10
Forced-Air Dual-Fuel NOMAD Construction Heater
Operating Instructions and OwnerÊs Manual
PROPANE TANK SIZE SELECTION
Below are a few quick points of reference for when you
need to select propane cylinders for your applications.
There are two major points to consider. What is the
temperature outside? & What are the BTU requirements
of the heater I will be using. While 20lb, 40lb and 100lb
tanks are the most common tank sizes, there are various
other options available. Contact you propane supplier for
details.
LBS OF LP IN THE CYLINDER
MAXIMUM CONTINUOUS BTU OUTPUT PER HOUR
@ VARIOUS TEMPERATURES
0
°F (-18°C)
20
°F(-7°C)
40
°F (4°C)
200 (2 x 100's)
226,000
334,000
428,000
100
113,000
167,000
214,000
80 (2 x 40's)
94,000
137,000
180,000
40
55,000
79,000
105,000
20
36,000
51,000
69,000
PROPANE TANK SELECTION @ 20°F (-7°C)
HIGH SETTING
LOW SETTING
HS115TC
110,833 BTU/HR
80,612 BTU/HR
2 X 40LB TANKS
1 X 40LB TANK
HS190TC
190,200 BTU/HR
127,100 BTU/HR
2 X 100LB TANKS
2 X 40LB TANKS
HS250TC
248,625 BTU/HR
181,119 BTU/HR
2 X 100LB TANKS
2 X 100LB TANKS
EXAMPLE TANK SELECTION
20LBS
40LBS
100LBS
18”
29”
48”
12.5”
12.5”
14.5”
• The flame is contained within the heater.
• The flame is essentially blue with perhaps some yel-
low tipping.
• There is no strong disagreeable odor, eye burning or
other physical discomfort.
• There is no smoke or soot internal or external to the
heater.
• There are no unplanned or unexplained shut downs
of the heater.
• The parts lists and wiring diagram show the heater
as it was constructed. Do not use a heater which is
different from that shown. In this regard, use only
the hose, regulator and cylinder connection fitting
(called a POL fitting) supplied with the heater.
For this heater, the regulator must be set as shown in
„SPECIFICATIONS‰. If there is any uncertainty about the
regulator setting, have it checked. A heater which is not
working right must be repaired, but only by a trained,
experienced service person. The heater is equipped with
a 1 year Limited Warranty, for full warranty information
please read page 20. Please include a brief statement
indicating date, place of purchase, the nature of the
problem and proof of purchase for warranty inquiries.
Out-of-warrranty products can be repaired with a charge
for parts and labor. Contact customer service for a list of
certified repair centers near you.
Содержание F109100
Страница 14: ...14 Forced Air Dual Fuel NOMAD Construction Heater Operating Instructions and Owner s Manual NOTES...
Страница 16: ...16 Forced Air Dual Fuel NOMAD Construction Heater Operating Instructions and Owner s Manual NOTES...
Страница 18: ...18 Forced Air Dual Fuel NOMAD Construction Heater Operating Instructions and Owner s Manual NOTES...
Страница 34: ...34 Forced Air Dual Fuel NOMAD Construction Heater Operating Instructions and Owner s Manual REMARQUES...
Страница 36: ...36 Forced Air Dual Fuel NOMAD Construction Heater Operating Instructions and Owner s Manual REMARQUES...
Страница 38: ...38 Forced Air Dual Fuel NOMAD Construction Heater Operating Instructions and Owner s Manual REMARQUES...
Страница 54: ...54 Forced Air Dual Fuel NOMAD Construction Heater Operating Instructions and Owner s Manual NOTAS...
Страница 56: ...56 Forced Air Dual Fuel NOMAD Construction Heater Operating Instructions and Owner s Manual NOTAS...
Страница 58: ...58 Forced Air Dual Fuel NOMAD Construction Heater Operating Instructions and Owner s Manual NOTAS...