Battery

 

Powered

 

Photoelectric

 

Smoke

 

Alarm

 

User

 

Manual

1

2

This  product  is  a  battery  operated  photoelectric  smoke  alarm, 
adopting  unique  structure  design  and  advanced  photoelectric 
sensor technology, able to monitor and detect smoke particles in 
real  time.  Especially  detects  visible  particles  (associated  with 
smouldering  fire)  sooner  than  ionization  alarms.  Once  smoke 
particles or a fire danger is detected, this alarm will chirp and the 
red  LED  will  flash  rapidly  to  alert  you  and  your  family  timely. 
Furthermore, this alarm has dustproof, mothproof and anti-light 
interference  etc.  functions,  ensuring  stability  from  design  basis 
and  suitable for early warning and protection of fires in houses, 
factories,  shopping  malls,  hotels,  office  buildings,  school 
buildings, banks, libraries and warehouses etc. indoor places. 

2

1

3

4

5

Tamper R

 

esist  Locking P

 

in  - c

 

ould b

 

e  installed  in  motor  homes,  

ships  etc .  quavering  places.
Battery  Compartment C

 

over  - o

 

n t

 

op  surface.  Battery

  

replacement i

 

s v

 

ery c

 

onvenient

Buzzer  -  loud  alarm  sound  >  85  decibel. 

Test B

 

utton   verifies i

 

f  the  smoke a

 

larm i

 

s o

 

perating  properly

.

-  

RedL

 

ED   standby  status,  flashes  once  every  40s;   alarm  status, 

 flashes  rapidly.

-  

● 

Advanced photoelectric sensing technology; detects visible 
particles (associated with  smouldering fire) sooner than 
ionization alarms.

  Convenient  to  install  and  maintain.

 Battery  compartment  on  alarm  top  surface;  battery  

replacement is more convenient  and  has  protection  function  
for  reverse  battery  loading. 

● 

Auto  check  malfunction.

● 

Low battery warning;  smoke alarm will  chirp once every 40s  

to remind user of replacing a new battery.  

● 

Auto  reset.

● 

Sound and flash alarm; alarm sound louder than 85 decibel 
with  red  LED  flashing .

● 

Test  button;  tests  unit’s  electronic  circuitry,  buzzer  and  
battery  function.

● 

SMT  manufacture  technology;  high  stability.

● 

Dustproof, mothproof and anti-white light interference design.

● 

Anti-RFI  (20V/m-1GHz).

Power

 

supply: DC 9V battery

Standby current: <12µA
Alarm current: <10mA
Alarm sound: >85dB (3m)
Sensor type: Photoelectric
Battery life after low battery warning: >30days
Temperature range: 0°C ~ 49°C

 

(32°F ~ 120°F)

 

Humidity

:

 10%~90%RH

 

(No icing or condensation)

Dimension: Φ95x41mm

Executive  criteria:  EN14604:2005; GB4715-2005;  Ul217
Detecting  area:  80m  at  6-12m  installation  height;   
                            60m  at  installation  height  <6m.  

INSTALLATION

1

.

Avoid

 

installations

 

in

 

places  with  stagnating  smoke,  heavy 

dust, heavy water mist, heavy oil mist, great humidity (>95%) 
and high wind speed (>5m/s).

2. Insert  the  battery  correctly  into  the  battery  compartment 

according to the  marked positive and negative polarity. 

3. Choose a proper position. Normally the center of the detection 

area ceiling is recommended. If impractical, do not install the 
detector  in  area  without  air  flow  (as  Figure  1).  For  roof  with 
oblique  beam,  the  ceiling  is  also  oblique  where  the  detector 
should be installed at a position with 0.9m horizontal distance 
to  spire  (as  Figure  2).  Fix  the  detector  base  into  a    chosen 
position  with  screws.  Then  put  the  detector  head  into  the 
base  and  twist  clockwise  to  fasten  it  (as  Figure  3).    At  last, 
plug in the tamper resist locking pin (as Figure 4).

Figure 3

Figure 2

Figure 4

15cm

15

cm

Area without 
air flow

Figure 1

1. Battery is equipped on delivery. Unpack the battery insulation 

cement to active the battery before using.

2.  After  activating  the  battery,  the  smoke  alarm  enters  into 

normal monitoring status. The LED blinks once every 40s.

3. Sensitivity Test
    To  ensure  normal  operation,  periodic  tests  should  be 

performed. Once a month is recommended. For testing, press 
and hold the Test Button more than 3s to enter into sensitivity 
test  status.  The  alarm  indicator  will  flash  rapidly  and    buzzer 
will  give  out  alarm  sound,  which  indicates  the  smoke  alarm 
works  properly.  During  testing,  keep  ears  away  from  the 
smoke alarm to avoid hearing damage. 