Safety
Power Switch with Emergency Stop Function
Fig. 3 Suprasetter
Automatic Cutouts
Fig. 4 Automatic cutouts
Tab. Automatic cutouts
The power switch triggers a bipolar cut-off of the
Suprasetter from the power supply. In an emer-
gency, this power switch is used as an emergency
stop switch for the Suprasetter. The power switch
with emergency stop function is located on the
right side of the Suprasetter.
WARNING
Risk of injury from improper operation during an emergency stop
The emergency stop circuits of Suprasetter machines are not connected to the
emergency stop circuit of the online processor!
Press the emergency stop on the online processor to stop the online processor.
The automatic cutouts are located at the rear of
the electric terminal box on the lower part.
F1
4A Processor board and safety loop
F2
10A Laser system, actuators, sensors, swivel table, feeder, chiller, vacuum
pumps
F3
10A Lexium drive for the drum motor
F4
4A Suction device
Содержание Suprasetter A52