background image

 

CONTENTS 

If you experience any difficulty with the installation or operation of your new 

 water heater, then please refer to the “What to do if things go wrong” section 

 in this manual before contacting us. 

 

INTRODUCTION 

 

THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE AND 

PERSONS WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES,  

OR LACK OF EXPERIENCE AND KNOWLEDGE IF THEY HAVE BEEN GIVEN SUPERVISION 

 OR INSTRUCTION CONCERNING USE OF THE APPLIANCE IN A SAFE WAY  

AND UNDERSTAND THE HAZARDS INVOLVED. 

 

CHILDREN SHALL NOT PLAY WITH THE APPLIANCE. 

 

CLEANING AND USER MAINTENANCE SHALL NOT BE MADE BY CHILDREN. 

 

 

 
 

 

Thank you for purchasing a quality 

Heatstore Multiflow

  manufactured in England. 

To enjoy your new unit at its best, please take time to read this manual thoroughly to 
familiarise yourself with all instructions, BEFORE beginning installation. 
 
 

 
 

 

 

 

Your 

Multiflow

 has been designed for convenience, economy and safety of use, provided that it is 

installed, used and maintained in good working order and in accordance with our instructions and 

recommendations. 

 

 

All wiring and installation must be supervised by a suitably qualified person. 

 

 

THIS APPLIANCE MUST BE EARTHED. 

 

 

The installation must be in accordance with the current edition of BS.7671 (

the “IEE Wiring

 

Regulations”)

 and “Part P” of the 

“Building Regulations”

 in force at the time of installation. 

Installations outside England and Wales must also conform to any local regulations in effect. 

 

 

This appliance is intended to be permanently connected to the fixed electrical wiring of the mains 

supply with its own dedicated supply. 

 

 

Ensure that the mains water supply meets the requirements listed.  

 

 

This appliance must 

NOT

 be fitted where it may be subjected to freezing conditions                       

DO NOT

 switch the appliance on if you suspect it of being frozen. Wait until it has thawed out. 

 

 

The unit MUST NOT be mounted upside down (diagram 1b).   

  

 

The unit MUST NOT be fitted to any type of THERMOSTATIC mixer valve or tap.  

 

 

If a non-return valve is fitted in the Inlet feed to the unit, then the installation should also include 

a 3.5 BAR Pressure Reducing Valve and a 6 BAR Pressure Relief (Expansion) Valve. 

 

 

Isolate the mains electrical and water supply before removing appliance front cover. 

 

 
 
 

 
 
 

 

Section 
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .    

Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   

How to install your 

Multiflow

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   

Commissioning your 

Multiflow

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   

How to use your 

Multiflow

   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .    

What to do if things go wrong (1) Self Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Heatstore After Sales Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Additional Accessories and Common Spare Parts  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   

What to do if things go wrong (2) Professional Service . . . . . . . . . . . . . . . . . . . . . . . . . .  

How your 

Multiflow

 Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

Guarantee and Contact Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Page 

10 

11 

12 

IMPORTANT SAFETY INFORMATION 

Содержание Multiflow 10.8kW

Страница 1: ...h the user after installation and demonstration It should be kept in a safe place as you may need to refer to it for general instructions or future maintenance HEATSTORE MULTIFLOW UNVENTED INSTANTANEOUS WATER HEATER Installation and User Guide ...

Страница 2: ... the current edition of BS 7671 the IEE Wiring Regulations and Part P of the Building Regulations in force at the time of installation Installations outside England and Wales must also conform to any local regulations in effect This appliance is intended to be permanently connected to the fixed electrical wiring of the mains supply with its own dedicated supply Ensure that the mains water supply m...

Страница 3: ...namic Water Pressure Basin Shower Minimum Maximum Minimum Maximum Up to 9 5kW 10 psi 0 7 bar 69 kPa 150 psi 10 3 bar 1035 kPa 15 psi 1 1 bar 103 kPa 150 psi 10 3 bar 1035 kPa Up to 10 8kW 15 psi 1 1 bar 103 kPa 150 psi 10 3 bar 1035 kPa 20 psi 1 4 bar 138 kPa 150 psi 10 3 bar 1035 kPa Up to 12 0kW 20 psi 1 4 bar 138 kPa 150 psi 10 3 bar 1035 kPa 25 psi 1 8 bar 172 kPa 150 psi 10 3 bar 1035 kPa FIX...

Страница 4: ... the backplate diagram 3 Feed the cable through the grommet before you fix the unit to the wall Fixing to the wall Undo the retaining nuts and take the front cover off the unit Hold the backplate in position against the wall whilst you mark the four fixing holes Drill the holes and fix the unit to the wall using the screws supplied Plumbing the unit WARNING IF A NON RETURN VALVE IS FITTED IN THE I...

Страница 5: ...Connecting the unit to the pipes The inlet and outlet are clearly marked on the unit They each have a Ø15mm straight shank connections The unit comes with a service valve diagram 5 which should be fitted on the inlet of the unit The valve can be used to turn off the water supply to the unit if it needs servicing or to reduce the main supply flow if it is too high Fitting the attachments If the uni...

Страница 6: ... 6 point X to X to enable 10mm and 16mm to be correctly installed No cutting is required for 6mm cable In all cases the outer sheath of the cable MUST project through the grommet diagram 6 if side entry is used This will prevent water getting into the unit Strip back the insulation on the LIVE brown or red and NEUTRAL blue or black mains wires about 8mm Strip back any insulation on the EARTH green...

Страница 7: ...on light goes out then turn it back until the neon just comes on check the water temperature at the handset and if necessary turn the cold tap on and adjust to get the desired shower temperature WARNING YOU MUST REGULARLY INSPECT THE SHOWER HOSE FOR WEAR AND DAMAGE REPLACE IF NECESSARY OR EVERY TWO YEARS WITH OUR APPROVED PART WARNING IN ORDER TO MAINTAIN THE PERFORMANCE OF YOUR SHOWER YOU MUST DE...

Страница 8: ...shed do not switch off the power if you are going to use the unit again shortly Shower Check that the power is switched on at the mains local isolator switch Turn on the hot or flow tap FULLY diagram 9 If the unit has been used recently run the water through for a few seconds to let the temperature settle down we advise you DO NOT enter the water flow during this time WARNING YOU MAY INITIALLY GET...

Страница 9: ... the thermal cut out is operating A second outlet has been turned on Increase the supply water flow Make sure that the service valve is correctly adjusted Do not use the basin whilst using the shower Shower spray pattern deteriorates The shower handset is clogged Clean the handset using a descaling solution if required see page 9 We offer a technical advisory service on the telephone to installers...

Страница 10: ...n supply to the INLET marked in blue Use a pump to boost the supply from a storage tank Reset it by opening the unit and pushing the button on the cut out diagram 11 Before you do this you must remove the cause of the problem Contact Heatstore Water too cold neon light on The power select screw is set to LO One element is not working The Power Supply Voltage has dropped Change the power select scr...

Страница 11: ...s means that with the 12 0kW unit you can shower at 39 C with a flow rate of 5 litres minute in the middle of winter The unit includes a dual thermal cut out diagram 11 which is attached to the heat exchanger tube It will switch off the heater elements if the water flow is reduced too much and the temperature goes above a set limit The first stage cut out is cyclic and will automatically reset as ...

Страница 12: ... NOT cover damage or defects arising from poor or incorrect installation improper use or lack of maintenance including the build up of limescale The unit MUST NOT be fitted to any type of thermostatic mixer valve or tap The unit MUST NOT be fitted to a bath or kitchen sink other than for hand washing purposes It is the responsibility of the installer to check that the installation parameters meet ...