Testing and running | Skipping NC blocks
6.7
Skipping NC blocks
You can have NC blocks skipped in the following operating modes:
Test Run
Program run, full sequence
Program run, single block
Positioning w/ Manual Data Input
Operating notes:
This function does not work for
TOOL DEF
blocks.
After a power interruption the control returns to the
most recently selected setting.
The setting of the
HIDE
soft key is only effective in the
respective operating mode.
Test Run and Program Run
Application
In
Test Run
or
Program Run, Full Sequence/Single Block
operating
mode, the control can skip over NC blocks that you have preceded
by a slash (
/
):
Set the
HIDE
soft key to
ON
The control skips the NC blocks.
Set the
HIDE
soft key to
OFF
The control runs or tests the NC blocks.
Procedure
You can optionally hide NC blocks.
To hide NC blocks in the
Programming
mode:
Select the desired NC block
Press the
INSERT
soft key
The control inserts a slash (/).
To show NC blocks again in the
Programming
mode:
Select the hidden NC block
Press the
REMOVE
soft key
The control removes the slash (/).
6
HEIDENHAIN | TNC 620 | User's Manual for Setup, Testing and Running NC Programs | 01/2022
261
Содержание TNC 620
Страница 4: ...Contents 4 HEIDENHAIN TNC 620 User s Manual for Setup Testing and Running NC Programs 01 2022...
Страница 6: ...Contents 6 HEIDENHAIN TNC 620 User s Manual for Setup Testing and Running NC Programs 01 2022...
Страница 24: ......
Страница 25: ...1 Basic information...
Страница 43: ...2 First steps...
Страница 55: ...3 Fundamentals...
Страница 126: ......
Страница 127: ...4 Tools...
Страница 165: ...5 Setup...
Страница 245: ...6 Testing and running...
Страница 311: ...7 Special functions...
Страница 316: ......
Страница 317: ...8 Pallets...
Страница 339: ...9 MOD functions...
Страница 368: ......
Страница 369: ...10 HEROS functions...
Страница 470: ......
Страница 471: ...11 Operating the touchscreen...
Страница 488: ......
Страница 489: ...12 Tables and overviews...