background image

18

Installation Instructions and Owner’s Manual

Unvented Natural Gas Vent Free Room Heaters

PARTS LIST AND DIAGRAM

MODEL: HSSVFBF20NGBT

ITEM

P/N

PART DESCRIPTION

QTY

1

80122

Wire Guard

1

2

80096

Front Panel (Beige)

1

80205

Front Panel (White)

1

3

80087

Reflector

1

4

80088

Front Heat Shield

1

5

80093

Glass

1

6

80091

Glass Bracket

1

7

80107

Regulator

1

8

NA

Regulator Connection

1

9

80055

Regulator Mounting Bracket

1

10

80057

ODS Pilot Assembly w/ Thermo

-

couple

1

11

80085

Burner Assembly

1

12

80009-07

Orifice

1

13

80073

Orifice Adapter

1

ITEM

P/N

PART DESCRIPTION

QTY

14

70640

Thermostat Valve

1

15

80014

Igniter Wire

1

16

80019

Igniter Module

1

17

80011

Igniter Module Mounting Bracket

1

18

80010

Thermostat Valve Mounting 

Bracket

1

19

80058

Floor Mounting Feet (Beige)

1

80214

Floor Mounting Feet (White)

1

20

80097

Back Panel (Beige)

1

80179

Back Panel (White)

1

21

80037

Wall Mounting Bracket

1

22

80013

High Limit Switch (Fan)*

1

23

F299201

Fan Assembly*

1

24

80049

Fan Switch*

1

**

70342

Hardware Kit (not shown)

1

*If Equipped

WARNING:

 Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with 

this heater may result in property damage or personal injury.

1

2

3

4

5

7

8

9

10

12

13

11

14

18

19

20

21

17

16

15

6

23

22

24

Содержание HSSVFBF20NGBT

Страница 1: ...llation and service must be performed by a qualified installer service agency or the gas supplier This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisi...

Страница 2: ...lts should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition Young children should be carefully supervised when they are in the same room wi...

Страница 3: ...ximum 14 Inches of Water 14 Inches of Water 14 Inches of Water 14 Inches of Water Inlet Gas Pressure Minimum 7 Inches of Water 7 Inches of Water 7 Inches of Water 7 Inches of Water Electrical Rating B...

Страница 4: ...ose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kW of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is no...

Страница 5: ...space because the actual Btu hr used is more than the maximum Btu hr the space can support You must provide additional fresh air Your options are as follows A Rework worksheet and the space of an adj...

Страница 6: ...ble alternative to test gauge connection Purchase a CSA AGA certified equipment shutoff valve from your dealer LOCATING HEATER This heater is designed to be mounted on the wall The heater can also be...

Страница 7: ...wall stud mounting locate one end of the mounting bracket over a wall stud WARNING Maintain minimum clearances shown in fig ure 7 If you can provide greater clearances from the floor and joining wall...

Страница 8: ...ING AWAY FROM WALL Installing Support Feet See figure 11 1 Lay heater onto table on its back with bottom edge overhanging table edge 2 Securely attach feet to bottom of heater using 2 self tapping scr...

Страница 9: ...ppliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 5 kPa 2 Cap off open en...

Страница 10: ...ettle on the floor WHAT TO DO IF YOU SMELL GAS Shut off gas supply Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call you gas s...

Страница 11: ...HEATER 1 Turn off equipment shutoff valve 2 Turn control knob clockwise to the OFF position SHUTTING OFF BURNER ONLY PILOT STAYS LIT 1 Turn control knob clockwise to the PILOT IGN position THERMOSTAT...

Страница 12: ...lean CLEANING BURNER PILOT AIR HOLE INLET We recommend that you clean the unit every 2 500 hours of operation or every three months We also recommend that you keep the burner tube and pilot assembly c...

Страница 13: ...13 Installation Instructions and Owner s Manual Unvented Natural Gas Vent Free Room Heaters PAGE LEFT INTENTIONALLY BLANK...

Страница 14: ...d by any metal or tubing Keep igniter cable dry Broken igniter cable Replace igniter cable Bad Piezo igniter Replace control valve Low Battery Replace battery When igniter button is pressed in there i...

Страница 15: ...irty or partially clogged burner orifice Clean burner orifice see Cleaning and Maintenance on page 1 1 or replace burner orifice White powder residue forming within burner box or on adjacent walls or...

Страница 16: ...Valve 1 12 80019 Igniter Module 1 ITEM P N PART DESCRIPTION QTY 13 80010 Thermostat Valve Mounting Bracket 1 14 8001 1 Igniter Module Mounting Bracket 1 15 80058 Floor Mounting Feet Beige 1 80214 Floo...

Страница 17: ...Valve 1 12 80019 Igniter Module 1 ITEM P N PART DESCRIPTION QTY 13 80010 Thermostat Valve Mounting Bracket 1 14 8001 1 Igniter Module Mounting Bracket 1 15 80058 Floor Mounting Feet Beige 1 80214 Floo...

Страница 18: ...1 ITEM P N PART DESCRIPTION QTY 14 70640 Thermostat Valve 1 15 80014 Igniter Wire 1 16 80019 Igniter Module 1 17 8001 1 Igniter Module Mounting Bracket 1 18 80010 Thermostat Valve Mounting Bracket 1...

Страница 19: ...1 ITEM P N PART DESCRIPTION QTY 14 70640 Thermostat Valve 1 15 80014 Igniter Wire 1 16 80019 Igniter Module 1 17 8001 1 Igniter Module Mounting Bracket 1 18 80010 Thermostat Valve Mounting Bracket 1...

Страница 20: ...MITED WARRANTY Enerco Group Inc EGI warrants Heatstar Vent free heaters to be free from defects in material and workmanship for a period of five years from the date of manufacture During the first two...

Отзывы: