background image

© 2003 DESA Specialty Products™

595-5291-04

OPERATION

Solar Powered
Motion Sensor Light

Model SL-7001

Features

• Turns on light when motion is detected.
• Automatically turns light off.
• Photocell keeps the light off during daylight hours.
• Battery Protection Circuitry. Protects against ex-

cessive overcharge and undercharge.

Requirements

• Do not turn the light on before the battery is fully

charged. Charge the battery by keeping the switch in
the OFF position and the solar collector pointed
directly at the noon sun for 3 sunny days. If not fully
charged, the unit will not work.

• When FULLY charged, the solar light will operate a

maximum of 15 days without sunlight. Actual operat-
ing time will vary depending upon how frequently the
light is triggered.

Mode:

On-Time:

Works:

Day

Night

Test

5 Sec.

x

x

Auto

30 Sec.

x

Light

TEST

OFF

AUTO

Put the sensor switch in the TEST
position.

AUTO

Battery

Case

Sensor

5 Mounting

Screws (2 sizes)

Put the sensor switch in the AUTO
position.

INSTALLATION

For best performance, mount the fixture about 8 feet
(2.4 m) above the ground.

Mount Solar Panel Base on a solid surface using

three tapered screws. Adjust the panel to point
directly at the noon sun. Avoid obstructions such as
trees or buildings that may block sun light. Allow for
enough wire to reach the case. Keep ball joint at
bottom.

Note: You will want to re-aim the solar panel as
the seasons change to keep it pointed directly at
the noon sun.

Three Mounting Holes for Solar Panel Base

Mount the Battery Case on a solid surface using

two round-head screws and the keyholes on the
back of the case.

Note:  When first turned on wait about 1 minute for the

circuitry to calibrate.

Light

Solar Panel

TEST

OFF

AUTO

3

/

4

"

TEST

This package includes:

Содержание SL-7001

Страница 1: ... Works Day Night Test 5 Sec x x Auto 30 Sec x Light TEST OFF AUTO Put the sensor switch in the TEST position AUTO Battery Case Sensor 5 Mounting Screws 2 sizes Put the sensor switch in the AUTO position INSTALLATION For best performance mount the fixture about 8 feet 2 4 m above the ground Mount Solar Panel Base on a solid surface using three tapered screws Adjust the panel to point directly at th...

Страница 2: ...nsor head clockwise 180 so the controls face down Control Switch Joint Clamp Plug the solar panel cable into the bottom of the battery case Allow the battery to charge with three days of sunshine before testing Aim Sensor Down for Short Coverage Aim Sensor Higher for Long Coverage SENSITIVITY OFF TEST AUTO NOTE Sensor has a 1 minute warm up period before it will detect motion When switching modes ...

Страница 3: ...a soft cloth and warm water Do not hose spray Keep the collector clear of snow and leaves Make sure trees and other objects do not block sunlight from the panel If not to be used for several weeks turn the unit OFF Store it with the panel connected and where the panel can gather sunlight Solar collection is only effective in direct sunlight Every hour the light is on requires a minimum of 16 hours...

Страница 4: ...LL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY WARRANTY REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE AND SPECIFICALLY IN LIEU OF ALL SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF DESA SPECIALTY PRODUCTS FOR ANY ...

Страница 5: ...a posición TEST AUTOMÁTICA Caja para la batería Detector 5 tornillos de montaje 2 tamaños Ponga el interruptor del detector en la posición AUTO MÁTICA INSTALACIÓN Para un mejor rendimiento monte la unidad cerca de 2 4 m 8 pies desde el piso Monte la base del panel solar sobre una superficie sólida usando tres tornillos cónicos Acomode el panel de manera que apunte directamente al sol del mediodía ...

Страница 6: ... abajo Interruptor del control Sujetador de la unión Enchufe el cable del panel solar en la parte inferior de la caja de la batería Deje que la batería se carguedurantetresdíasdesolantesdeprobarla Apunte el detector hacia abajo para una cobertura pequeña Apunte el detector hacia arriba para una cobertura grande SENSITIVITY OFF TEST AUTO NOTA El detector tiene 1 minuto de calentamiento antes de det...

Страница 7: ...de carros Apunte de nuevo el detector 2 La sensibilidad es muy alta Reduzca la sensibilidad ESPECIFICACIONES Alcance Hasta 15 2 m varía de acuerdo a la temperatura donde se encuentre Ángulo de detección Hasta 100 Lámpara Halógena de 15 vatios 6 voltios Tipo de batería Batería sellada de plomo 6 V 5 0A Hr Duración 30 Segundos re activable Duración con carga completa Hasta 1 hora Cambielalámparacone...

Страница 8: ...antía Los Servicios no autorizados o modificaciones del producto o de cualquier componente que se provee invalidarán esta garantía en su totalidad Esta garantía no incluye reembolso por inconveniencia instalación tiempo de montaje pérdida por uso o servicio no autorizado Esta garantía cubre solamente los productos ensamblados por DESA Specialty Products y no se extiende a otros equipos o component...

Отзывы: