Heiman HS1DS-Z Скачать руководство пользователя страница 1

智能门磁探测器中性英文说明书

CZZN 2016010501

2016-3-17

物料编号

mm

文件编号

1:1

图      幅:

1

/

1

邹喜林

HS1DS-Z

制作要求:

1

、制作尺寸:

330

*

55mm

2

、六折扇形折页折法,折叠后尺寸为

55

*

55mm

3

120g

铜版纸彩色印刷

Smart Door Sensor

User  Manual

T

e

c

h

n

ic

a

P

a

r

a

m
e

te

r

s

F

u

n

c

ti

o


r

e

n

d

e

r

in

g

s

P

ro

d

u

c

D

e

s

c

rip

tio

n

55mm

55mm

5

5

m

m

5

5

m

m

55mm

55mm

55mm

*

Please read the user manual carefully before operation.

The guide picture is for reference only, please in kind prevail.

      

This is a intelligent door sensor , adopts super 

low power Z-Wave wireless networking technology, 
makes  a  longer  battery  life-span,  Feel  open  or 
close  state  of  the  door  or  window  through  the  near 
and  separation  between  sensor  and  magnetic. 
Dual  sensor  design,  makes  the  installation  more 
flexible  and  adaptable.  Products  are  suitable  for 
home,  villas,  factories,  shops,  warehouses,  office 
buildings,  banks,  room  and  other  places  of  safety 
prevention. 

M417-1Ever1.0

M417-1

E

ver1.0

Sensor

Magnet

Networking Indicator

Align the installation, the installation distance is less
than 15mm. (The magnet part can be installed both 
sides of detector part)

Tear  off  the  gummed  film,  stick  the  equipment  on  the  required  area.
Sensor  should  be  installed  in  fixed  area  like  door  frame, magnet  can 
 be installed in active area like door plank, this picture for reference only.

Click the “add” button to enter the networking mode.

Long press the networking button,then power on (put into
battery),ID code is clear and recover to factory setting.

R

e

s

to

re 

fa

c

to

ry 

s

e

tti

n

g

s

55mm

1

2

3

4

5

7

6

8

9

10

11

Connecting network: According to the APP tip, press the device 
networking hole for 3 times in 1.5 seconds, then the green LED 
flashes  quickly  (connecting  network  within    30  seconds),  and 
“networking succeed “ will be displayed on app interface.
Disconnecting network: Click the “delete device” button on APP, 
then  quick  press  networking  hole  for  3  times  in  1.5  seconds, 
green LED flashes for 6 times, disconnecting network succeed.

Anti-tamper key

B

a

tte

ry 

re

p

la

c

e

m

e

n

t

Step 1

Step

 

2

Please change the battery according to negative 
and positive of the battery.
Please deal with waste batteries correctly for 
environmental protection.

Step 3

Step 4

Step 5

+

-

+

-

+

+

-

-

+

+

-

-

+

-

+

-

Remove insulator make device on power.

1.

DC3V 

(

2 pcs AAA battery 

)

2

:≤

5uA

3

:≤

35mA

4

:>

20mm

Z-Wave 

  

6

:≥

70 metres 

9

16.5

 

mm

Working Voltage

Static current

Alarm current

Detecting distance

Networking

Ad-Hoc Network

Wireless networking distance

in 

  the open area

Working environment

Working humidity

maximum 95%RH

No 

   condensation

Detector dimension

Magnet dimension

.

.

.

5.

.

7.

:-

10

℃ ~ +

50

℃;

8.

.

76 * 36.6

10.

76 * 13.9

16.5

 

mm

601010835

Please use the reset procedure only when the 
primary controller is missing or inoperable.

Association Group

:

 

Lifeline association group

Group Number: 1     Maximum Nodes:5
Description: Include command classe: Battery report, Notification report, and
 Device Reset Locally notification, Binary report.

Association Group

:

 

Root Device group(Binary Sensor)

Group Number: 2    Maximum Nodes:5
Description: Binary Sensor Command Classes:Compatible with 300 series
1-Binary Sensor reports status of open or close door via Lifeline.
2-When the sensor detects status change between close door and open door,
 the device will be triggered. 

Association Group

:

 

Root Device group(Binary Sensor)

Group Number: 3    Maximum Nodes:5
Description: Binary Sensor Command Classes:Compatible with 300 series
1-Binary Sensor reports the removed status of door sensor.
2-When the sensor detects status change of tamper, the device will be triggered. 

Association Group

:

 

Root Device group(Notification)

Group Number: 4    Maximum Nodes:5
Description: 1-Notification report open door or close status via Lifeline.
2- When the sensor detects status change between close door and open door, 
the device will be triggered.

Association Group

:

 

Root Device group(Notification)

Group Number: 5     Maximum Nodes:5
Description: 1-Binary Sensor reports the removed status of door sensor.
2- When the sensor detects status change of tamper, the device will be triggered. 

Association Group

Отзывы: