智能门磁探测器中性英文说明书
CZZN 2016010501
2016-3-17
名
称
型
号
物料编号
版
本
材
质
单
位
:
:
:
:
:
:
:
:
:
:
:
:
mm
文件编号
日
期
制
图
审
核
核
准
比
例
1:1
图 幅:
1
/
1
邹喜林
HS1DS-Z
制作要求:
1
、制作尺寸:
330
*
55mm
2
、六折扇形折页折法,折叠后尺寸为
55
*
55mm
3
、
120g
铜版纸彩色印刷
Smart Door Sensor
User Manual
T
e
c
h
n
ic
a
l
P
a
r
a
m
e
te
r
s
F
u
n
c
ti
o
n
r
e
n
d
e
r
in
g
s
P
ro
d
u
c
t
D
e
s
c
rip
tio
n
55mm
55mm
5
5
m
m
5
5
m
m
55mm
55mm
55mm
*
Please read the user manual carefully before operation.
The guide picture is for reference only, please in kind prevail.
This is a intelligent door sensor , adopts super
low power Z-Wave wireless networking technology,
makes a longer battery life-span, Feel open or
close state of the door or window through the near
and separation between sensor and magnetic.
Dual sensor design, makes the installation more
flexible and adaptable. Products are suitable for
home, villas, factories, shops, warehouses, office
buildings, banks, room and other places of safety
prevention.
M417-1Ever1.0
M417-1
E
ver1.0
Sensor
Magnet
Networking Indicator
Align the installation, the installation distance is less
than 15mm. (The magnet part can be installed both
sides of detector part)
Tear off the gummed film, stick the equipment on the required area.
Sensor should be installed in fixed area like door frame, magnet can
be installed in active area like door plank, this picture for reference only.
Click the “add” button to enter the networking mode.
Long press the networking button,then power on (put into
battery),ID code is clear and recover to factory setting.
R
e
s
to
re
fa
c
to
ry
s
e
tti
n
g
s
55mm
1
2
3
4
5
7
6
8
9
10
11
Connecting network: According to the APP tip, press the device
networking hole for 3 times in 1.5 seconds, then the green LED
flashes quickly (connecting network within 30 seconds), and
“networking succeed “ will be displayed on app interface.
Disconnecting network: Click the “delete device” button on APP,
then quick press networking hole for 3 times in 1.5 seconds,
green LED flashes for 6 times, disconnecting network succeed.
Anti-tamper key
B
a
tte
ry
re
p
la
c
e
m
e
n
t
Step 1
Step
2
Please change the battery according to negative
and positive of the battery.
Please deal with waste batteries correctly for
environmental protection.
Step 3
Step 4
Step 5
+
-
+
-
+
+
-
-
+
+
-
-
+
-
+
-
Remove insulator make device on power.
1.
:
DC3V
(
2 pcs AAA battery
)
2
:≤
5uA
3
:≤
35mA
4
:>
20mm
:
Z-Wave
6
:≥
70 metres
)
9
:
16.5
mm
Working Voltage
Static current
Alarm current
Detecting distance
Networking
Ad-Hoc Network
Wireless networking distance
in
the open area
Working environment
Working humidity
maximum 95%RH
(
No
condensation
)
Detector dimension
Magnet dimension
.
.
.
5.
.
7.
:-
10
℃ ~ +
50
℃;
8.
:
.
76 * 36.6
*
10.
:
76 * 13.9
*
16.5
mm
601010835
Please use the reset procedure only when the
primary controller is missing or inoperable.
Association Group
:
Lifeline association group
Group Number: 1 Maximum Nodes:5
Description: Include command classe: Battery report, Notification report, and
Device Reset Locally notification, Binary report.
Association Group
:
Root Device group(Binary Sensor)
Group Number: 2 Maximum Nodes:5
Description: Binary Sensor Command Classes:Compatible with 300 series
1-Binary Sensor reports status of open or close door via Lifeline.
2-When the sensor detects status change between close door and open door,
the device will be triggered.
Association Group
:
Root Device group(Binary Sensor)
Group Number: 3 Maximum Nodes:5
Description: Binary Sensor Command Classes:Compatible with 300 series
1-Binary Sensor reports the removed status of door sensor.
2-When the sensor detects status change of tamper, the device will be triggered.
Association Group
:
Root Device group(Notification)
Group Number: 4 Maximum Nodes:5
Description: 1-Notification report open door or close status via Lifeline.
2- When the sensor detects status change between close door and open door,
the device will be triggered.
Association Group
:
Root Device group(Notification)
Group Number: 5 Maximum Nodes:5
Description: 1-Binary Sensor reports the removed status of door sensor.
2- When the sensor detects status change of tamper, the device will be triggered.
Association Group