17
10.10
On installing the horizontal
fl
ue, determine the required length of the
outer air duct
by measuring the distance ‘L’ (
fi
gure 14) from the face of the external wall to the bottom
of the larger socket of the boiler’s elbow connecting collar.
NOTE:
The measurement for the inner
fl
ue duct will be ‘L’ + 10mm and the maximum length
of horizontal
fl
ue is 5.0m excluding the elbow connected to the boiler.
10.11
When
fi
tting the terminal measuring from the back of the terminal connection,
mark the distance ‘L’ onto the outer air duct. (
fi
gure 14)
10.12
Cut the
outer air duct only
to the required length ensuring that the cut is square and
free from burrs.
Figure 14
10.13
Measuring from the back of the terminal connection, mark distance ‘L’ + 10mm
(
fi
gure 15) onto the inner
fl
ue duct and cut the duct to size, ensuring that the cut is square
and free from burrs.
Figure 15
10.14
Pass the
fl
ue assembly through the wall and connect the assembly to the boiler,
ensuring that both the air and
fl
ue duct joints are fully pushed home into the connecting
elbow’s collar.
10.15
With the
fl
ue and joints secured
fi
t the
fl
ue trim to the external wall surface using
a suitable mastic.
NOTE
: Where there is no external access to the
fl
ue terminal the
fl
ue trim must be attached
to the
fl
ue assembly prior to passing the assembly through the wall.
10.16
The vertical system diagram is shown in
fi
gure 16.
NOTE:
Maximum vertical
fl
ue length is 5.0m.
Waste
L
External
wall face
L+20mm
L
L+10mm
Содержание SARGON 18S