NOTE: The SBF-100 and SBF-200 Circulator is to be used only with V-90, V-100, HMU
and HMUT series gas logs!
INSTALLATION:
1.
Gas supply must be turned off before installing the SBF-Series Circulator.
2.
If the gas log set has been installed before the circulator is installed, the logs must be removed from the
grate.
3.
Install the circulator in the fireplace with the discharge duct facing the room. If the burner unit is already
installed, tilt the circulator forward so that the leg plate is perpendicular to the floor. After the circulator
leg plate is behind the burner unit, rotate the circulator to its normal position. (See Figure 1)
If the burner unit has not been installed, place the circulator in the rear of the fireplace facing forward.
(See Figure 1)
When properly installed, the circulator should be 1/8” from the rear of the grate and in the center of the
burner unit. If the leg assembly will not slide underneath the grate assembly due to the regulator, slide
the circulator slightly to one side and complete installation.
4.
This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard
and must be grounded in accordance with the National Electrical Code, ANSI/NFPA No. 70-1991.
5.
Route the electric cord on the bottom of the fireplace. Do not route the cord under the circulator.
6.
Position logs on the burner unit as described in the gas log instruction manual that was packaged with
your log set. If the entire log set had to be removed from the fireplace, reinstall according to the log set
instructions.
Wiring Diagram
Figure 1
Model SBF-100 & SBF-200 Circulator
Installation and Operating Instructions
11-1902