background image

 
 

                                      

Product & 

Installation Manual 

HEATS TRI P

®

 Cl a ss ic  ( THH -A)  

The heate r that is  a design  fea ture!  

Содержание Classic THH-A Series

Страница 1: ...Product Installation Manual HEATSTRIP Classic THH A The heater that is a design feature ...

Страница 2: ...y Each has a different temperature output making them ideal for different applications Below is a list of some common applications to assist with the selection of the most effective and efficient series HEATSTRIP Classic THH A models is a premium high temperature heater and is primarily used for outdoor rooms where there is 1 2 3 or 4 enclosed sides with an mounting height of 2 1m to 2 7m HEATSTRI...

Страница 3: ...e operation Australian made Designed engineered and assembled in Australia the HEATSTRIP is fully backed by a 24 month residential warranty and 12 month commercial warranty Stylish design The Heater that is a Design Feature The attractive HEATSTRIP comes with a standard black face and anodised alloy rear casing Easy to use The standard HEATSTRIP is controller by a simple on off operation either wh...

Страница 4: ...when in use blending elegantly into your décor Ceiling wall and umbrella mounting options ensure that your valuable floor and table space is not wasted Efficient cost effective electric heating The innovative design of the HEATSTRIP enables comfortable and even heat dispersion from the heater surface with minimal operating costs Design flexibility Four HEATSTRIP models are available ensuring the h...

Страница 5: ...chart above POWER 230 240 Volts Nominal at 50 60 Hertz Single Phase CONNECTION 3 Core Cable 2 5mm2 APPROVALS AUSTRALIA NZ MOUNTING HEIGHT MINIMUM RECOMMENDED MAXIMUM 2 1 m 2 3 m to 2 5 m 2 7 m in a fully enclosed outdoor area For higher ceiling heights units can be lowered using optional bracket kits or refer to the Heatstrip Max range MOUNTING OPTIONS Suitable for ceiling wall beam fixed umbrella...

Страница 6: ...x 165 x 115 5 NONE NO THH2400AUL NORTH AMERICA 240 2400 10 924 x 165 x 115 7 NONE NO THH3200AUL NORTH AMERICA 240 3200 13 3 924 x 165 x 115 9 NONE NO THH2400AUM NORTH AMERICA 208 2400 10 924 x 165 x 115 7 NONE NO THH3200AUM NORTH AMERICA 208 3200 13 3 924 x 165 x 115 9 NONE NO THH1300AJP JAPAN 100 1300 6 3 924 x 165 x 48 5 1000 YES 100V THH1400AJP JAPAN 200 1400 7 5 924 x 165 x 48 5 1000 YES 200V ...

Страница 7: ...r 2 Electricity rate of 20 0 cents kWh 3 All calculations are excluding GST 1 5kW x 0 20 cents 0 30 or 30 cents per hour 1 8kW x 0 20 cents 0 36 or 36 cents per hour 2 4kW x 0 20 cents 0 48 or 48 cents per hour 3 2kW x 0 20 cents 0 64 or 64 cents per hour Calculations of yearly running cost are based on 180 hours usage 180 hours x 2 78 500 40 yearly running cost for outdoor gas heater 180 hours x ...

Страница 8: ...BBQ s lounges assembly lines or in door workstations Often it is more practical and efficient to spot heat high use areas Spot heating will reduce both the initial capital cost as well as the ongoing running costs Spot heating will allow the area to be zoned meaning only the areas that are being used are heated such as tables in a restaurant or outdoor alfresco area Option 1 and 2 show a compariso...

Страница 9: ... recommended mounting heights and if possible positioning the heater directly above the area to be heated Note that the temperature is the same for all 4 models regardless of the wattage However as the size increases and the length of the unit increases the radiant footprint will be longer The below diagrams show the approximate heating area for each model based on both an indoor and outdoor enclo...

Страница 10: ...or spot heating a minimum heating capacity of 400W m2 is recommended The table below outlines the coverage of each HEATSTRIP Classic model based on 3 different scenarios with direct overhead mounting For example for an outdoor area that is protected from prevailing winds by walls café blinds etc Model THH 1500A will cover 3m2 and Model THH2400A will cover 4 8m2 For angled wall mounting application...

Страница 11: ... a table or similar area The diagrams below provide an easy selection guide for the approximate model and quantity of heaters required to heat common residential table settings Selections are based on HEATSTRIP Classic being mounted at 2 4m from the floor in a fully enclosed undercover outdoor area ...

Страница 12: ...sories to reduce the height of the heater to 2 3m 2 5 m This will increase the effectiveness of your HEATSTRIP Refer to the Mounting Accessory section for more information Electrical connections GPO s should not be located at the back of the heater They should be located outside the physical footprint of the units to minimize heat build up behind the units If the heater is to be mounted on an incl...

Страница 13: ...T FAN OR SPRINKLER MUST NOT BE BELOW THE HEATER CEILING FLOOR Wall SURFACE BELOW HEATER SURFACE BELOW HEATER 1500 Min 1000 Min 2100 Min CEILING FLOOR Wall 60 Min 60 Min LIGHT FAN OR SPRINKLER MUST NOT BE BELOW THE HEATER Installation location the below diagrams below provide the minimum recommended clearances Angled Ceiling Installation Ceiling Installation Angled Wall Installation ...

Страница 14: ...e of mounting options available refer to diagrams below The HEATSTRIP Classic can be mounted directly to the ceiling angled downwards on a wall fitted flush with the ceiling suspended on chains or poles attached to beams or poles mounted end to end or 2 units side by side together Refer to the following pages for more detailed information on each mounting option ...

Страница 15: ...These adjustable brackets allow direct ceiling or wall mount and come with preset angle options of parallel 22 5 and 45 PART No PACKAGED DIMENSIONS mm WEIGHT kg MATERIALS ZBRAK 103 125 x 150 x 40 0 2 ALLOY MODEL X MINIMUM DISTANCE mm THH1500A 550 THH1800A 710 THH2400A 1000 THH3200A 1470 CEILING WALL X ...

Страница 16: ...for all HEATSTRIP Classic models and are supplied as a one piece unit suitable for mounting individual heaters Flush mounting can be used with plaster or timber lined ceiling materials An ideal mounting height is 2 3m 2 5m with a maximum ceiling height of 2 7m in an outdoor enclosed environment Maximum mounting heights should be strictly followed otherwise the performance of the units may be reduc...

Страница 17: ...e beam pole can be placed directly on top of the mounting bracket No clearance is required from the top bracket to the bottom of beam pole PART No PACKAGED DIMENSIONS mm WEIGHT kg MATERIALS THHAC 001 150 x 150 x 50 0 5 316 SS 70mm Maximum 42mm MAX 5mm HARDWARE The optional Pole Beam mounting bracket kit can be used to mount HEATSTRIP Classic onto wooden beams rafters poles umbrellas struts etc ...

Страница 18: ...nits of HEATSTRIP Classic to be mounted side by side either in parallel or angled as per the diagram on the right This is ideal for applications when a wider heat coverage is required or when there are mounting restrictions or limitations The Twin Mount bracket can also be used with the Extension Mount bracket and Pole Kit to lower the units from a high ceiling ...

Страница 19: ...d aesthetic appeal This is ideal for applications such as long rows of tables and assembly lines where a constant heat coverage is required The bracket allows for a 50mm gap between units and an opening for the power connection As per the dia gram below units should be mounted with the power leads together The end to end bracket can be used with either the standard ceiling wall mount bracket or th...

Страница 20: ... for lowering the HEATSTRIP Classic from high ceilings The bracket is designed to be used with chains or wires There can be multiple chain wire arrangement options as per the diagram below Note chains or cable are not supplied with heaters or brackets PART No PACKAGED DIMENSIONS mm WEIGHT kg MATERIALS SUITABLE FOR MODELS THHAC 002 300 x 150 x 50 1 316 SS THH1 500A THH 1800A THHAC 003 1200 x 120 x ...

Страница 21: ... x 150 x 50 3 316 SS Kit includes 2x1200mm extension pole screws The Extension Mount bracket allows HEATSTRIP Classic units to be lowered from high ceilings using rigid connections The brackets are designed to be used with 25mm x 25mm x 1mm tube SHS and can be sup plied as brackets only for customising the length of the drop on site or supplied as a complete kit with brack ets pre cut poles and co...

Страница 22: ...nected to the horizontal umbrellas struts using the Pole Beam mounting kit THHAC 001 Quick reference guide for spot heating common permanent umbrella structure 9m2 umbrella area 4 x THH 1500A 12 m2 umbrella area 6 x THH 1500A or 4 x THH 1800A 16 m2 umbrella area 8 x THH 1500A or 6 x THH 1800A This is a guide only For more detailed information please contact the umbrel la manufacturer your nearest ...

Страница 23: ...eater needs to be installed as per the installation instructions paying special attention to the minimum clearances The heater needs to be mounted on a rigid bracket or fixing The heater must not be mounted immediately below or in front of a socket outlet In case of a heater fault or damaged supply lead the appliance should be returned to the point of purchase for return to Thermofilm for repair M...

Страница 24: ...ces the likelihood of heaters being inadvertently left turned on Depending on the ambient temperature there may be a requirement to adjust the heat output of the heater The controller has 3 settings they are High Medium and Low The controller allows a combination of the multiple timer 1 2 4 hour and heat outputs High Medium Low The controller comes with a remote control unit which provides conveni...

Страница 25: ...h power load setting The vents must remain clear at all times never block or cover the vents An ideal controller installation will provide significant space around the back of the controller Installing into restricted spaces such as brick walls may result in overheating if adequate ventilation is not provided ACTIVE EARTH NEUTRAL L N 220 240V 50Hz Supply GANG BOX Load 16A Max ...

Страница 26: ...the maximum current rating of 16A must not be ex ceeded For direct wiring to the controller the maximum is generally one heater unit unless the combined maximum cur rent is less than 16A For example 2x THH1800A can be connected directly to the controller Below are example circuits indicating potential installation configurations Always check with your electrician and ensure all wiring is in accord...

Страница 27: ...n for more detail Below is an example circuit indicating one potential installation configuration Always check with your electrician and ensure all wiring is in accordance with local regulations Note to electrician The controller modulates the heat output using a timed on timed off function The controller does not modulate the voltage output A relay is therefore suitable for this application ...

Страница 28: ...orized representative of Thermofilm Thermofilm does not participate in any site related costs or labour expenses incidental to replacement of parts repairing removing installing servicing transportation or handling of parts to complete products and assumes no liability on parts repaired or replaced without written authorisation Thermofilm shall not be liable for any default or delay in performance...

Отзывы: