Tools | Touch probe table
4
4.2
Touch probe table
Application
The touch probe table
tchprobe.tp
defines the touch probe and data
for the touching process, e.g. the probe feed rate. If you use several
touch probes, you can save separate data for each touch probe.
Description of function
The touch probe table contains the parameters below:
Parameter
Meaning
Input
NO
Sequential number of touch probe
This number assigns the touch probe in tool table column
TP_NO
to the data.
1...99
TYPE
Selection of the touch probe?
The TS 642 touch probe makes the following
values available:
TS642-3
: The touch probe is activated by a
conical switch. This mode is not supported.
TS642-6
: The touch probe is activated by an
infrared signal. Select this mode.
TS120
,
TS220
,
TS249
,
TS260
,
TS440
,
TS444
,
TS460
,
TS630
,
TS632
,
TS640
,
TS642-3
,
TS642-6
,
TS649
,
TS740
,
KT130
,
OEM
CAL_OF1
TS center misalignmt. ref. axis? [mm]
Offset of the touch probe axis to the spindle axis in the
main axis
–99999.9999...+99999.9999
CAL_OF2
TS center misalignmt. aux. axis? [mm]
Offset of the touch probe axis to the spindle axis in the
secondary axis
–99999.9999...+99999.9999
CAL_ANG
Spindle angle for calibration?
Prior to calibrating or probing, the control aligns the touch
probe with the spindle orientation angle (if possible).
0.0000...+359.9999
F
Probing feed rate? [mm/min]
F
can never be greater than defined in the optional machine
parameter
maxTouchFeed
(no. 122602).
0...+9999
FMAX
Rapid traverse in probing cycle? [mm/min]
Feed rate at which the control pre-positions the touch
probe and positions it between the measuring points
–99999...+99999
DIST
Maximum measuring range? [mm]
If the stylus is not deflected in a probing process within the
defined value, the control will issue an error message.
0.00100...+99999.99999
SET_UP
Set-up clearance? [mm]
Distance of touch probe from the defined touch point when
pre-positioning
The smaller this value is, the more exactly you must define
the touch point position. Safety clearances defined in the
touch probe cycle are added to this value.
0.00100...+99999.99999
148
HEIDENHAIN | TNC 620 | User's Manual for Setup, Testing and Running NC Programs | 01/2022
Содержание TNC 620
Страница 4: ...Contents 4 HEIDENHAIN TNC 620 User s Manual for Setup Testing and Running NC Programs 01 2022...
Страница 6: ...Contents 6 HEIDENHAIN TNC 620 User s Manual for Setup Testing and Running NC Programs 01 2022...
Страница 24: ......
Страница 25: ...1 Basic information...
Страница 43: ...2 First steps...
Страница 55: ...3 Fundamentals...
Страница 126: ......
Страница 127: ...4 Tools...
Страница 165: ...5 Setup...
Страница 245: ...6 Testing and running...
Страница 311: ...7 Special functions...
Страница 316: ......
Страница 317: ...8 Pallets...
Страница 339: ...9 MOD functions...
Страница 368: ......
Страница 369: ...10 HEROS functions...
Страница 470: ......
Страница 471: ...11 Operating the touchscreen...
Страница 488: ......
Страница 489: ...12 Tables and overviews...