7
206546-02
TESTING AND ADJUSTMENTS
Initial Setup
The TEST mode overrides the photocell (daylight shutoff
feature) and allows the light fixture to be tested day or night
when the ON-TIME switch is in the TEST position. The
light will stay on for 5 seconds after all motion has stopped.
Maximum Range
Maximum
Coverage Angle
(Top View)
Sensor Controls
Final Setup
1. Adjust the sensitivity (SENS) to increase or decrease
the range as needed. Too much sensitivity may cause
false triggering due to heat sources in the coverage area
(see Testing and Adjustments or Troubleshooting section).
2. Set the amount of ON-TIME you want the light to
stay on after motion is detected (1, 5, or 10 minutes).
3. Set the DualBrite® switch to off, 3 hours, 6 hours,
or dusk-to-dawn.
4. Caulk around fixture base with silicone weather seal-
ant after all Testing and Adjustments are complete.
1. Turn the DualBrite control to OFF.
2. Set the ON-TIME control to TEST.
3. Turn on the circuit breaker or fuse and the light switch.
4. Allow the sensor to completely warm up (90 seconds)
before beginning the setup process.
5. Perform a walk test. Walk in an arc across the front of
the sensor.
TEST 1 5 10
MINUTE
OFF 3 6 DUSK TO
HOUR DAWN
Rotating Sensor Head to Change Coverage Area
6. Move the sensor head left or right to change the coverage
area.
Note:
Grasp the sensor only as shown and turn
the entire sensor.
Any other method may damage
the sensor. Do not force it past the stops.
15
0°
150
°
30 ft . (9 .1 m)
6 ft .
(1 .8 m)
150°
Caulking Around Fixture Base