Heatmiser Touch Carbon Скачать руководство пользователя страница 1

Model:

Touch Carbon

Содержание Touch Carbon

Страница 1: ...Model Touch Carbon...

Страница 2: ...1 Touch Series Model Touch Carbon...

Страница 3: ...ermostat LCD Display Power On OFF Setting the Time Date Temperature Display Pairing Accessories View Accessories Removing Accessories Edit Comfort Levels Temperature Control Temperature Hold Advance 8...

Страница 4: ...es you want the heating to be on and what temperature it should reach while it is on It will allow you to select different temperatures in your home at different times of the day and days of the week...

Страница 5: ...with the temperature You won t have to adjust the thermostat further Any adjustment above this setting will waste energy and cost you more money You are able to temporarily adjust the heating program...

Страница 6: ...the wall prior to installation Step 1 Using a small screwdriver slightly loosen the screw from the bottom face of the thermostat You can then carefully separate the front half from the back plate Ste...

Страница 7: ...6 Model Touch Carbon 1 2 3 4...

Страница 8: ...The Touch V2 will factory reset then provide 2 selectable mode options Use the Left Right keys to scroll between modes Mode 1 Thermostat Mode 2 Time Clock Note the selected option will flash Press DON...

Страница 9: ...8 Model Touch Carbon Mode 1 Thermostat...

Страница 10: ...9 5 6 1 2 3 4 7 8 9 12 11 10 13 15 14 18 19 17 21 20 22 23 16 Touch Series...

Страница 11: ...Symbol Displayed when the floor probe has reached the floor temperature limit configured in the setup menu 12 Floor Room Temp Set Indicates the displayed sensor mode and when changes are being made t...

Страница 12: ...n the Flame Icon is absent there is no requirement for heating to achieve the set temperature but the Touch Carbon remains active To turn the Thermostat off completely press and hold the key for appro...

Страница 13: ...a dark room To set the clock follow these steps Press and hold the key for 3 seconds At this point the screen will go blank showing only CLOCK and SETUP Tap the CLOCK key The Hour digits will now fla...

Страница 14: ...r or both The display will clearly indicate which sensor is being used by showing either ROOM TEMP or FLOOR TEMP to the left the actual value When the Touch Carbon is set to use both the air the floor...

Страница 15: ...at Averaging will also be calculated between multiple Air Sensors Window DoorWireless Contact Sensor If any one of the Window Door contacts is broken theTouch Carbon thermostat will be alerted and wil...

Страница 16: ...an be added On the Air Sensor Window Door Contact press and hold the pairing button for 5 seconds The LED will glow red to indicate pairing status If the sensor has successfully paired the LED will go...

Страница 17: ...creen then press NEXT Use the Up Down arrow keys to scroll through the list of attached accessories A Wireless Air Sensor will show the current temperature The Window Door Contact will display current...

Страница 18: ...nsor Switch LED indicator will flash 3 times to confirm reset At this point the Sensor Contact will notify the Touch Carbon that it has left and will automatically be removed from the Accessory Menu O...

Страница 19: ...21 C Return 22 00 16 C Sleep Unused levels must be set to so that theTouch Carbon will skip these and continue on to the next programmed time ForWeekday Weekendprogramming thefourcomfortlevelsarethes...

Страница 20: ...ss the Right arrow key LEAVE will now flash and the current settings will be displayed Repeat these steps above to set all comfort levels For any unused periods set time to Press DONE to confirm and s...

Страница 21: ...ither key you will see the words SETTEMP and the desired temperature value Press DONE to confirm temperature setting and return to the main display Note Thisnewtemperatureoverrideismaintainedonlyuntil...

Страница 22: ...sired Hold time Minutes Use the Up Down keys to set the desired Hold temperature Press DONE to confirm selection You will see the HOLD LEFT indication is displayed on screen The time will countdown th...

Страница 23: ...lowed by DONE to confirm Advanced Until time Level Advanced Until Press the Advance key once then press CANCEL This feature allows the next Comfort Level setting to be brought forward and become activ...

Страница 24: ...y is pressed In this mode the Touch Carbon will display the frost icon and will only turn the heating ON should the room temperature drop below the set frost temperature If the heating is turned ON wh...

Страница 25: ...Use the Up Down keys to set the next two digits Press DONE The display will return to the main screen and display the keypad lock indicator Note The keypad lock indicator is only displayed when the lo...

Страница 26: ...s temperature for the duration of the holiday and will then automatically return to the program mode on your return To set a Holiday Press the HOLIDAY key once Enter the return time hours by using the...

Страница 27: ...at 18 C and off at 20 C Condition Whilst Optimum Start is in effect the Switching Differential shall default to 1 C F Output Delay To prevent rapid switching an output delay can be entered This can be...

Страница 28: ...feature and is for information only Programming Mode The following program modes are available Non Programmable Basic up down override temperature control 5 2 Day Programming 4 levels for the weekday...

Страница 29: ...1 0 C Default 02 2 0 C 03 3 0 C 00 15 Minutes 00 Default 00 10 C 00 Default 00 BuiltinSensorwithoptionalwirelessRemoteAir Default 01 WirelessRemoteAirOnly 02 FloorSensorOnly 03 Builtin FloorSensor opt...

Страница 30: ...ay will go blank showing only Setup and Clock Press the SETUP key once then press NEXT Use the Up Down keys at the top to scroll through features Use the Up Down keys in the centre to change feature s...

Страница 31: ...repeat every hour Failsafe will continue until the thermostat re establishes connection to the remote sensor Modbus interface allows the thermostat to be controlled via home automation or a building m...

Страница 32: ...ress the DONE key to confirm the change and the display will go blank Press the key once to turn the thermostat ON E0 The internal sensor has developed a fault E1 The remote FLOOR probe has not been c...

Страница 33: ...itch Live Output NEUTRAL MODBUS INTERFACE Model Touch Carbon LIVE 230V SUPPLY IN SWITCHED LIVE TO BOILER 230VAC RT1 A2 A1 N L B This product must only be installed by a qualified electrician and compl...

Страница 34: ...ARE NORMALLY THE ROOM THERMOSTAT CONNECTIONS MODBUS INTERFACE Model Touch Carbon LIVE 230V SUPPLY IN VOLT FREE TO BOILER 230VAC RT1 A2 A1 N L A This product must only be installed by a qualified elec...

Страница 35: ...nstalled by a qualified electrician and comply with local installation regulations MODBUS INTERFACE Model Touch Carbon 230VAC RT1 A2 A1 N L A Floor Sensor Wiring Diagram Touch Carbon to Valve LS LR AR...

Страница 36: ...Live to UH8 This product must only be installed by a qualified electrician and comply with local installation regulations MODBUS INTERFACE Model Touch Carbon 230VAC RT1 A2 A1 N L A FLOOR PROBE L S E N...

Страница 37: ...ch Carbon Mode 2 Time Clock Time clock can be used to control various devices in and around your home e g HotWater Towel Rails or even Lighting Refer to the manufacturers instructions for wiring to th...

Страница 38: ...37 3 4 1 2 5 6 7 9 10 11 12 8 Touch Series...

Страница 39: ...n 5 Clock Time displayed in 24 hour format 6 Set Indicated when changes are being made to the current set point 7 Program Indicator Displayed during programming to show which level is being altered 8...

Страница 40: ...ash and the ON time will be displayed Use the Up Down key at the top to set the Hours Minutes Press Next The OFF time will now be displayed Use the Up Down key at the top to set the Hours Minutes Pres...

Страница 41: ...ing time level setting to be brought forward and become active before its pre programmed time Note Multiple advances aren t allowed To enable Advance Press the ADVANCE key once The ADVANCED UNTIL time...

Страница 42: ...on You will see the HOLD LEFT indication is displayed on screen The time will countdown the set duration and then revert to the normal program To cancel Timer Override Press HOLD then press CANCEL Cou...

Страница 43: ...r from Standard Time during the summer months and back again in autumn in order to make better use of natural daylight Communications ID To interface with building management systems using the standar...

Страница 44: ...ly Setup and Clock Press the SETUP key once then press NEXT Use the Up Down keys at the top to scroll through features Use the Up Down keys in the centre to change feature setting When all required ch...

Страница 45: ...crew driver or fingertip to push back the brass retaining bracket This will automatically release the battery Insert the new battery positive side up by locating one end underneath the holding clips t...

Страница 46: ...45 Notes 45 Touch Series...

Страница 47: ...46 Notes Model Touch Carbon...

Страница 48: ...1254 669090 Or view technical specifications directly on our website www heatmiser com Twitter heatmiseruk Facebook facebook com thermostats Rev 1 0 Heatmiser UK Ltd 1 5 Hurstwood Court Mercer Way Sh...