spark plug WARNING Be sure there is no spille...

Страница 13: ...ASOLINE GENERATOR Model XXXX Displacement 210CC 4 stroke AC voltage 230 50Hz Rated Power Output 2 8kw Max Power Output 3 0kw Speed 4000 r min Fuel Tank Capacity 12 2L Continuous operating time 10 hour...

Страница 14: ...mental protection requirements in your country Petrol oil and petrol oil mixtures are hazardous waste and have to be treated as such Oil and fuel must not be disposed of with household waste Improper...

Отзывы: