Operating Instructions and OwnerÊs Manual
11
Forced-Air Dual-Fuel NOMAD Construction Heater
Symptom
Troubleshooting
Blower does not come on
1. Make sure the switch is either in the on or fan only posi-
tion
2. Verify the extension cord being used is not too long
3. Check power source is 110v
4. Verify the setting on the thermostat is higher than the
temperature in the space to be heated
Blower runs but the burner does not ignite
1. Make sure the switch is in the on position not in the fan
only position
2. Verify that the fuel connected to the unit is turned on and
flowing. It may take a few cycles to get all the air out of
the lines.
3. Make sure the rate and fuel switch are in the desired posi-
tion for the fuel you are using and the setting (high or
low) that you desire.
Unit producing little heat or no heat.
1. Make sure the switch is in the on position not the fan only
position
2. Make sure the rate and fuel switch are in the desired posi-
tion for the fuel you are using and the setting (high or
low) that you desire.
3. Verify that the fuel pressure being supplied to the heater is
adequate. Refer to the specification table in this manual for
required pressures.
4. Make sure the factory supplied hose and regulator are be-
ing used.
Heater will not shut down
1. Verify the switch is in the off position not on or fan only.
2. Check current setting on the thermostat. Is it set to a tem-
perature higher than the space being heated?
3. Heater will only cycle on and off when optional thermostat
is installed.
Unit will not turn on with thermostat installed
1. Verify that the thermostat is installed correctly. Heater will
only cycle on and off when the optional thermostat is
installed.
2. Verify the setting on the thermostat is higher than the
temperature in the space to be heated
3. Check that the power switch is in the "on" position. The
thermostat will only cycle on and off if the power switch is
in the on position
Unit will not turn off with thermostat installed.
1. Verify the setting of the thermostat is lower than the tem-
perature in the space being heated.
2. Verify that the thermostat is installed correctly, the unit
may just be on the on position.
3. Heater may be undersized or for the space being heated.
Red HLS fault light is on
1. Verify that the path of heat is not obstructed.
2. Check for blockage in the duct and at the end diffuser
3. Check the fuel and rate selections are accurate. If the
wrong fuel is selected the unit will over heat.
FOR FURTHER ASSISTANCE
If after you have reviewed the trouble shooting in this
manual and you still require assistance please use any of
the following methods to contact our technical service
department
.
We will do our absolute best to resolve any
issues or problems that arise. Most problems can be solved in
just a few minutes.
HOURS ARE: Monday- Friday 8:00am until 5:00pm
CALL: 866-447-2194
FAX: 800-321-0552
VISIT: HEATSTARBYENERCO.COM
INQUIRIES IN CANADA ONLY
PLEASE CALL: 877-477-3353
VISIT IPSPOWER.COM
Содержание F109100
Страница 14: ...14 Forced Air Dual Fuel NOMAD Construction Heater Operating Instructions and Owner s Manual NOTES...
Страница 16: ...16 Forced Air Dual Fuel NOMAD Construction Heater Operating Instructions and Owner s Manual NOTES...
Страница 18: ...18 Forced Air Dual Fuel NOMAD Construction Heater Operating Instructions and Owner s Manual NOTES...
Страница 34: ...34 Forced Air Dual Fuel NOMAD Construction Heater Operating Instructions and Owner s Manual REMARQUES...
Страница 36: ...36 Forced Air Dual Fuel NOMAD Construction Heater Operating Instructions and Owner s Manual REMARQUES...
Страница 38: ...38 Forced Air Dual Fuel NOMAD Construction Heater Operating Instructions and Owner s Manual REMARQUES...
Страница 54: ...54 Forced Air Dual Fuel NOMAD Construction Heater Operating Instructions and Owner s Manual NOTAS...
Страница 56: ...56 Forced Air Dual Fuel NOMAD Construction Heater Operating Instructions and Owner s Manual NOTAS...
Страница 58: ...58 Forced Air Dual Fuel NOMAD Construction Heater Operating Instructions and Owner s Manual NOTAS...